Altronix ACMS8 Series Скачать руководство пользователя страница 2

 

- 2 - 

ACMS8/CB Sub-Assembly

Overview:

Altronix ACMS8(CB) Access Power Controller’s dual input design allows power to be steered from two (2) 
independent low voltage 12 or 24VDC power sources to eight (8) independently controlled fuse (ACMS8) or 
PTC (ACMS8CB) protected outputs. Power outputs of ACMS8(CB) can be converted to dry form “C” contacts. 
Outputs are activated by an open collector sink, normally open (NO), normally closed (NC) dry trigger input, 
or wet output from an Access Control System, Card Reader, Keypad, Push Button, PIR, etc. ACMS8(CB) will 
route power to a variety of access control hardware devices including Mag Locks, Electric Strikes, Magnetic 
Door Holders, etc. Outputs will operate in both Fail-Safe and/or Fail-Secure modes. The FACP Interface enables 
Emergency Egress, Alarm Monitoring, or may be used to trigger other auxiliary devices. The fire alarm discon-
nect feature is individually selectable for any or all of the eight (8) outputs. The spade connectors allow you to 
daisy chain power to multiple ACMS8(CB) modules. This feature allows you to distribute the power over more 
outputs for larger systems.

Specifications:

Power Supply Input Options:

•  Input 1 and Input 2 voltage range:
 

ACMS8:  

5VDC to 24VDC, up to 10A each,

    

20A 

total 

input.

 

ACMS8CB:  5VDC to 24VDC up to 10A each,

    

16A 

total 

input.

•  Eight (8) trigger inputs: 
    a) Normally open (NO) inputs. 
    b) Normally closed (NC) inputs.
    c) Open collector sink inputs.
    d) Wet Input (5VDC - 24VDC) with 10K resistor
    e) Any combination of the above. 

Outputs:

• 

ACMS8: 

Fuse protected outputs rated @ 2.5A 

       

per output, non power-limited. 

       

Total output 20A max. 

       

Do not exceed the individual 

    

power 

supply 

ratings.

 

ACMS8CB:  PTC protected outputs rated @ 2A 

       

per output, Class 2 power-limited. 

       

Total output 16A max.

       

Do not exceed the individual 

    

power 

supply 

ratings.

  Total output current should not exceed max. current
  rating of the power supplies employed on each input.
 See 

Maximum Output of Altronix Power Supplies.

•  Eight (8) selectable independently controlled 
  outputs or eight (8) indepently controlled 
  Form “C” relay outputs (see below for ratings): 
    a) Fail-Safe and/or Fail-Secure power outputs. 
    b) Form “C” relays rated @ 2.5A.
    c) Auxiliary power outputs (unswitched).
    d) Any combination of the above. 
•  Individual outputs may be set to OFF position for 
  servicing (output jumper set to middle position).
  Does not apply to Dry Contact applications.

Outputs 

(cont’d)

:

•  Any of the eight (8) fuse/PTC protected power 
  outputs are selectable to follow power Input 1 or 
  Input 2. Output voltage of each output is the same 
  as the input voltage of the input selected. 
•  Surge suppression.

Fire Alarm Disconnect:

•  Fire Alarm disconnect (latching or non-latching) is 
  individually selectable for any or all of the 
  eight (8) outputs.
  Fire Alarm disconnect input options: 
    a) Normally open [NO] or normally closed [NC] 
      dry contact input. Polarity reversal input from 
   FACP 

signaling 

circuit.

•  FACP output relay [NC] contact or provides 
  10k resistance with [EOL JMP] intact.

Outputs Ratings:

 

ACMS8:  

Fuses are rated 2.5A each.

 

ACMS8CB:  PTCs are rated 2A each.

Fuse Ratings:

•  Main input fuses rated @ 10A/32V each.

LED Indicators:

•  Red LEDs indicate outputs are triggered.
•  Blue LED indicates FACP disconnect is triggered.

Environmental:

•  Operating temperature: 0ºC to 49ºC ambient.
•  Humidity: 20 to 93%, non-condensing.

Mechanical:

•  Board Dimensions (W x L x H approximate): 
  7.65” x 4.125” x 1.25” 
  (194.3mm x 104.8mm x 31.8mm).
•  Product weight (approx.): 0.7 lb. (0.32 kg).
•  Shipping weight (approx.): 0.95 lb. (0.43 kg).

Содержание ACMS8 Series

Страница 1: ...Rev 102617 ACMS8 Series Sub Assembly Access Power Controllers Installation Guide Models Include ACMS8 Eight 8 Fuse Protected Outputs ACMS8CB Eight 8 PTC Protected Outputs More than just power TM ...

Страница 2: ... supply ratings ACMS8CB PTC protected outputs rated 2A per output Class 2 power limited Total output 16A max Do not exceed the individual power supply ratings Total output current should not exceed max current rating of the power supplies employed on each input See Maximum Output of Altronix Power Supplies Eight 8 selectable independently controlled outputs or eight 8 indepently controlled Form C ...

Страница 3: ...tively the corresponding output fuse 1 8 can be removed ACMS8 only Connect negative of the power supply directly to the locking device Connect the positive of the power supply to the terminal marked C For Fail Safe operation connect the positive of the device being powered to the terminal marked NC For Fail Secure operation connect the positive of the device being powered to the terminal marked NO...

Страница 4: ...triggered by the unit s dry contact output to the terminals marked NC and C When EOL JMP is kept intact the output is of 0 Ohm resistance in a normal condition When EOL JMP is clipped a 10k resistance will be passed to next device when in a normal condition LED Diagnostics ACMS8 and ACMS8CB Access Power Controller LED ON OFF LED 1 LED 8 Red Output relay s de energized Output relay s energized FACP...

Страница 5: ...P3 INP4 INP5 INP6 INP7 INP8 3 3 3 3 3 3 3 3 3 ACMS8 ACMS8CB Altronix Corp Brooklyn NY 11220 1 2 3 4 ON 3 PWR1 PWR2 COM COM 5 6 7 8 1 2 3 4 5 6 7 8 ON ON ON PWR2 OFF PWR1 PWR2 NC RST EOL F R C GND GND F R NO C NC COM NO C NC COM Output 1 Output 2 NO C NC COM NO C NC COM Output 3 Output 4 NO C NC COM NO C NC COM Output 5 Output 6 NO C NC COM NO C NC COM Output 7 Output 8 OUT1 RISK OF FIRE REPLACE FU...

Страница 6: ...1 of ACMS8 CB Thus Input 1 of ACMS8 CB is 24VDC from power supply and Input 2 is determined by VR6 s settings 5VDC or 12VDC 6 Complete steps 4 10 pgs 3 4 Power Input Output Input 24VDC 1 75A Output 5VDC 6A Input 24VDC 3 5A Output 12VDC 6A Output 5VDC or 12VDC regulated output Output rating 6A max Surge suppression LED Indicators Input and output LEDs Electrical Operating temperature 0ºC to 49ºC am...

Страница 7: ...ooklyn NY 11220 1 2 3 4 ON 3 PWR1 PWR2 COM COM 5 6 7 8 1 2 3 4 5 6 7 8 ON ON ON PWR2 OFF PWR1 PWR2 NO C NC COM NO C NC COM Output 1 Output 2 NO C NC COM NO C NC COM Output 3 Output 4 NO C NC COM NO C NC COM Output 5 Output 6 NO C NC COM NO C NC COM Output 7 Output 8 FACP FACP EOL JMP NC RST EOL F R C GND GND F R NC NO C Normally Open N O Door Releasing Device Access Control Panel Output Relay Mag ...

Страница 8: ...ngle Reset FACP FACP NC RST EOL F R C GND GND F R FACP FACP Jumper Jumper NC RST EOL F R C GND GND F R EOL JMP EOL JMP FACP FACP NC RST EOL F R C GND GND F R FACP FACP Jumper NC RST EOL F R C GND GND F R EOL JMP EOL JMP N O Switch FACP FACP NC RST EOL F R C GND GND F R FACP FACP NC RST EOL F R C GND GND F R EOL JMP EOL JMP N O Switch N O Switch Fig 9 Daisy chaining one or more ACMS8 units EOL Jump...

Страница 9: ...n Latching FACP FACP N O Switch EOL NC RST EOL F R C GND GND F R Hook Up Diagrams FACP FACP Jumper 10K EOL NC RST EOL F R C GND GND F R Fig 12 Normally Closed trigger input Non Latching FACP FACP Jumper 10K EOL NC RST EOL F R C GND GND F R Fig 13 Normally Closed trigger input Latching FACP FACP NC RST EOL F R C GND GND F R N O Switch Jumper EOL Fig 14 Normally Open trigger input Non Latching FACP ...

Страница 10: ... 10 ACMS8 CB Sub Assembly Notes ...

Страница 11: ...ACMS8 CB Sub Assembly 11 Notes ...

Страница 12: ...not responsible for any typographical errors 140 58th Street Brooklyn New York 11220 USA phone 718 567 8181 fax 718 567 9056 website www altronix com e mail info altronix com Lifetime Warranty Made in U S A IIACMS8 ACMS8CB C20R MEMBER Notes ...