6600/Rev/Mar.2021
Page 10
Altronic Research Inc.
circuit, the alarm circuit, and RF source(s). Turn the user supplied main power switch
"ON" and enable the transmitter. Operate the transmitter as desired. To stop operation, it
is necessary to first turn off the transmitter. The fan may continue to run for some time.
This depends upon the power level at which the load was operating and upon the ambient
air temperature. This feature is necessary to prevent damage to the load. 6600 Series
Coaxial Loads with fans operates in "Standby" or "Reject" mode with the blower off.
1-7.
Operating and Adjustment Controls.
No field adjustments are necessary or possible.
1-8.
Electrical Description.
Models sold with fans contains a 50-ohm non-reactive resistor
assembly capable of dissipating a total of their rated watts of applied electrical energy at
frequencies between DC and 110MHz with a maximum VSWR of 1.10 to 1. No provisions
are made for tuning the resistor assembly and all operating controls relate to the operation
of the optional fan assembly. The fan control circuit consists of two switches wired in
parallel to control the fan motor. Power is supplied to the fan whenever the equipment is
attached to the correct power supply and the user supplied main power switch is "ON" and
the fan thermal switch senses a temperature equal to or greater than 120
°
(
±
7
°
)F. When
sold with fans the transmitter interlock circuit consists of one normally closed 250
°
F
thermal switch wired to terminals (C,D) on the Amphenol four pin cylindrical twist lock
connector located on the front panel of the unit. There is no interlock circuit provided for
units sold without fans. The alarm circuit consists of one normally closed 372°F thermal
switch wired to terminals (A,B) on the Amphenol four pin cylindrical twist lock connector.
1-9.
Operator Training.
The operator of this equipment must have the following
skills/knowledge:
An understanding of the purpose of the equipment;
An understanding of the principles of operation of the equipment;
An understanding of the normal operating procedures for the equipment;
An understanding of the normal and abnormal indications which may be presented at
the control point;
The proper procedures for starting, using and stopping the equipment under normal
conditions;
The proper procedure for stopping the equipment under abnormal or emergency
conditions;
The proper procedure to lock out and mark controls prior to allowing or commencing
maintenance on the equipment;
The proper procedure to obtain clearance to remove lockouts and out-of-service
marks and return the equipment to normal service.