13
unit liquid inlet for any obstructions.
③
Check the strainer to ensure the tubing is under the liquid level.
④
Re-start again the Air drawing operation.
Caution:
1.
In case the Electrolysis agent liquid tank is located higher than the
unit, the tank should be moved to a lower position than the unit.
OPERATIONAL STEPS:
How to produce strong electrolyzed water
●
Connect the grounding wire and connect the AC cable connect to the wall
power outlet and turn on power switch located backside.
Warning:
Make sure the grounding wire is correctly secured
otherwise there is a possibility of an electrical shock
hazard.
Do not handle the AC cable with wet hands otherwise
there is a possibility of an electrical shock hazard.
After the Power is turned on a display will appear as
Turn the diverter position horizontal then turn on tap water. ● Conduct the air drawing
operation. (Refer to air drawing operation on the previous page.)
1.
Continuance Mode
・
Press Continuance Mode button or remote switch
(option). Process lamp will turn on and start strong
electrolysis processing.
. Press again the Continuance Mode button or remote
switch (option) for process stop.
2.
Timer Mode
・
Please set your required process value by value
button▲▼. (minimum of 0.5 liter, maximum of 60
liters)
・
Press Timer Mode button. Process lamp will turn on and start strong electrolysis
processing.