32
Stabilisers and Outriggers - Mobile Towers 3T method
Stabilisers
Stabiliser Dimensions
Outriggers
Attach one stabiliser to each corner of the tower as shown. Ensure stabiliser feet are equally
spaced to form a square. SP10 and SP15 telescopic stabilisers must always be fully extended.
Position the lower clamp so that the lower arm is as close to the horizontal as possible. Adjust the
position of the top clamp to ensure the stabiliser foot is in firm contact with the ground. Ensure
clamps are secure.
Stabilisers are used when the tower is to be moved occasionally, frequent movement will require
mobile outriggers.
When moving the tower, adjust the top clamps to lift the four stabiliser feet a maximum of 25mm
off the ground and then unlock the castor brakes. After moving, ensure all four stabiliser
feet are repositioned in firm contact with the ground.
For information on mobile outriggers please consult your supplier.