16
Assembly transport wheels
1. Secure the wheel axle (5) using the two hexagon head
screws M6x30 and install the cotter pins.
2
Secure the cotter pins against dropping out by
bending their ends using nippers and slide the washers (Ø
15.5) on the wheel axle.
3. Slide the wheels (6) and the washers on the wheel axle.
Secure the wheels using the securing pins (7).
L
L
o
o
c
c
a
a
t
t
i
i
o
o
n
n
o
o
f
f
t
t
h
h
e
e
a
a
i
i
r
r
d
d
e
e
h
h
u
u
m
m
i
i
d
d
i
i
f
f
i
i
e
e
r
r
Location
If possible, the air dehumidifier should be placed in the middle
of the room in order to have a good air circulation in the whole
room.
If this is not possible, locate the air dehumidifier so that air can
be sucked and discharged unhindered.
Keep a minimum distance of 10 cm to walls.
Place the air dehumidifier
⇒
horizontally to ensure that the condensed water can flow off
unhindered
⇒
away from a heat source (e.g. a radiator).
L
Make sure that windows and doors of the room to be
dehumidified are closed.
Electric supply
Compare the voltage listed on the device’s type plate, e.g. 230
V / 50 Hz, with the mains voltage and connect the air
dehumidifier to a suited and and properly earthed electrical
socket.
Use an electrical socket with a rated voltage of 230 V with a
fault-current circuit breaker (30 mA).
Power system fuse protection
10 A
S
S
t
t
a
a
r
r
t
t
-
-
u
u
p
p
Before starting up
Did you transport the air dehumidifier in horizontal position or at
an angle large than 45°?
L
Allow the device to stand in vertical position for at least
one hour.
L
Notes
4.
The air dehumidifier will not work if the set humidity value is
higher than that of the environment.
5.
Only use the air dehumidifier at a room temperature
between 5 °C and 32 °C. The air dehumidifier will not
function out of this range.
6.
Do not operate the air dehumidifier in heavily dust-laden or
chloric atmospheres.
7.
Once the compressor has been started the fan motor and
the compressor must run for at least 3 minutes during
dehumidification. To prevent damages to the compressor,
you should wait for 3 minutes after a shut-down of the air
dehumidifier before you restart the device.
8.
If the room temperature is under 10 °C and the relative
humidity of the ambient air is rather low an operation of the
air dehumidifier will not be necessary.
Содержание LDH 500
Страница 34: ...34 L L L 16...
Страница 35: ...35 IEC 60245 H 07 RN F 1 5 25 2 5 25 PVC 30 mA 2 5 C L 1 2 2 M6x40 A 6 4 L 3 4 2 3...
Страница 36: ...36 6 M 6x40 A 6 4 L 1 5 M 6 x 30 2 15 5 3 6 7 10 cm L 230 V FI 30 mA 10 A 45 L...
Страница 38: ...38 20 C 5 C L 45 E4 5 1 2 3 8 4 5 6 E4 1 2 9 3 4 12 5 L...
Страница 39: ...39 L 1 2 10 40 C 1 2...
Страница 40: ...40 a 5 C 32 C b 30 c 10 cm a b a b a b L L 2 E3 E4 E5 L E3 E5...
Страница 143: ......