Pos. No. 

Article No.  

Description 

No. 

27 647702 

Hose 

nipple 

28 659100 

Threaded 

connection 

29 

354200 

Hose for injector rinsing 

30 

530900 

Solenoid valve 1/4” EVI 3 

 

531700 

Coil 24 V 50 Hz, 9 W 

 

532100 

Coil 220 V 50 Hz, 9 W 

31 0605446 

Special 

beending 

32 646400 

3/4” 

Union 

33 

531300 

Solenoid valve 3/4" EVI 20 

 

310403 

Coil 24 V 50 Hz,  

34 0605447 

Outlet 

water 

35 

639100 

Packing for air nozzle 

36 

64030000 

Air nozzle 450 l/min. (Ø3,5mm.) 

37 

640000 

Non-return valve for air 

38 

638500 

Air fittings, angle 1/4" x 8 mm 

39 

635650 

Air filter/regulator w/ pressure gauge 

40 

639700 

Spring ring for injector 

41 

640600 

O-ring for injector housing 

42 0605448 

Foam 

outlet 

43 354400 

Clamp 

44 920500 

Socket 

1/2” 

45 0605494 

Distance 

pipe 

46 

531101 

Solenoid valve 1/2”  

  

Coil 

47 0603048 

Union 

1/2” 

48 

0608061 

Fittings for air 

 

Содержание PZC Classic

Страница 1: ...25 10 2004 0617551 UK Vers 1 1 Directions for Use for Automatic Pump Station PZC Classic...

Страница 2: ...21 10 2004 ALTO Danmark A S...

Страница 3: ...r connection 2 2 4 Connection of detergents 3 2 5 Layout drawing for pump station PZC 4 3 Directions before operation Automatic cleaning 8 4 Security devices 10 5 Regular service and control 11 6 Inte...

Страница 4: ...21 10 2004 ALTO Danmark A S...

Страница 5: ...nimum requirement for maintenance and repair work The combination of a centrifugal pump and an injector offers the possibilities of automatic and manual a foam spreading of detergents b rinsing off wi...

Страница 6: ...necessarily long supply pipes should be avoided low resistant ball valves should be used fittings with high pressure loss should be avoided f On pipe mounting care should be taken that no air locks ar...

Страница 7: ...ed air connection for pump station PZC O on the layout drawing on page 4 2 4 Connection of Detergents a place the can with the suitable detergent in the can holder b Control the detergent hose filter...

Страница 8: ...ss gauge reduction valve air B Ball valve for water J Solenoid valve for air C Strainer K Dosing valve for detergent D Flow switch L Filter reduction valve for external air E Pump M Foam outlet F Exte...

Страница 9: ...e reducing valve for air I on the layout drawing on page 4 Check the air pressure on the pressure gauge for air I on the layout drawing on page 4 NOTE When setting the reducing valve for air carefully...

Страница 10: ...s the pump as soon as a flow takes place in the flow switch If all valves are closed and there is no flow in the flow switch the flow switch disconnects the pump after the time interval entered into t...

Страница 11: ...ucation and experience have sufficient knowledge of low pressure cleaners or similar equipment and who are familiar with the state work security regulations accident preventing regulations lines and g...

Страница 12: ...ion of rotation of pump z Connect the pump correctly Flow switch defective z Call for skilled persons Pressure gauge defective z Replace pressure gauge Insufficient water supply z z Ensure water suppl...

Страница 13: ...ore switching on again check cause of disconnection The machine does not build up pressure The program does not function correctly No water supply Direction of rotation of pump not correct Check the p...

Страница 14: ...cient air supply to the plant Incorrect air pressure on the plant Too high air pressure in the injector read pressure on pressure gauge Incorrect nozzles mounted Ensure sufficient air supply 450 l min...

Страница 15: ...etergent The concentration of the detergent is set too low Clean the filter Put the hose into the can Set dosing valve for detergent on pos 4 No pressure air in the plant Inlet valve for pressure air...

Страница 16: ...Non return valve 5 Pressure gauge water 16 Solenoid valve air external air 6 Non return valve water 17 Micro filter 7 Solenoid valve water outlet 18 Filter regulator for external air 8 Solenoid valve...

Страница 17: ...21 10 2004 ALTO Danmark A S 8 Type Plate 1 Producer 2 Serial number 3 Type 4 Date 5 Order number 6 Maximum pressure 7 Voltage 8 Frequency 9 Water volume 10 Consumption of air 11 Maximum temperature...

Страница 18: ...trol voltage Security of electrical wiring Electrical cable Weight Total dimension H x W x D Max air inlet pressure Min inlet flow for start of plant 25 bar 12 bar inlet pressure 25 bar 10 100 l min 4...

Страница 19: ...All hoses rubber parts or synthetic materials natural wear and tear as well as damage caused by careless and inappropriate treatment including transport damage are not covered by the guarantee Furthe...

Страница 20: ...21 10 2004 ALTO Danmark A S 11 Material and Spare Parts List...

Страница 21: ...0 Hz 1 11 358310 Outlet coupling for pump 1 12 659000 Pressure gage for water 1 13 600400 Non return valve 1 14 354700 Distance pipe 3 4 x 1 2 w pipe branch 1 15 531100 Solenoid valve 1 2 EVI 10 1 16...

Страница 22: ...3 4 EVI 20 1 310403 Coil 24 V 50 Hz 1 34 0605447 Outlet water 1 35 639100 Packing for air nozzle 1 36 64030000 Air nozzle 450 l min 3 5mm 1 37 640000 Non return valve for air 1 38 638500 Air fittings...

Страница 23: ...escription No 49 0608071 Reducer 12 8 1 50 0608060 Tee air fittings 1 51 0605449 Filter regulator for air 1 52 0608057 Air fittings angle 1 2 x12 3 53 0605459 Micro filter 1 54 0608061 Fittings for ai...