MN-28648 • Rev 3 (11/14) • AR-6G Rotisserie Operation & Care Manual • 10
I N S T A L L A T I O N
A I R S U P P L Y
AIR SUPPLY
Installation of this appliance must include a
provision for an adequate flow of fresh air for gas
combustion. This requirement must be observed
by the installer as well as the operator. The rear of
the appliance provides air supply access for gas
combustion and must be kept clear at all times
.
Make certain the installation maintains adequate air
ventilation to provide cooling for electrical and gas
components. The area around the appliance should
be clear of any obstructions which might retard the
flow of cooling air. Failure to observe this caution
may result in damage to the control components and
will void the warranty.
Local and the National Fuel Gas Code provide
rules for determining the amount of fresh air
necessary for combustion and ventilation of
commercial cooking appliances. The codes will help
determine if additional outside air may be necessary
to meet health and safety regulations.
AIR ADJUSTMENTS
The appliance can be field converted from one type of gas
to another (natural gas to propane or vice versa).
After taking the necessary safeguards for the gas circuit
by employing the shut-off valve located at the rear of the
appliance, and disconnect the appliance from the electric
supply. Open the right-hand machine compartment.
Replace orifices as shown in chart.
Replace valves located under access panel.
Set manifold pressure as shown in chart.
If any gas fittings are loose or have been replaced, perform
the following test:
❑
Use a soap and water solution to check all fittings for
leaks. Brush solution on all joints or areas where a leak
may be present. If bubbles appear, re-tighten the fitting
and recheck. If bubbles persist, replace the fitting.
Always reconnect the gas line and inspect for leaks before
replacing access panels.
NATURAL
PROPANE
Top Orifice
OR-28127
# 29
OR-28132
# 43
Middle Orifice
OR-28128
# 20
OR-28191
# 41
Bottom Orifice
OR-28129
# 1
OR-28130
# 38
Manifold Pressure
5.0 µ/wc
10.0 µ/wc
C A U T I O N
DO NOT USE CIRCULATING FANS
ON THE FLOOR. FLOOR FANS WILL
AFFECT BURNER OPERATION.
OPTIONAL CONVERSION KITS
Natural Gas to Propane
5008903
Propane to Natural Gas
5008904
C A U T I O N
CONVERSIONS MUST BE
PERFORMED BY A CERTIFIED
SERVICE TECHNICIAN QUALIFIED TO
WORK ON GAS APPLIANCES.
C A U T I O N
MAKE CERTAIN THE AREA AROUND
THE REAR OF THE APPLIANCE IS
KEPT CLEAR OF OBSTRUCTIONS TO
ALLOW A CONTINUOUS SUPPLY OF
FRESH AIR FOR GAS COMBUSTION.