SAFETY INSTRUCTIONS 

 
 
INSTRUCTIONS  PERTAINING  TO  A  RISK  OF 
FIRE,  ELECTRICAL  SHOCK,  OR  INJURY  TO 
PERSONS FOR SS-UV3 SERIES LED LIGHTING 
FIXTURES. 
 

 
WARNING!  -  TO  REDUCE  THE  RISK  OF  FIRE, 
ELECTRIC  SHOCK,  OR  INJURY  TO  PERSONS, 
FOLLOW 

THESE 

IMPORTANT 

SAFETY 

INSTRUCTIONS: 
 
CAUTION:  RISK  OF  ELECTRIC  SHOCK,  DO 
NOT USE EXTENSION CORD NEAR WATER OR 
WHERE  WATER  MAY  ACCUMULATE.  KEEP 
LAMP AT LEAST 16 FEET AWAY FROM POOLS 
AND  SPAS.  KEEP  PLUGS  AND  RECEPTACLES 
DRY.  FOR  USE  ONLY  IN  GFCI  PROTECTED 
CIRCUITS. 
 
1) 

Turn off, unplug power, and allow fixture 
to cool before cleaning or servicing.  

 
2) 

Ensure that fixture is properly grounded. 

 
3) 

Ensure  that  heat  sink  fins  are  not 
obstructed. 

 
4) 

Do not look directly at lighted LEDs. 

 
5) 

Keep away from flammable materials.  

 
6) 

No  user  serviceable  parts  inside.  
Replace entire LED assembly. 

 
7) 

Do not touch the LEDs at any time. Use 
a soft lint-free cloth to clean lens. Do not 
use  solvents  to  clean.  Use  cloth 
dampened  with  water.  Allow  to  dry 
completely before reenergizing. 

 
8) 

Do not operate the unit with a missing or 
damaged lens. 

 
 

----------SAVE THESE INSTRUCTIONS!----------- 
 
 
 
 
 
 
 
 
 

 

 
 
 
 
INSTRUCTIONS DE SÛRETÉ 

 
 
LES INSTRUCTIONS AU SUJET D'UN 
RISQUE D'INCENDIE LE CHOC 
ÉLECTRIQUE, OU LA BLESSURE AUX 
PERSONNES POUR SS-UV3 APP AREILS 
D'É CLAIR AGE DE LED.

 

 

 
AVERTISSEMENT!  -  POUR  RÉDUIRE  LE 
RISQUE  D'INCENDIE,  LE  CHOC  ÉLECTRIQUE, 
OU  LA  BLESSURE  AUX  PERSONNES,  SUIVRE 
CES 

INSTRUCTIONS 

DE 

SÉCURITÉ   

IMPORTANTES

 

ATTENTION : LE RISQUE DE DÉCHARGE 
ÉLECTRIQUE, N'EMPLOIENT PAS LA CORDE 
DE PROLONGATION PRÈS DE L'EAU OU OÙ 
L'EAU PEUT S'ACCUMULER. GARDEZ LA 
LAMPE AU MOINS 16 PIEDS À PARTIR DES 
PISCINES ET DES STATIONS THERMALES. 
MAINTENEZ LES FICHES ET LES DOUILLES 
SÈCHES. POUR L'USAGE SEULEMENT DANS 
DES CIRCUITS PROTÉGÉS PAR GFCI. 
 
 
1)  

Éteignez,  débranchez  la  puissance,  et 
permettez  au  montage  de  se  refroidir 
avant le nettoyage ou l'entretien.  

 
2) 

Assurez-vous  que  le  montage  est 
correctement relié à la terre. 

 

3) 

Assurez-vous que ailerons de radiateur 
ne sont pas obstruées. 

 
4) 

Ne  regardez  pas  directement  la  LED 
allumée. 

 
5) 

S'éloigner des materiaux inflammables. 

 
6) 

Aucunes  pièces  utiles  d'utilisateur  à 
l'intérieur. Remplacez la LED entière. 

 
7) 

Ne touchez pas la LED à tout moment. 

 

Employez  un  chiffon  non  pelucheux 
mou pour nettoyer l'objectif. N'employez 
pas  les  dissolvants  pour  nettoyer.peut 
employer 

le 

tissu 

humecté 

de 

l'eau.laissez sécher complètement avant 
de reenergizing.  

 
8) 

Ne  pas  faire  fonctionner  l'appareil  avec 
un diffuseur antérieur ou une lampe. 

 
 

----------GARDER CES INSTRUCTIONS!----------

 

Содержание SS-UV30

Страница 1: ...D Series Manual Installation and Instruction 2010 Altman Lighting Inc 57 Alexander Street Yonkers New York 10701 U S A Phone 914 476 7987 Fax 914 963 7304 Specifications are subject to change without notice Copyright 2010 Rev 2010 08 30 www altmanlighting com ...

Страница 2: ...N RISQUE D INCENDIE LE CHOC ÉLECTRIQUE OU LA BLESSURE AUX PERSONNES POUR SS UV3 APPAREILS D É CLAIRAGE DE LED AVERTISSEMENT POUR RÉDUIRE LE RISQUE D INCENDIE LE CHOC ÉLECTRIQUE OU LA BLESSURE AUX PERSONNES SUIVRE CES INSTRUCTIONS DE SÉCURITÉ IMPORTANTES ATTENTION LE RISQUE DE DÉCHARGE ÉLECTRIQUE N EMPLOIENT PAS LA CORDE DE PROLONGATION PRÈS DE L EAU OU OÙ L EAU PEUT S ACCUMULER GARDEZ LA LAMPE AU ...

Страница 3: ... engine incorporating Nichia 365nm SMD LEDs and an on board power supply The LED substrate is coupled to a highly efficient circuit board and heat sink cooling system for prolonged life of the LEDs The fixture can be ceiling mounted to a pipe stand mounted or floor mounted All components and electrical devices are ETL or UL Listed or Recognized A safety cable is provided for use when securing the ...

Страница 4: ...ure the Yoke to the stand with a bolt and washer For floor mounting adjust the yoke to the bottom so the fixture frame and the yoke securely hold the UV fixture Connecting power to the fixture Plug the fixture into a grounded receptacle connected to a circuit breaker Connect DMX signal to the fixture Focusing the fixture With the fixture energized point the unit in the direction of the object to b...

Страница 5: ...RDM protocols including Wybron Responder System i 8 16 bit DMX 512 control for smoother UV dimming and UV fades i Strobe Effect of UV LEDs i Long life UV LEDs with no ballast or short life lamp changes i On board power supply microprocessor controller and current drivers i Feed thru DMX RDM data with a maximum total run of 1000 feet i Push button addressing i Stand Alone Pre Programmed Operational...

Страница 6: ...from a remote unit will overwrite local DMX setting PERSONALITIES There are 8 different personalities Each personality is made up of 3 settings RESOLUTION 8 Bit 16 Bit MASTER On Off and SMOOTHING On Off which are explained in greater detail below The current active Personality is displayed for about 1 second during power up The format is Pxx where xx is replaced by the active personality 01 08 To ...

Страница 7: ...sonality 04 8 Bit Master ON Smoothing ON uses 5 DMX channels Channel order is UV1 UV2 UV3 N A M 605 Personality 05 16 Bit Master OFF Smoothing OFF uses 8 DMX channels Channel order is UV1 uv1 UV2 uv2 UV3 uv3 N A n a 606 Personality 06 16 Bit Master OFF Smoothing ON uses 8 DMX channels Channel order is UV1 uv1 UV2 uv2 UV3 uv3 N A n a 607 Personality 07 16 Bit Master ON Smoothing OFF uses 10 DMX cha...

Страница 8: ...MX cable to all synchronize Set other units to DMX Channel 001 Note Do not use the Stand Alone Effects while connected to a control console or a conflict will result Unless the Master Slave mode has been disabled See instructions below Key 1 UV1 UV LED Module One Facing UV3 Left most LED light module 2 UV2 UV LED Module Two Facing UV3 Center LED light module 3 UV3 UV LED Module Three Facing UV3 Ri...

Страница 9: ...h any button to turn on display Locked Mode To Lock or unlock the buttons Wait a few seconds until the display goes blank press and hold the ONES button press and hold the HUNDREDS button release the ONES button release the HUNDREDS button Display will show Loc for a moment and then blink Buttons will have no effect until they are unlocked Master and Slave Mode To Turn On or Off the MASTER Wait a ...

Страница 10: ...I N S T A L L A T I O N A N D I N S T R U C T I O N M A N U A L 10 www altmanlighting com 2010 Altman Lighting Inc 57 Alexander Street Yonkers New York 10701 U S A Phone 914 476 7987 Fax 914 966 1980 ...

Страница 11: ...A N D I N S T R U C T I O N M A N U A L 11 Altman Lighting Inc is a subsidiary of Altman Stage Lighting Co Inc Specifications are subject to change without notice Copyright 2010 Rev 2010 11 05 PN 49 0XXX www altmanlighting com ...

Отзывы: