Altman Spectra-PAR SS-PAR-100 Скачать руководство пользователя страница 2

 

 

 

2

SAFETY INSTRUCTIONS 

 
 
INSTRUCTIONS  PERTAINING  TO  A  RISK  OF 
FIRE,  ELECTRICAL  SHOCK,  OR  INJURY  TO 
PERSONS  FOR  SS-PAR-100  SERIES  LED 
LIGHTING FIXTURES. 
 

 
WARNING!  -  TO  REDUCE  THE  RISK  OF  FIRE, 
ELECTRIC  SHOCK,  OR  INJURY  TO  PERSONS, 
FOLLOW 

THESE 

IMPORTANT 

SAFETY 

INSTRUCTIONS: 
 
CAUTION:  RISK  OF  ELECTRIC  SHOCK,  DO 
NOT USE EXTENSION CORD NEAR WATER OR 
WHERE  WATER  MAY  ACCUMULATE.  KEEP 
LAMP AT LEAST 16 FEET AWAY FROM POOLS 
AND  SPAS.  KEEP  PLUGS  AND  RECEPTACLES 
DRY.  FOR  USE  ONLY  IN  GFCI  PROTECTED 
CIRCUITS. 
 
1) 

Turn off, unplug power, and allow fixture 
to cool before cleaning or servicing.  

 
2) 

Ensure that fixture is properly grounded. 

 
3) 

Ensure  that  heat  sink  fins  are  not 
obstructed. 

 
4) 

Do not look directly at lighted LEDs. 

 
5) 

Keep away from flammable materials.  

 
6) 

No  user  serviceable  parts  inside.  
Replace entire LED assembly. 

 
7) 

Do not touch the LEDs at any time. Use 
a soft lint-free cloth to clean lens. Do not 
use  solvents  to  clean.  Use  cloth 
dampened  with  water.  Allow  to  dry 
completely before reenergizing. 

 
8) 

Do not operate the unit with a missing or 
damaged lens. 

 
 

----------SAVE THESE INSTRUCTIONS!----------- 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

INSTRUCTIONS DE SÛRETÉ 

 
 
LES INSTRUCTIONS AU SUJET D'UN 
RISQUE D'INCENDIE LE CHOC 
ÉLECTRIQUE, OU LA BLESSURE AUX 
PERSONNES POUR SS-PAR-100 
APP AREILS D'É CLAIR AGE DE LED.

 

 

 
AVERTISSEMENT!  -  POUR  RÉDUIRE  LE 
RISQUE  D'INCENDIE,  LE  CHOC  ÉLECTRIQUE, 
OU  LA  BLESSURE  AUX  PERSONNES,  SUIVRE 
CES 

INSTRUCTIONS 

DE 

SÉCURITÉ   

IMPORTANTES

 

ATTENTION : LE RISQUE DE DÉCHARGE 
ÉLECTRIQUE, N'EMPLOIENT PAS LA CORDE 
DE PROLONGATION PRÈS DE L'EAU OU OÙ 
L'EAU PEUT S'ACCUMULER. GARDEZ LA 
LAMPE AU MOINS 16 PIEDS À PARTIR DES 
PISCINES ET DES STATIONS THERMALES. 
MAINTENEZ LES FICHES ET LES DOUILLES 
SÈCHES. POUR L'USAGE SEULEMENT DANS 
DES CIRCUITS PROTÉGÉS PAR GFCI. 
 
 
1)  

Éteignez,  débranchez  la  puissance,  et 
permettez  au  montage  de  se  refroidir 
avant le nettoyage ou l'entretien.  

 
2) 

Assurez-vous  que  le  montage  est 
correctement relié à la terre. 

 

3) 

Assurez-vous que ailerons de radiateur 
ne sont pas obstruées. 

 
4) 

Ne  regardez  pas  directement  la  LED 
allumée. 

 
5) 

S'éloigner des materiaux inflammables. 

 
6) 

Aucunes  pièces  utiles  d'utilisateur  à 
l'intérieur. Remplacez la LED entière. 

 
7) 

Ne touchez pas la LED à tout moment. 

 

Employez  un  chiffon  non  pelucheux 
mou pour nettoyer l'objectif. N'employez 
pas  les  dissolvants  pour  nettoyer.peut 
employer 

le 

tissu 

humecté 

de 

l'eau.laissez sécher complètement avant 
de reenergizing.  

 
8) 

Ne  pas  faire  fonctionner  l'appareil  avec 
un diffuseur antérieur ou une lampe. 

 
 

----------GARDER CES INSTRUCTIONS!----------

 

 

Содержание Spectra-PAR SS-PAR-100

Страница 1: ...a STAR PAR Series Installation and Instruction Manual 2010 Altman Lighting Inc 57 Alexander Street Yonkers New York 10701 U S A Phone 914 476 7987 Fax 914 963 7304 Specifications are subject to change without notice Copyright 2010 Rev 2010 08 30 www altmanlighting com ...

Страница 2: ... RISQUE D INCENDIE LE CHOC ÉLECTRIQUE OU LA BLESSURE AUX PERSONNES POUR SS PAR 100 APPAREILS D É CLAIRAGE DE LED AVERTISSEMENT POUR RÉDUIRE LE RISQUE D INCENDIE LE CHOC ÉLECTRIQUE OU LA BLESSURE AUX PERSONNES SUIVRE CES INSTRUCTIONS DE SÉCURITÉ IMPORTANTES ATTENTION LE RISQUE DE DÉCHARGE ÉLECTRIQUE N EMPLOIENT PAS LA CORDE DE PROLONGATION PRÈS DE L EAU OU OÙ L EAU PEUT S ACCUMULER GARDEZ LA LAMPE ...

Страница 3: ...light engine incorporating Luxeon Rebel LEDs and an on board power supply The LED substrate is coupled to a highly efficient copper heat sink and cooling system for prolonged life of the LEDs The fixture can be ceiling mounted to a pipe or stand mounted All components and electrical devices are ETL or UL Listed or Recognized A safety cable is provided for use when securing the fixture to a pipe PA...

Страница 4: ...r outdoor use it is recommended to mount the fixture with the keypad on the underside to prevent accumulation of dirt water bird droppings etc If track mounted install track adapter into lighting track Connecting power to the fixture Plug the fixture into a grounded receptacle connected to a circuit breaker Connect DMX signal to the fixture Focusing the fixture With the fixture energized point the...

Страница 5: ...rotocols including Wybron Responder System i 8 16 bit DMX 512 control for smoother dimming and color or white fades i Outdoor IP65 rating i Interchangeable front lens and rotating system for different output beam projections i On board power supply microprocessor controller and current drivers i Feed thru DMX RDM data with a maximum total run of 1000 feet i Push button addressing i Stand Alone Pre...

Страница 6: ...from a remote unit will overwrite local DMX setting PERSONALITIES There are 8 different personalities Each personality is made up of 3 settings RESOLUTION 8 Bit 16 Bit MASTER On Off and SMOOTHING On Off which are explained in greater detail below The current active Personality is displayed for about 1 second during power up The format is Pxx where xx is replaced by the active personality 01 08 To ...

Страница 7: ... Channel order is RGBAM 604 Personality 04 8 Bit Master ON Smoothing ON Uses 5 DMX channels Channel order is RGBAM 605 Personality 05 16 Bit Master OFF Smoothing OFF Uses 8 DMX channels Channel order is RrGgBbAa 606 Personality 06 16 Bit Master OFF Smoothing ON Uses 8 DMX channels Channel order is RrGgBbAa 607 Personality 07 16 Bit Master ON Smoothing OFF Uses 10 DMX channels Channel order is RrGg...

Страница 8: ...lectable as ON or OFF and provides a Master fade channel that dims all 4 colors proportionally at the same time in order to maintain the color If you are in 8 Bit mode and the unit is set to DMX Channel 001 then the DMX channels would be CH1 Red CH2 Green CH3 Blue CH4 Amber CH5 Master If you are in 16 Bit mode and the unit is set to DMX Channel 001 then the DMX channels would be CH1 Red Coarse CH2...

Страница 9: ...BE 820 faster 829 slower 830 839 GREEN STROBE 830 faster 839 slower 840 849 BLUE STROBE 840 faster 849 slower 850 858 R A G B RAINBOW STROBE 850 faster 859 slower 870 879 B G A R RAINBOW STROBE 870 faster 879 slower Fixed Color Mode This is a special mode that allows you to manually select colors for a single unit using the 3 keys To enter Fixed Color Mode or exit to Normal Mode Wait a few seconds...

Страница 10: ...c for a moment and then blink Buttons will have no effect until they are unlocked Master and Slave Mode To Turn On or Off the MASTER Wait a few seconds until the display goes blank press and hold the HUNDREDS button press and hold the ONES button release the HUNDREDS button release the ONES button Display will show ON or OFF for a moment and then blink Note to User For White Color LEDs RGBA is rep...