Step 1

. Refer to the ALTINEX website, 

www.altinex.com

, to download the latest 

templates and instructions for tabletop 
cutting requirements and installation. 

In order to do this, locate the 

PNP400

on

the website and go to its detail page. The 
links to the templates, user’s guide, and 
more are on the left-hand side of the 
screen. 

NOTE:

The table can be 0.25-4.0 in 
(6-102 mm) thick. 

Step 2.

Print all information applicable to the 
installation of the 

PNP400

, including the 

templates and any detailed installation 
instructions.

Step 3.

Mark the table’s surface to indicate the 
correct positioning of the unit. The face of 
the unit is typically parallel to the longest 
sides of the tables.

Step 4

. Cut an opening into the table’s surface. 

This operation should be performed by 
experienced professionals in order to 
insure accuracy and to be aesthetically 
pleasing.

NOTE: Always confirm dimensions before 
cutting to insure that specifications have 
not changed. 

Step 5.

Lower the 

PNP400

into the opening in the 

table and make sure the bezel of the unit 
sits evenly in the table.

Step 6

. From under the table, insert the mounting 

brackets into the slots on the side of the 
unit.  See  DIAGRAM  6 on page  10 for 
details.  Place the brackets at the desired 
height  for the table thickness and secure 
them to the bottom of the table using the 
thumb screws provided. There are two 
support brackets, one for each side of the 
unit.

Step 7.

Secure the power cord using  the  cable 
clamp provided. Pass the power cord 
(if any)  from the bottom of the housing 
and attach it to the table leaving a service 
loop beneath the unit.  Before tightening 
the clamp, open and close the unit from 
the top several times. Set the service loop 
for smooth operation only. Do NOT leave 
excessive cable hanging below the table.

Step 8.

Secure other cables from the 

PNP400

to 

the table separate from the power cord. 
All cables should be secured using a 
service loop to allow the unit to open and 
close easily.

Step 9.

Once you have connected power and the 
proper cables to the unit, you may raise 
the unit. To raise the 

PNP400

into 

position, press the top of the unit.

Step 10.

To lower the 

PNP400

, push on the top of 

the unit  until it locks  into place.  Do NOT 
use excessive force to press down on the 
pop-up.

Содержание Pop 'N Plug Tower PNP400

Страница 1: ...DESIGNER SOLUTIONS MANUAL PART NUMBER 400 0109 006 Shown with a silver finish POP N PLUG TOWER USER S GUIDE PNP400...

Страница 2: ...APPLICATION DIAGRAMS 5 DIAGRAM 1 TYPICAL SETUP 5 DIAGRAM 2 CUTOUT 6 DIAGRAM 3 TOP VIEW 7 DIAGRAM 4 FRONT VIEW 8 DIAGRAM 5 SIDE VIEW UP 9 DIAGRAM 6 MOUNTING 10 DIAGRAM 7 INSTALL A SECTIONAL PLATE 11 DI...

Страница 3: ...tlets We recommend using wall outlets with a Ground Fault Circuit Interrupter GFCI for maximum protection 1 3 CLEANING Unplug the PNP400 before cleaning Clean only with a dry cloth Never use strong de...

Страница 4: ...computer video 15 pin HD composite video RCA audio RCA computer audio 3 5 mm stereo phone modem RJ 11 RS 232 9 pin D sub network RJ 45 etc Contact the ALTINEX Sales Department for additional informat...

Страница 5: ...DESIGNER SOLUTIONS 400 0109 006 4 PRODUCT DESCRIPTION 4 CHASSIS BEZEL POP UP LID GAS SPRING MOUNTING HOLES FOR ACCESSORY PLATES front and back TABLETOP THUMB SCREW BRACKET MOUNTING...

Страница 6: ...DESIGNER SOLUTIONS 400 0109 006 5 APPLICATION DIAGRAMS 5 DIAGRAM 1 TYPICAL SETUP...

Страница 7: ...DESIGNER SOLUTIONS 400 0109 006 6 DIAGRAM 2 CUTOUT...

Страница 8: ...DESIGNER SOLUTIONS 400 0109 006 7 DIAGRAM 3 TOP VIEW 7 860 200mm 6 530 166mm...

Страница 9: ...DESIGNER SOLUTIONS 400 0109 006 8 DIAGRAM 4 FRONT VIEW 2 909 74 mm 5 760 146 mm 6 674 170 mm...

Страница 10: ...DESIGNER SOLUTIONS 400 0109 006 9 DIAGRAM 5 SIDE VIEW 2 909 74 mm 5 760 146 mm 4 840 123 mm...

Страница 11: ...BRACKETS MOUNTING BRACKETS DETAILS Install the mounting brackets into the grooves on both sides of the unit using the grooves that best fit the thickness of the tabletop Thread the thumb screws throu...

Страница 12: ...pplied with the sectional plate to fasten the sectional plate to the chassis A rivet tool is supplied with the PNP400 FEED CABLES THROUGH FRONT THROUGH CHASSIS AND DOWN HOLES ALIGN MOUNTING FASTEN WIT...

Страница 13: ...ng SP2301CE AC Power Outlet for Continental Europe SP2401AU AC Power Outlet for Australia New Zealand SP3102EP Dual Empty Snap in Ports with 1 slot SP3103EP Dual Empty Ortronics CAT 6 Snap in Ports wi...

Страница 14: ...the table and make sure the bezel of the unit sits evenly in the table Step 6 From under the table insert the mounting brackets into the slots on the side of the unit See DIAGRAM 6 on page 10 for deta...

Страница 15: ...suggestions for the following Please make sure that the highest quality video audio network and telephone cables or connectors are used If there has been damage then do not use the PNP400 unit Immedia...

Отзывы: