background image

PNP400

PNP400

PNP400

PNP400////Pop ‘N Plug

Pop ‘N Plug

Pop ‘N Plug

Pop ‘N Plug

®

 Tower

 Tower

 Tower

 Tower

    

User’s Guide

    

400-0109-007 

 

 
 
 
 
 
 

Welcome! 

We greatly appreciate your purchase of the PNP400 Pop ‘N Plug Tower. We 
are sure you will find it reliable and simple to use. Superior performance for 
the right price, backed by solid technical and customer support is what 
ALTINEX has to offer. 

We are committed to providing our customers with 
Signal Management Solutions

®

 to the most demanding audiovisual 

installations at competitive pricing and we welcome you to join the ranks of 
our many satisfied customers throughout the world. 

1. Precautions and Safety Warnings 

Please read this manual carefully before using your PNP400 and keep it 
handy for future reference. These safety instructions are to ensure the long 
life of your PNP400 and to prevent fire and shock hazards. Please read them 
carefully and heed all warnings. 

1.1 General 

 

There are no user serviceable parts inside. Qualified ALTINEX service 
personnel must perform all service on the PNP400. 

1.2 Installation Precautions 

 

Place the PNP400 on a flat, leveled surface in a dry area away from dust 
and moisture. 

 

To prevent fire or shock, do not expose this unit to water or moisture. 
Do not place in direct sunlight, near heaters, or heat-radiating 
appliances, or near any liquid. Exposure to direct sunlight, smoke, or 
steam can harm internal components. 

 

Handle the PNP400 carefully; dropping or jarring can cause damage. 

 

Do not pull any cables that are attached to the PNP400. 

 

Do not place heavy objects on top of the PNP400.  

 

Do not use excessive force to push down on the top of the unit. 

 

Do not place fingers inside the PNP400 because of sharp edges inside. 

 

To turn off main power, disconnect AC cords from power outlets. 

 

Use wall outlets with a Ground Fault Circuit Interrupter (GFCI) for 
maximum protection. 

1.3 Cleaning 

 

Unplug the PNP400 before cleaning. 

 

Clean only with a dry cloth. Never use strong detergents or solvents 
such as alcohol or thinner. Do not use a wet cloth or water to clean the 
unit. Do not open the unit to clean. 

1.4 FCC Notice 

 

This device complies with Part 15 of the FCC Rules. Operation is 
subject to the following two conditions: (1) This device may not cause 
harmful interference, and (2) this device must accept any interference 
received, including interference that may cause undesired operation. 

 

This equipment has been tested and found to comply with the limits for 
a Class A digital device, pursuant to Part 15 of the FCC Rules. These 
limits are designed to provide reasonable protection against harmful 
interference when the equipment is operated in a commercial 
environment. This equipment generates, uses, and can radiate radio 
frequency energy and, if not installed and used in accordance with the 
instructions found herein, may cause harmful interference to radio 
communications. Operation of this equipment in a residential area is 
likely to cause harmful interference in which case the user will be 
required to correct the interference at his own expense. 

 

Any changes or modifications to the unit not expressly approved by 
ALTINEX, Inc. could void the user’s authority to operate the 
equipment. 

 

2. Installation Procedures 

Step 1. 

Refer to the ALTINEX website, 

www.altinex.com

, to download the latest templates and instructions for 

tabletop cutting requirements and installation.  In order to do this, locate the PNP400 on the website and go 
to its detail page. The links to the templates, user’s guide, and more are on the left-hand side of the screen.  
The table can be 0.25-4.0 in (6-102 mm) thick. 

Step 2. 

Print all installation information for the PNP400, including the templates and any detailed instructions. 

Step 3. 

Mark the table’s surface to indicate the correct positioning of the unit. The face of the unit is typically 
parallel to the longest sides of the tables. 

Step 4. 

Cut an opening into the table’s surface. This operation should be performed by experienced professionals in order to insure accuracy and to be 
aesthetically pleasing. Always confirm dimensions before cutting to insure that specifications have not changed.  

Step 5. 

Lower the PNP400 into the opening in the table and make sure the bezel of the unit sits evenly in the table. 

Step 6. 

From under the table, insert the mounting brackets into the slots on the side of the unit. See Diagram 6 of the online manual for details. Place the 
brackets (one on each side) at the desired height for the table thickness and secure them to the bottom of the table using the thumb screws provided. 

Step 7. 

Secure the power cord using the cable clamp provided. Pass the power cord (if any) from the bottom of the housing and attach it to the table leaving a 
service loop beneath the unit. Before tightening the clamp, open and close the unit from the top several times. Set the service loop for smooth 
operation only. Do not leave excessive cable hanging below the table. 

Step 8. 

Secure PNP400 signal cables separate from the power cord. All cables should have a service loop to allow the unit to open and close easily. 

Step 9. 

Once you have connected power and the proper cables to the unit, you may raise the unit. To raise the PNP400 into position, press the top of the unit. 

Step 10.  To lower the PNP400, push on the top of the unit until it locks into place.  Do not use excessive force to press down on the pop-up. 

3. Limited Warranty/Return Policies 

Please see the ALTINEX website at 

www.altinex.com

 for details on warranty and return policies. 

 

Содержание PNP400/Pop 'N Plug Tower

Страница 1: ...l environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions found herein may cause harmful interference to radi...

Страница 2: ...information Mechanical PNP400 standard Maximum Table Thickness 4 00 in 102 mm Minimum Table Thickness 0 25 in 6 mm Height Above Table open 2 909 in 74 mm Height Below Table Surface 5 760 in 146 mm Ba...

Страница 3: ...Interconnect has two openings on either side of the unit servicing both sides of a table Several optional sectional plates are available for the following AC power computer video 15 pin HD composite v...

Страница 4: ...PNP400 PNP400 PNP400 PNP400 User s Guide 400 0109 007 4 6 Application Diagrams Diagram 1 Typical Setup...

Страница 5: ...PNP400 PNP400 PNP400 PNP400 User s Guide 400 0109 007 5 Diagram 2 Cutout...

Страница 6: ...PNP400 PNP400 PNP400 PNP400 User s Guide 400 0109 007 6 Diagram 3 Top View 7 860 200mm 6 530 166mm...

Страница 7: ...PNP400 PNP400 PNP400 PNP400 User s Guide 400 0109 007 7 Diagram 4 Front View 2 909 74 mm 5 760 146 mm 6 674 170 mm...

Страница 8: ...PNP400 PNP400 PNP400 PNP400 User s Guide 400 0109 007 8 Diagram 5 Side View 2 909 74 mm 5 760 146 mm 4 840 123 mm...

Страница 9: ...2 MOUNTING BRACKETS MOUNTING BRACKETS DETAILS Install the mounting brackets into the grooves on both sides of the unit using the grooves that best fit the thickness of the tabletop Thread the thumb sc...

Страница 10: ...c rivets supplied with the sectional plate to fasten the sectional plate to the chassis A rivet tool is supplied with the PNP400 FEED CABLES THROUGH FRONT THROUGH CHASSIS AND DOWN HOLES ALIGN MOUNTING...

Страница 11: ...ore Hong Kong SP2301CE AC Power Outlet for Continental Europe SP2401AU AC Power Outlet for Australia New Zealand SP3102EP Dual Empty Snap in Ports with 1 slot SP3103EP Dual Empty Ortronics CAT 6 Snap...

Страница 12: ...ic removable rivets as shown in Diagram 7 8 Troubleshooting Guide We have carefully tested and found no problems in the supplied PNP400 however we would like to offer suggestions for the following Ple...