4. Technical Specifications
Specifications are subject to change. See
Features/Description
MT312-104
General
Connectors
Sensors
5-pin Terminal Block (1)
Relays
5-pin Terminal Block (1)
RS-232
5-pin Terminal Block (1)
IR
5-pin Terminal Block (1)
Accessories Included
Hardware
- Terminal blocks (5)
- Cable ties (8)
Optional Accessories
Ceiling Occupancy Sensor
AC301-101
IR Receiver
AC301-103
Occupancy Sensor
AC301-105
Spare Term. Block Connector
AC101-302
Table 1. MT312-104 General
Mechanical
MT312-104
Slots
1
Weight
0.8 lb. (0.36 kg)
actual 0.7 lb.
Connector Panel
Black Anodized
T° Operating
10°C-45°C
Humidity
90% non-condensing
MTBF (calc.)
38,000 hrs.
Table 2. MT312-104 Mechanical
Electrical
MT312-104
Inputs
Sensor Input
0-24 VDC max.
IR IN
Pass-Through to
IR1+ and IR2+
Outputs
Sensor Power, +12 VDC
+12 VDC, 0.15 A max.
Sensor Power, +24 VDC
+24 VDC, 0.15 A max.
Relays (capacity)
+24 VDC, 0.5 A max.
IR1 & IR2 Modulation
38 kHz or 56 kHz
IR Power, +12 VDC
+12 VDC, 0.15 A max.
Control
RS-232
RX1/TX1
RX2/TX2
Baud Rates 1200 to 57600
Data Bits ..... 8 or 9
8 Bit Parity .. None, Odd, or
Even
Stop Bits ..... 1 or 2
Power
+12V Bus Power
0.2 A (2.4W) max.
Table 3. MT312-104 Electrical
Terminal Block Connections