background image

SWITCHERS

11

11

CB4206MR

6 feet, 5-BNC M to 5-BNC M

CB4212MR

12 feet, 5-BNC M to 5-BNC M

CB4225MR

25 feet, 5-BNC M to 5-BNC M

CB4250MR

50 feet, 5-BNC M to 5-BNC M

CB4275MR

75 feet, 5-BNC M to 5-BNC M

CB42100MR

100 feet, 5-BNC M to 5-BNC M

CB42150MR

150 feet, 5-BNC M to 5-BNC M

SUPER HIGH RESOLUTION 5 BNC TO 5 BNC

COAXIAL CABLE

CB4400MR

Bulk cable (500 feet minimum)

CB4406MR

6 feet, 5-BNC M to 5-BNC M

CB4412MR

12 feet, 5-BNC M to 5-BNC M

CB4425MR

25 feet, 5-BNC M to 5-BNC M

CB4450MR

50 feet, 5-BNC M to 5-BNC M

CB4475MR

75 feet, 5-BNC M to 5-BNC M

CB44100MR

100 feet, 5-BNC M to 5-BNC M

CB44150MR

150 feet, 5-BNC M to 5-BNC M

HIGH RESOLUTION PLENUM-FLEX 5BNC-

5BNC COAXIAL CABLE

CB5000PL-
5BM00035BM

3 feet, 5BNC M to 5-BNC M

CB5000PL-
5BM00065BM

6 feet, 5BNC M to 5-BNC M

CB500PL-
5BM00125BM

12 feet, 5BNC M to 5-BNC M

CB5000PL-
5BM00255BM

25 feet, 5BNC M to 5-BNC M

CB5000PL-
5BM00505BM

50 feet, 5BNC M to 5-BNC M

CB5000PL-
5BM00755BM

75 feet, 5BNC M to 5-BNC M

CB5000PL-
5BM01005BM

100 feet, 5BNC M to 5-BNC M

CB5000PL-
5BM01505BM

150 feet, 5BNC M to 5-BNC M

CB5000PL-
5BM02005BM

200 feet, 5BNC M to 5-BNC M

CB5000PL-
5BM02505BM

250 feet, 5BNC M to 5-BNC M

SUPER HIGH RESOLUTION PLENUM-FLEX 5-

CHANNEL COAX CABLE

CB5100PL –
5BM00035BM

3 feet, 5-BNC M to 5-BNC M

CB5100PL-
5BM00065BM

6 feet, 5-BNC M to 5-BNC M

CB5100PL –

12 feet, 5-BNC M to 5-BNC M

5BM00125BM
CB5100PL –
5BM00255BM

25 feet, 5-BNC M to 5-BNC M

CB5100PL –
5BM00505BM

50 feet, 5-BNC M to 5-BNC M

CB5100PL –
5BM00755BM

75 feet, 5-BNC M to 5-BNC M

CB5100PL –
5BM01005BM

100 feet, 5-BNC M to 5-BNC M

CB5100PL –
5BM01505BM

150 feet, 5-BNC M to 5-BNC M

CB5100PL –
5BM02005BM

200 feet, 5-BNC M to 5-BNC M

CB5100PL –
5BM02505BM

250 feet, 5-BNC M to 5-BNC M

TROUBLE SHOOTING GUIDE

                 10

  Please make sure, that the input signal

formats are the same for the input (source)
and output (display).

  Please make sure that the input signal

amplitude levels are as follows:

1. RED, GREEN, and BLUE are less than 10   
    V.

2. SYNC is less than 5.0 V and more than 0.3

V.

  Please use the appropriate input voltage

110 VAC or 220 VAC.

  Please make sure that proper quality of cables

is used. We recommended ALTINEX made
cables for the best results.

  If a problem arises after continuous usage at

higher voltage, higher temperature, higher
humidity, or at other extreme environmental
conditions, please correct the problem.

  If a problem exists with the switcher, please

reset the unit by pressing the RESET key for
more than 2 seconds

  Make sure that all channels (inputs) are not

OFF (i.e. RED LED is not ON next to the ALL
OFF key).

  If you are using any controllable software or

  hardware to control the 

MX2226AT

,

 

then first

verify operation of the unit using MX Control
software available from the ALTINEX web-site:

Содержание MX2226AT

Страница 1: ...SWITCHERS MANUAL PART NUMBER 400 0030 003 MX2226AT 6 IN 1 OUT RGBHV SWITCHER USER S GUIDE ...

Страница 2: ...CATION 3 MX2226AT DESCRIPTION 4 APPLICATION DIAGRAM 5 INSTALLATION 5 OPERATION 6 OPERATION FROM THE FRONT PANEL 6 RS 232 CONTROL 7 RS 232 CONTROL 8 FEEDBACK CODES 8 MASTER SLAVE CONTROL RS 232 9 LOOP CONTROL 9 FREQUENTLY ASKED QUESTIONS 10 CABLES AND ACCESSORIES 11 TROUBLESHOOTING GUIDE 11 ALTINEX POLICY 12 LIMITED WARRANTY 12 RETURN POLICY 12 CONTACT INFORMATION 12 ...

Страница 3: ...op of the MX2226AT If the MX2226AT is to be mounted to a table or wall use only ALTINEX made DA1292FC 1U High Rack Mount and cables for optimum setup To turn off the main power be sure to remove the cord from the power outlet The power outlet socket should be installed as near to the equipment as possible and should be easily accessible Do not pull the power cord or any cable that is attached to t...

Страница 4: ...s into a no display mode Multiple MX2226AT units may be looped together to create a larger switcher with more than six inputs By connecting two pins on the control port of each switcher used the multiple switchers will act as a single switcher when controlled from the front panel The MX2226AT delivers an extremely high bandwidth of 400 MHz allowing it to remain transparent to even very high resolu...

Страница 5: ... Impedance Pass through Frequency Compatibility Typical Video Bandwidth 400 MHz 3 dB Horizontal 15 200 kHz Vertical 30 190 Hz Horizontal Position Range 20 Cross talk 48 dB 10 MHz Coupling DC Power 90 140V 200 240V Selectable Power Consumption 12 watts max Table 3 MX2226AT Electrical DESCRIPTION OF MODEL NAME 4 ...

Страница 6: ...SWITCHERS 5 5 APPLICATION DIAGRAM 5 ...

Страница 7: ...NPUT This function allows a user to define which input will be selected at power up To define the default power on the input channel while turning ON the unit press the desired channel switch and hold it for approximately 2 seconds until you hear a short beep Turn the unit OFF and then turn it back on again The LED of the selected input should be ON For factory default the input is set to INPUT1 7...

Страница 8: ... H V SYNC or CSYNC of the selected source will continue to be sent to the display This feature can be very helpful when the user does not want the display to go into a no display or no signal mode e g some data monitors will display a blue screen if no signal is present To disable the video portion of the selected input press the video off button once the LED on the top button should light up To e...

Страница 9: ... it would return the feedback as OK INP1 The only exception is that with the VERN command which is the corresponding firmware version of the switcher 1 0 is returned as feedback If a command is not recognized by the switcher an error string ERR will be returned Any command other than the previously listed commands will also return ERR feedback If the control system being used is not set up to paus...

Страница 10: ...d be looped Keep in mind that the Looping Configuration will eliminate one usable input for each looped unit For example if two 6 in 1 out switchers were looped together there would be 11 usable inputs The loop control feature forces all looped units to select input 6 so that the incoming signal will automatically pass through If input from switcher no 1 is selected then input no 6 is automaticall...

Страница 11: ...ter cables for several countries are available through ALTINEX as listed in section 9 7 How do I control several You cannot control multiple MX2226AT Switchers switchers independently with one RS 232 card in a control system independently with one RS 232 control card at this time The unit does not have user selectable ID codes or command delimiters So a command sent by a control card cannot be int...

Страница 12: ...B5100PL 5BM00065BM 6 feet 5 BNC M to 5 BNC M CB5100PL 12 feet 5 BNC M to 5 BNC M 5BM00125BM CB5100PL 5BM00255BM 25 feet 5 BNC M to 5 BNC M CB5100PL 5BM00505BM 50 feet 5 BNC M to 5 BNC M CB5100PL 5BM00755BM 75 feet 5 BNC M to 5 BNC M CB5100PL 5BM01005BM 100 feet 5 BNC M to 5 BNC M CB5100PL 5BM01505BM 150 feet 5 BNC M to 5 BNC M CB5100PL 5BM02005BM 200 feet 5 BNC M to 5 BNC M CB5100PL 5BM02505BM 250...

Страница 13: ...dent 11 2 RETURN POLICY It is very important to ALTINEX that you receive the products that you have ordered and that this product meets your expectations In the unlikely event that an ALTINEX product needs to be returned please follow the policy below ALTINEX will accept product returns for a period of 30 days from authorized ALTINEX dealers Products must be returned in an unopened package If a pr...

Отзывы: