background image

SWITCHERS

2

PRECAUTIONS / SAFETY WARNINGS

1

Please read this manual carefully before using your

MX2216RM

 Switcher. Keep this manual handy for

future reference. These safety instructions are to
ensure the long life of your 

MX2216RM

 and to

prevent fire and shock hazard. Please read them
carefully and heed all warnings.

1.1 GENERAL

 Unauthorized personnel shall not open the unit

since there are high-voltage components
inside.

 Qualified Altinex service personnel, or their

authorized representatives must perform all
service.

1.2 SAFETY GUIDELINES FOR THE RACK-
MOUNTING OF THE MX2216RM

 Maximum operating ambient temperature is 35

(degrees C).

 Never restrict the air flow through the devices’

fan or vents.

 When installing equipment into a rack,

distribute the units evenly. Otherwise,
hazardous conditions may be created by an
uneven weight distribution.

 Connect the unit to a properly rated supply

circuit.

 Reliable Earthing (Grounding) of Rack-Mounted

Equipment should be maintained.

1.3 INSTALLATION

 For best results, place the 

MX2216RM

Switcher on a flat, level surface in a dry area
away from dust and moisture.

 To prevent fire or shock, do not expose this unit

to rain or moisture. Do not place the

MX2216RM

 Switcher in direct sunlight, near

heaters or heat radiating appliances, or near
any liquid. Exposure to direct sunlight, smoke,
or steam can harm internal components.

 Handle the 

MX2216RM

 Switcher carefully.

Dropping or jarring can damage internal
components.

 Do not place heavy objects on top of the

MX2216RM

. If the 

MX2216RM

 is mounted to a

table or wall, use only Altinex made mounting
accessories such as rack mount shelf

DA1298RM

 or rack mount ears 

DA1299RM

and cables for optimum setup.

 To turn off the main power, be sure to remove

the cord from the power outlet. The power
outlet socket should be installed as near to the
equipment as possible, and should be easily
accessible.

 Do not pull the power cord or any cable that is

attached to the 

MX2216RM

 Switcher.

 If the 

MX2216RM

 Switcher is not used for an

extended period, disconnect the power cord
from the power outlet.

1.4 CLEANING

 Unplug the 

MX2216RM

’s power cord before

cleaning. Clean surfaces with a dry cloth. Never
use strong detergents or solvents such as
alcohol or thinner. Do not use a wet cloth or
water to clean the unit.

1.5 FCC / CE NOTICE

 This device complies with part 15 of the FCC

Rules. Operation is subject to the following two
conditions: (1) This device may not cause
harmful interference, and (2) this device must
accept any interference received, including
interference that may cause undesired
operation.

 This equipment has been tested and found to

comply with the limits for a Class A digital
device, pursuant to Part 15 of the FCC Rules.
These limits are designed to provide
reasonable protection against harmful
interference when the equipment is operated in
a commercial environment. This equipment
generates, uses, and can radiate radio
frequency energy and, if not installed and used
in accordance with the instruction manual, may

Содержание MX2216RM

Страница 1: ...SWITCHERS MANUAL PART NUMBER 400 0064 002 PRODUCT REVISION 2 MX2216RM 6 IN 1 OUT RGBS SWITCHER USER S GUIDE...

Страница 2: ...e ranks of our many satisfied customers throughout the world This manual covers MX2216RM 6 in 1 out RGBS Switcher TABLE OF CONTENTS Page PRECAUTIONS SAFETY WARNINGS 2 GENERAL 2 RACK MOUNT SAFETY GUIDE...

Страница 3: ...ly Dropping or jarring can damage internal components Do not place heavy objects on top of the MX2216RM If the MX2216RM is mounted to a table or wall use only Altinex made mounting accessories such as...

Страница 4: ...ion for RS 232 and Contact Closure control as well as other special features For instance when multiple MX2216RM units are looped together to create a larger switcher two pins on the 9 pin control por...

Страница 5: ...nce pass through Frequency Compatibility Horizontal 15 200 kHz Vertical 30 190 Hz Typical Video Bandwidth 400 MHz Cross talk 48dB 10 MHz Coupling DC Power External Power Adapter 90 140V 200 240V selec...

Страница 6: ...he power up sequence 4 6 POWER UP DEFAULT SET This function allows a user to select the channel that will be ON at power up To select the default channel press the selected channel switch and hold it...

Страница 7: ...rd to the unit and plug it into the power outlet Step 3 Connect the cables from the video sources computers to the input channels and connect the output channel to the display device i e monitor or pr...

Страница 8: ...PIN No 3 2 2 3 7 5 Connection of IBM PC 25 pin D to MX2216RM 9 pin D Note 5 6 20 shorted together in IBM side only IBM PIN No MX2216RM PIN No 2 2 3 3 5 5 Connection of IBM PC 9 pin D to MX2216RM 9 pi...

Страница 9: ...cher to respond to any specific output only The default setting is output 1 SETxnnmm x select input number nn Minimum input number mm Maximum input number This command is designed to allow the MX2216R...

Страница 10: ...tact closures The RC5204CC adapter is available to accommodate this need The pin outs for this adapter are as follows 9 pin D Male Description 9 pin D Female Input 7 1 2K 1 1 7 3 3K 2 2 7 6 8K 3 3 7 1...

Страница 11: ...connected to form a single switcher and RS 232 commands are used to control these units please connect the units according to following diagram If you want to create an 11 by 1 switcher using two 6 by...

Страница 12: ...e for US PC5302US Power cable for U K PC5303US Power cable for Australia PC5304US Power cable for Germany FREQUENTLY ASKED QUESTIONS 9 No Question Answer 1 When I press F1 nothing happens What is a pu...

Страница 13: ...d output display Please make sure that the input signal amplitude levels are as follows RED GREEN and BLUE are less than 10 V SYNC is less than 1 0 V and more than 0 3 V Please use the appropriate inp...

Страница 14: ...e products that you have ordered and that this product fulfills your need In the unlikely event that an Altinex product needs to be returned please follow the policies below Altinex will accept produc...

Отзывы: