background image

DISTRIBUTION AMPLIFIERS

6

INSTALLING YOUR DISTRIBUTION
AMPLIFIER

6

Step 1.

Make sure that the proper power supply
is being used with the 

DA1203RM

.

Note: The use of an incorrect power
supply can result in equipment damage
not covered by warranty.

Step 2.

Connect the power cord to the

DA1203RM

 and plug it into the power

outlet. The power indicator LED on the
front panel will light. This indicates that
the unit is operational.

Step 3.

Connect the high resoluti on RGsB or
RGBS source to the 

DA1203RM

 using

coaxial cable with BNC connectors,
making sure that the colors match
correctly. Then connect one or two
monitors or projectors to the output(s) of
the 

DA1203RM

. The monitors or

projectors must be scan-rate compatible
with the source signal - the 

DA1203RM

does not affect scan rate.

Step 5.

If the image is less than perfect, check
all the connections. Also check the
settings of the switches. The default
settings are Sync Polarity (+), Sync
Level (4V), Video Level (0.7V). Check
all the connections. The unit is very
reliable and seldom will this be the
cause of malfunction. Poor quality
cables may often degrade the
performance of the product. Make sure
that the cables used are coaxial cables
and that all pins are in good condition.

CONGRATULATIONS! YOU ARE DONE.

OPERATION

7

The settings of the 

DA1203RM

 Distribution

Amplifier can be adjusted using Input Termination,
Video Level and Sync Level switches as described
in Section no. 4. There are no other adjustments
necessary to operate the unit. The 

DA1203RM

 will

operate successfully as long as cables are
attached properly and other technical specifications
are followed.

ACCESSORIES

8

Model No.

Description

TABLE MOUNT BRACKET

TM1276

Table Mount Bracket for 2U High, ½
rack units

RACK MOUNTING BRACKETS

DA1298RM

Rack Mount shelf for two units

DA1299RM

Rack Mount shelf for single unit

POWER CABLES

PC5301US

9V 500mA Power Supply for US

PC5302UK

9V 500mA Power Supply for UK

PC5303AU

9V 500mA Power Supply for Australia

PC5304GR

9V 500mA Power Supply for Germany

HIGH RESOLUTION 4 BNC to 4 BNC
COAXIAL CABLE

CB4100MR

Bulk Cable 4 coaxes (500ft minimum)

CB4103MR

3 feet, 4 BNC to 4 BNC coaxial cable

CB4106MR

6 feet, 4 BNC to 4 BNC coaxial cable

CB4112MR

12 feet, 4 BNC to 4 BNC coaxial cable

CB4125MR

25 feet, 4 BNC to 4 BNC coaxial cable

CB4150MR

50 feet, 4 BNC to 4 BNC coaxial cable

CB4175MR

75 feet, 4 BNC to 4 BNC coaxial cable

CB41100MR

100 feet, 4 BNC to 4 BNC coaxial cable

CB41150MR

150 feet, 4 BNC to 4 BNC coaxial cable

SUPER HIGH RESOLUTION 4 BNC to
4 BNC COAX

CB4300MR

Bulk Cable 4 coaxes (500ft minimum)

CB4306MR

6 feet, 4 BNC to 4 BNC coaxial cable

CB4312MR

12 feet, 4 BNC to 4 BNC coaxial cable

CB4325MR

25 feet, 4 BNC to 4 BNC coaxial cable

CB4350MR

50 feet, 4 BNC to 4 BNC coaxial cable

CB4375MR

75 feet, 4 BNC to 4 BNC coaxial cable

CB43100MR

100 feet, 4 BNC to 4 BNC coaxial cable

CB43150MR

150 feet, 4 BNC to 4 BNC coaxial cable

If you experience any problems, please call

1-800-258-4623 or 1-714-990-2300 for

international calls.

Содержание DA1203RM

Страница 1: ...DISTRIBUTION AMPLIFIERS MANUAL PART NUMBER 400 0003 003 PRODUCT REVISION 1 DA1203RM 1 IN 3 OUT RGBS DISTRIBUTION AMPLIFIER USER S GUIDE...

Страница 2: ...g audio visual installations at very competitive pricing We appreciate your selection of our products and are confident that you will join the ranks of our many satisfied customers throughout the worl...

Страница 3: ...the DA1203RM If the DA1203RM is to be mounted to a table or wall use only Altinex made mounting accessories Rack Mount Shelf DA1298FC Rack Mount Ears DA1299RM and cables for optimum setup To turn off...

Страница 4: ...ious displays The DA1203RM Distribution Amplifier is a state of the art product with a video bandwidth of 350 MHz enabling it to remain transparent to the video signal passing through it Each output i...

Страница 5: ...idth 350MHz 3dB Typical Video Bandwidth 380MHz 3dB Cable Equalization 3dB 120MHz Coupling DC Cross talk 40dB 10MHz Power Internal Power Supply 90 140V 200 240V Power Consumption 10 watts max Table 3 D...

Страница 6: ...ync level is used This should be considered as default setting The 2V setting allows compatibility with some older equipment that would be overdriven if a stronger signal were used APPLICATION DIAGRAM...

Страница 7: ...hes as described in Section no 4 There are no other adjustments necessary to operate the unit The DA1203RM will operate successfully as long as cables are attached properly and other technical specifi...

Страница 8: ...ons 2V and 4V Most often a 4V Sync Level is used This should be considered as default setting The 2V setting allows compatibility with some older equipment that would be overdriven if a stronger signa...

Страница 9: ...e the product that you have ordered and that this product fulfills your need In the unlikely event that an Altinex product needs to be returned please follow the policies below Altinex will accept pro...

Отзывы: