background image

DISTRIBUTION AMPLIFIERS

2

PRECAUTIONS / SAFETY WARNINGS

1

Please read this manual carefully before using your

DA1203RM

 Distribution Amplifier. Keep this

manual handy for future reference. These safety
instructions are to ensure the long life of your

DA1203RM 

and to prevent fire and shock hazard.

Please read them carefully and heed all warnings.

1.1 GENERAL

 Unauthorized personnel shall not open the unit

since there are high-voltage components inside.

 Qualified Altinex service personnel, or their

authorized representatives must perform all
service.

1.2 SAFETY GUIDELINES FOR THE RACK-

MOUNTING OF THE DA1203RM

 Maximum operating ambient temperature is 35

(degrees C).

 Never restrict the air flow through the devices’

fan or vents.

 When installing equipment into a rack,

distribute the units evenly. Otherwise,
hazardous conditions may be created by an
uneven weight distribution.

 Connect the unit to a properly rated supply

circuit.

 Reliable Earthing (Grounding) of Rack-

Mounted Equipment should be maintained.

1.3 INSTALLATION

 For best results, place the 

DA1203RM

Distribution Amplifier on a flat, level surface in a
dry area away from dust and moisture.

 To prevent fire or shock, do not expose this unit

to rain or moisture. Do not place the 

DA1203RM

Distribution Amplifier in direct sunlight, near
heaters or heat radiating appliances, or near any
liquid. Exposure to direct sunlight, smoke, or
steam can harm internal components.

 Handle the 

DA1203RM

 Distribution Amplifier

carefully. Dropping or jarring can damage
internal components.

 Do not place heavy objects on top of the

DA1203RM

. If the 

DA1203RM

 is to be mounted,

to a table or wall, use only Altinex made
mounting accessories (Rack Mount Shelf

DA1298FC,

 Rack Mount Ears 

DA1299RM

) and

cables for optimum setup.

 To turn off main power, be sure to remove the

cord from power outlet. The power outlet socket
should be installed as near to the equipment as
possible, and should be easily accessible.

 Do not pull power cord or any cable that is

attached to the 

DA1203RM

 Distribution

Amplifier.

 If the 

DA1203RM

 Distribution Amplifier is not to

be used for an extended period of time,
disconnect the power cord from the power
outlet.

1.4 CLEANING

 Unplug the 

DA1203RM

 power cord before

cleaning. Clean surfaces with a dry cloth. Never
use strong detergents or solvents such as
alcohol or thinner. Do not use a wet cloth or
water to clean the unit.

1.5 FCC / CE NOTICE

 This device complies with part 15 of the FCC

Rules. Operation is subject to the following two
conditions: (1) This device may not cause
harmful interference, and (2) this device must
accept any interference received, including
interference that may cause undesired
operation.

 This equipment has been tested and found to

comply with the limits for a Class A digital
device, pursuant to Part 15 of the FCC Rules.
These limits are designed to provide reasonable
protection against harmful interference when the
equipment is operated in a commercial
environment. This equipment generates, uses,
and can radiate radio frequency energy and, if
not installed and used in accordance with the
instruction manual, may cause harmful
interference to radio communications. Operation
of this equipment in a residential area is likely to
cause harmful interference in which case the
user will be required to correct the interference
at his own expense.

Содержание DA1203RM

Страница 1: ...DISTRIBUTION AMPLIFIERS MANUAL PART NUMBER 400 0003 003 PRODUCT REVISION 1 DA1203RM 1 IN 3 OUT RGBS DISTRIBUTION AMPLIFIER USER S GUIDE...

Страница 2: ...g audio visual installations at very competitive pricing We appreciate your selection of our products and are confident that you will join the ranks of our many satisfied customers throughout the worl...

Страница 3: ...the DA1203RM If the DA1203RM is to be mounted to a table or wall use only Altinex made mounting accessories Rack Mount Shelf DA1298FC Rack Mount Ears DA1299RM and cables for optimum setup To turn off...

Страница 4: ...ious displays The DA1203RM Distribution Amplifier is a state of the art product with a video bandwidth of 350 MHz enabling it to remain transparent to the video signal passing through it Each output i...

Страница 5: ...idth 350MHz 3dB Typical Video Bandwidth 380MHz 3dB Cable Equalization 3dB 120MHz Coupling DC Cross talk 40dB 10MHz Power Internal Power Supply 90 140V 200 240V Power Consumption 10 watts max Table 3 D...

Страница 6: ...ync level is used This should be considered as default setting The 2V setting allows compatibility with some older equipment that would be overdriven if a stronger signal were used APPLICATION DIAGRAM...

Страница 7: ...hes as described in Section no 4 There are no other adjustments necessary to operate the unit The DA1203RM will operate successfully as long as cables are attached properly and other technical specifi...

Страница 8: ...ons 2V and 4V Most often a 4V Sync Level is used This should be considered as default setting The 2V setting allows compatibility with some older equipment that would be overdriven if a stronger signa...

Страница 9: ...e the product that you have ordered and that this product fulfills your need In the unlikely event that an Altinex product needs to be returned please follow the policies below Altinex will accept pro...