EKHBH/XE008AA3V3

Indoor unit for air to water heat pump system and options

4PW48442-1B

Operation manual

6

Selecting quiet mode operation (

s

)

1

Use the 

s

 button to activate quiet mode operation (

s

).

Icon 

s

 appears on the display.

If the controller is set in permission level 2 or 3 (refer to 

"Field

settings" on page 11

), the 

s

 button will not be operable.

Selecting weather dependent set point operation (only in
heating mode)

1

Press the 

ba

  button to select weather dependent set point

operation.

Icon 

a

  appears on the display as well as the shift value. The

shift value is not shown in case it is 0.

2

Use the 

bi

 and 

bj

 buttons to set the shift value.

Range for the shift value: –5°C to +5°C

Displaying actual temperatures

1

Push the 

ba

 button for 5 seconds.

The 

b

 icon and the outgoing water temperature are displayed.

The icons 

l

 and 

=

 are flashing.

2

Use the 

pi

 and 

pj

 buttons to display:

The outdoor temperature (

u

 icon is flashing).

The domestic hot water tank temperature (

w

  icon is

flashing).

The outgoing water temperature (

=

 are flashing).

If no button is pressed for 5 seconds, the controller leaves the
display mode.

Schedule timer operation

In schedule timer operation, the installation is controlled by the
schedule timer. The actions programmed in the schedule timer will be
executed automatically.

The schedule timer always follows the last command until a new
command is given. This means that the user can temporarily overrule
the last executed programmed command by manual operation (Refer
to 

"Manual operation" on page 5

). The schedule timer will regain

control over the installation as soon as the next programmed
command of the schedule timer occurs.

The schedule timer is enabled (

p

 icon displayed) or disabled (

p

 icon

not displayed), by pressing the 

pr

 button.

To set up the SCHEDULE TIMER refer to chapter 

"Programming and

consulting the schedule timer" on page 7

.

What can the schedule timer do?

The schedule timer allows the programming of:

1.

Space heating and space cooling (refer to 

"Programming space

cooling or space heating" on page 8

)

Switch on the desired mode at a scheduled time, in combination
with a set point (weather dependent or manually set). Five
actions per weekday can be programmed, totalling 35 actions.

2.

Quiet mode (refer to 

"Programming quiet mode, booster heating

or domestic water heating" on page 9

)

Switch the mode on or off at a scheduled time. Five actions can
be programmed per mode. These actions are repeated daily.

3.

Booster heating (refer to 

"Programming quiet mode, booster

heating or domestic water heating" on page 9

)

Allow or disallow booster heating at a scheduled time. Five
actions can be programmed per mode. These actions are
repeated daily.

4.

Domestic water heating (refer to 

"Programming quiet mode,

booster heating or domestic water heating" on page 9

)

Switch the mode on or off at a scheduled time. Five actions can
be programmed per mode. These actions are repeated daily.

NOTE

Remark that pushing the 

y

 button has no influence

on the domestic water heating. Domestic water
heating is only switched on or off by means of the 

v

button.

NOTE

Only use the 

pr

 button to enable or disable the

schedule timer. The schedule timer overrules the

y

  button. The 

y

  button only overrules the

schedule timer until the next programmed action.

If the auto restart function is disabled, the
schedule timer will not be activated when power
returns to the unit after a power supply failure.
Press the 

pr

 button to enable the schedule timer

again.

When power returns after a power supply failure,
the auto restart function reapplies the user
interface settings at the time of the power supply
failure.

It is therefore recommended to leave the auto
restart function enabled.

The programmed schedule is time driven. Therefore, it
is essential to set the clock and the day of the week
correctly. Refer to 

"Setting the clock" on page 4

.

Manually adjust the clock for summertime and
wintertime. Refer to 

"Setting the clock" on page 4

.

A power failure exceeding 1 hour will reset the clock
and the day of the week. The schedule timer will
continue operation, but with a disordered clock. Refer
to 

"Setting the clock" on page 4

  to adjust the clock

and the day of the week.

The actions programmed in the schedule timer will not
be lost after a power failure so that reprogramming the
schedule timer is not required.

NOTE

When the unit is connected to an external room
thermostat, the schedule timer for space cooling and
space heating is overruled by the external room
thermostat.

The programmed actions are not stored according to
their timing but according to the time of programming.
This means that the action that was programmed first
gets action number 1, even though it is executed after
other programmed action numbers.

When the schedule timer switches space heating or
space cooling 

x

, the controller will also be

switched off. Note that this has no influence on
domestic water heating.

Содержание EKHBHE008AA3V3

Страница 1: ...OPERATION MANUAL EKHBHE008AA3V3 EKHBXE008AA3V3 Indoor unit for air to water heat pump system and options For installation WITH restricted power supply condition 6 kW ...

Страница 2: ...an coil units floor heating low temperature radiators the Daikin domestic hot water tanks and the solar option kit The AD indoor unit range consists of two main versions a heating cooling EKHBX version and a heating only EKHBH version Both versions are delivered with an integrated backup heater The backup heater only serves as a backup in case of malfunctioning of the outdoor unit or when the unit...

Страница 3: ...l start up for example Refer to Initial start up at low outdoor ambient temperatures and Re start at low outdoor ambient temperatures in the installation manual During heating operation the water temperature becomes too low and drops ot of the operation range Refer to Checking the water volume and expansion vessel pre pressure in the installation manual to minimize the backup heater operation Malf...

Страница 4: ...on will never be displayed If the solar option is installed and active the w icon will be blinking 4 EXTERNAL CONTROL ICON e This icon indicates that an external room thermostat with higher priority is controlling your installation This external room thermostat can start and stop the space heating cooling operation and change the operation mode cooling heating When an external room thermostat with...

Страница 5: ...able the schedule timer The button is also used to program the controller The function of the button depends on the actual status of the controller or on previous actions carried out by the operator If the controller is set in permission level 3 refer to Field settings on page 11 the schedule timer button will not be operable 31 TIME ADJUST BUTTON pi and pj These multi purpose buttons are used to ...

Страница 6: ...ating should only be set lower than 25 C during commissioning of the installation When set lower than 25 C only the backup heater will operate In order to avoid overheating space heating is not operable when the outdoor ambient temperature rises above a certain temperature as set through field setting 4 02 refer to Field settings on page 11 Temperature range for cooling 5 C to 22 C 3 Switch on the...

Страница 7: ...t a scheduled time Five actions can be programmed per mode These actions are repeated daily 3 Booster heating refer to Programming quiet mode booster heating or domestic water heating on page 9 Allow or disallow booster heating at a scheduled time Five actions can be programmed per mode These actions are repeated daily 4 Domestic water heating refer to Programming quiet mode booster heating or dom...

Страница 8: ...er If 2 or more actions are programmed for the same day and at the same time only the action with the highest action number will be executed You can always alter add or remove the programmed actions later When programming heating actions time and set point cooling actions are added automatically at the same time but with the predefined default cooling set point Conversely when programming cooling ...

Страница 9: ... to select x to switch cooling or heating and the controller off 9 set the temperature by means of the bi and bj buttons a to select automatic temperature calculation only in heating mode 10 Use the pi and pj buttons to set the correct action time 11 Repeat steps 8 to 10 to program the other actions of the selected day When all actions have been programmed make sure that the display shows the high...

Страница 10: ...ulting space cooling or space heating is carried out as follows 1 Use the button to select the operation mode cooling or heating you want to consult 2 Press the button The actual mode is blinking 3 Press the button to confirm the selected mode The actual day is blinking 4 Select the day you would like to consult by means of the pi and pj buttons The selected day is blinking 5 Press the button to c...

Страница 11: ...y will show the next day e g 2 if 1 was selected first This indicates that the day has been copied You can return to step 2 by pressing the pr button Deleting one or more programmed actions Deleting one or more programmed actions is done at the same time as storing the programmed actions When all actions for one day have been programmed make sure that the display shows the highest action number yo...

Страница 12: ...seconds in normal mode Note that no indication on the user interface is given When level 2 3 is selected the actual permission level either level 2 or level 3 is determined by the field setting 0 00 1 Weather dependent set point heating operation only The weather dependent set point field settings define the parameters for the weather dependent operation of the unit When weather dependent operatio...

Страница 13: ...erature Shift value The disinfection function field settings must be configured by the installer according to national and local regulations TDHW Domestic hot water temperature TU User set point temperature as set on the user interface TH High set point temperature 2 03 t Time Space cooling heating always has priority over the disinfection function The disinfection function is only possible when t...

Страница 14: ...revents the booster heater from repeatedly turning on and off i e chattering to maintain the domestic hot water set point temperature Note the booster heater will turn back on when the domestic hot water temperature drops 2 C fixed value below the booster heater OFF temperature 7 00 Domestic hot water step length temperature difference above the domestic hot water set point temperature before the ...

Страница 15: ...aving water temperature for cooling operation 9 03 Cooling set point lower limit minimum leaving water temperature for cooling operation 9 04 Overshoot setting defines how much the water temperature may rise above the setpoint before the compressor stops This function is only applicable in heating mode C Solar priority mode C 00 For information concerning the EKSOLHW solar kit refer to the install...

Страница 16: ...rity temperature 00 Not applicable Do not change the default value 1 01 Not applicable Do not change the default value 0 02 Not applicable Do not change the default value 0 03 Not applicable Do not change the default value 0 04 Not applicable Do not change the default value 10 6 DT for domestic water heating 00 Start 5 1 20 1 C 01 Stop 2 2 10 1 C 7 Domestic hot water step length 00 Domestic hot wa...

Страница 17: ... readout 00 Software version Read only 01 EEPROM version Read only 02 Unit model identification Read only 03 Liquid refrigerant temperature Read only C 04 Inlet water temperature Read only C First code Second code Setting name Installer setting at variance with default value Default value Range Step Unit Date Value Date Value ...

Страница 18: ...eck if the clock and the day of the week are set correctly correct if necessary DISPOSAL REQUIREMENTS Dismantling of the unit treatment of the refrigerant of oil and of other parts must be done in accordance with relevant local and national legislation Do not try to dismantle the system yourself the dismantling of the system treatment of the refrigerant of oil and other parts must be done by a qua...

Страница 19: ......