What can the schedule timer NOT do?

The schedule timer can not change the operation mode from space
cooling to space heating or vice versa.

How to interpret the programmed actions

To be able to understand the behaviour of your installation when the
schedule timer is enabled, it is important to keep in mind that the
"last" programmed command overruled the "preceding" programmed
command and will remain active until the "next" programmed
command occurs.

Example: imagine the actual time is 17:30 and actions are
programmed at 13:00, 16:00 and 19:00. The "last" programmed
command (16:00) overruled the "previous" programmed command
(13:00) and will remain active until the "next" programmed command
(19:00) occurs.

So in order to know the actual setting, one should consult the last
programmed command. It is clear that the "last" programmed
command may date from the day before. Refer to 

"Consulting

programmed actions" on page 9

.

Programming and consulting the schedule timer

Getting started

Programming the schedule timer is flexible (you can add, remove or
alter programmed actions whenever required) and straightforward
(programming steps are limited to a minimum). However, before
programming the schedule timer, remind:

Familiarise yourself with the icons and the buttons. You will need
them when programming. Refer to 

"Name and function of

buttons and icons" on page 3

.

Fill out the form at the very end of this manual. This form can
help you define the required actions for each day. Keep in mind
that:
-

In the space cooling/heating program, 5 actions can be 
programmed per weekday. The same actions are repeated 
on a weekly basis.

-

In the domestic water heating, booster heater and quiet 
mode program, 5 actions can be programmed per mode. The 
same actions are repeated on a daily basis.

Take your time to enter all data accurately.

Try to program the actions in a chronological way: start with
action 1 for the first action and end with the highest number for
the last action. This is not a requirement but will simplify the
interpretation of the program later.

If 2 or more actions are programmed for the same day and at the
same time, only the action with the highest action number will be
executed.

You can always alter, add or remove the programmed actions
later.

When programming heating actions (time and set point), cooling
actions are added automatically at the same time but with the
predefined default cooling set point. Conversely, when
programming cooling actions (time and setpoint), heating
actions are added automatically at the same time but with the
default heating set point.

The set points of these automatically added actions can be
adjusted by programming the corresponding mode. This means
that after programming heating, you should also program the
corresponding cooling set points and vice versa.

NOTE

During schedule timer operation, someone may have
altered the actual settings manually (in other words,
the "last" command was overruled manually). The icon

p

, indicating the schedule timer operation, may still be

displayed, giving the impression that the "last"
command settings are still active. The "next"
programmed command will overrule the altered
settings and return to the original program.

Due to the fact that the schedule timer cannot switch
between operation modes (cooling or heating) and the fact
that each programmed action implies a cooling setpoint
and a heating setpoint, the following situations may occur:

when the schedule timer is active in heating mode,
and the mode is changed manually to cooling (by
means of the 

=

  button), the operation mode will

from then on remain cooling and program actions will
follow the corresponding cooling setpoints. Returning
to heating mode needs to be carried out manually (by
means of the 

=

 button).

when the schedule timer is active in cooling mode,
and the mode is changed manually to heating (by
means of the 

=

  button), the operation mode will

from then on remain heating and program actions will
follow the corresponding heating setpoints. Returning
to cooling mode needs to be carried out manually (by
means of the 

=

 button).

The above proves the importance of programming both
cooling and heating setpoints for each action. If you do not
program these setpoints, the predefined default values will
be used.

Before you start any programming, read attentively the
warnings mentioned in the paragraph 

"Introduction" on

page 2

 to understand unit operation.

Содержание EKHBHE008AA3V3

Страница 1: ...OPERATION MANUAL EKHBHE008AA3V3 EKHBXE008AA3V3 Indoor unit for air to water heat pump system and options For installation WITH restricted power supply condition 6 kW ...

Страница 2: ...an coil units floor heating low temperature radiators the Daikin domestic hot water tanks and the solar option kit The AD indoor unit range consists of two main versions a heating cooling EKHBX version and a heating only EKHBH version Both versions are delivered with an integrated backup heater The backup heater only serves as a backup in case of malfunctioning of the outdoor unit or when the unit...

Страница 3: ...l start up for example Refer to Initial start up at low outdoor ambient temperatures and Re start at low outdoor ambient temperatures in the installation manual During heating operation the water temperature becomes too low and drops ot of the operation range Refer to Checking the water volume and expansion vessel pre pressure in the installation manual to minimize the backup heater operation Malf...

Страница 4: ...on will never be displayed If the solar option is installed and active the w icon will be blinking 4 EXTERNAL CONTROL ICON e This icon indicates that an external room thermostat with higher priority is controlling your installation This external room thermostat can start and stop the space heating cooling operation and change the operation mode cooling heating When an external room thermostat with...

Страница 5: ...able the schedule timer The button is also used to program the controller The function of the button depends on the actual status of the controller or on previous actions carried out by the operator If the controller is set in permission level 3 refer to Field settings on page 11 the schedule timer button will not be operable 31 TIME ADJUST BUTTON pi and pj These multi purpose buttons are used to ...

Страница 6: ...ating should only be set lower than 25 C during commissioning of the installation When set lower than 25 C only the backup heater will operate In order to avoid overheating space heating is not operable when the outdoor ambient temperature rises above a certain temperature as set through field setting 4 02 refer to Field settings on page 11 Temperature range for cooling 5 C to 22 C 3 Switch on the...

Страница 7: ...t a scheduled time Five actions can be programmed per mode These actions are repeated daily 3 Booster heating refer to Programming quiet mode booster heating or domestic water heating on page 9 Allow or disallow booster heating at a scheduled time Five actions can be programmed per mode These actions are repeated daily 4 Domestic water heating refer to Programming quiet mode booster heating or dom...

Страница 8: ...er If 2 or more actions are programmed for the same day and at the same time only the action with the highest action number will be executed You can always alter add or remove the programmed actions later When programming heating actions time and set point cooling actions are added automatically at the same time but with the predefined default cooling set point Conversely when programming cooling ...

Страница 9: ... to select x to switch cooling or heating and the controller off 9 set the temperature by means of the bi and bj buttons a to select automatic temperature calculation only in heating mode 10 Use the pi and pj buttons to set the correct action time 11 Repeat steps 8 to 10 to program the other actions of the selected day When all actions have been programmed make sure that the display shows the high...

Страница 10: ...ulting space cooling or space heating is carried out as follows 1 Use the button to select the operation mode cooling or heating you want to consult 2 Press the button The actual mode is blinking 3 Press the button to confirm the selected mode The actual day is blinking 4 Select the day you would like to consult by means of the pi and pj buttons The selected day is blinking 5 Press the button to c...

Страница 11: ...y will show the next day e g 2 if 1 was selected first This indicates that the day has been copied You can return to step 2 by pressing the pr button Deleting one or more programmed actions Deleting one or more programmed actions is done at the same time as storing the programmed actions When all actions for one day have been programmed make sure that the display shows the highest action number yo...

Страница 12: ...seconds in normal mode Note that no indication on the user interface is given When level 2 3 is selected the actual permission level either level 2 or level 3 is determined by the field setting 0 00 1 Weather dependent set point heating operation only The weather dependent set point field settings define the parameters for the weather dependent operation of the unit When weather dependent operatio...

Страница 13: ...erature Shift value The disinfection function field settings must be configured by the installer according to national and local regulations TDHW Domestic hot water temperature TU User set point temperature as set on the user interface TH High set point temperature 2 03 t Time Space cooling heating always has priority over the disinfection function The disinfection function is only possible when t...

Страница 14: ...revents the booster heater from repeatedly turning on and off i e chattering to maintain the domestic hot water set point temperature Note the booster heater will turn back on when the domestic hot water temperature drops 2 C fixed value below the booster heater OFF temperature 7 00 Domestic hot water step length temperature difference above the domestic hot water set point temperature before the ...

Страница 15: ...aving water temperature for cooling operation 9 03 Cooling set point lower limit minimum leaving water temperature for cooling operation 9 04 Overshoot setting defines how much the water temperature may rise above the setpoint before the compressor stops This function is only applicable in heating mode C Solar priority mode C 00 For information concerning the EKSOLHW solar kit refer to the install...

Страница 16: ...rity temperature 00 Not applicable Do not change the default value 1 01 Not applicable Do not change the default value 0 02 Not applicable Do not change the default value 0 03 Not applicable Do not change the default value 0 04 Not applicable Do not change the default value 10 6 DT for domestic water heating 00 Start 5 1 20 1 C 01 Stop 2 2 10 1 C 7 Domestic hot water step length 00 Domestic hot wa...

Страница 17: ... readout 00 Software version Read only 01 EEPROM version Read only 02 Unit model identification Read only 03 Liquid refrigerant temperature Read only C 04 Inlet water temperature Read only C First code Second code Setting name Installer setting at variance with default value Default value Range Step Unit Date Value Date Value ...

Страница 18: ...eck if the clock and the day of the week are set correctly correct if necessary DISPOSAL REQUIREMENTS Dismantling of the unit treatment of the refrigerant of oil and of other parts must be done in accordance with relevant local and national legislation Do not try to dismantle the system yourself the dismantling of the system treatment of the refrigerant of oil and other parts must be done by a qua...

Страница 19: ......

Страница 20: ...4PW48442 1B Copyright Daikin ...

Отзывы: