6 Maintenance 

The  flawless  function  and  calibration  of  the whole  measuring  system is  to  be  checked  regularly. This 
inspection  is  also  necessary  after  every  repair  or  change  of  any  component  of  the  measurement 
system. 



7 Old appliances disposal 

 

According to European and German law, it is prohibited to dispose of old electronic 
devices into household waste but must be collected and disposed of separately. 

 

Amplifiers  and  measurement  units  manufactured  and  sold  by  Althen  Mess-  &  Sensortechnik  GmbH 
serve B2B purposes only. Therefore, those old appliances must not be given to the communal disposer, 
but must be given back to the seller or disposed of properly. If you need any further information, please 
contact your local authorities. 

These  measures  serve  to  protect  the  environment  and  allow  recycling  and  recovery  of  valuable 
materials.  Furthermore,  do  electronic  devices  contain  substances  that  may  cause  damage  to  the 
environment if burned or dumped with normal household waste. 

 

 

Содержание NM1-ISU-IP-3L-24 Series

Страница 1: ...l France Althen DB Innovation Tél 0033 0 4 67 78 61 66 info althensensors fr Sweden Althen Sensors Control AB Tel 46 0 8 7 95 24 90 info althensensors de USA Canada Altheris Inc Sensors Controls Inc Tel 1 858 633 3572 info althensensors com Other Countries please contact us by email at sales althensensors com www althen de V2 1 eng Single Axis Tilt Measuring System ...

Страница 2: ...r use of the measuring amplifier 4 3 Technical Description 5 4 Terminal Assignment 5 4 1 Supply Voltage 5 4 2 Measuring value output RS 232 5 4 2 1 Measuring value output 4 20 mA 5 5 Starting up 6 6 Maintenance 8 7 Old appliances disposal 8 Appendix 9 Datasheet 9 Order Designation 9 Component diagram 10 Housing dimensions 11 ...

Страница 3: ...ce The complete measuring unit must be protected against contact and influence of unauthorized persons In case of a safety relevant application where a potential malfunction could cause damage to property or persons it is imperative that an additional independent monitor is provided In combination with sensors the maximum loads pressures etc must never be exceeded If you have reasons to assume tha...

Страница 4: ...be connected to clean earth potential Please refer to the EMC Mounting Instructions in order to connect the sensor shields correctly To avoid possible potential equalization currents over the shield of the cable to the following evaluation unit this shield should be connected over a suitable capacitor 10 nF 200 V Overall the shield connections must be done properly to EMC standards as short as pos...

Страница 5: ...e is connected to the housing Clamp Description Color 1 Supply voltage white 2 GND Supply voltage brown 3 RS232 interface 9600 Baud 8N1 pink 4 External control signal for tare zero grey 5 GND Analogue output green 6 Analogue output 4 20 mA yellow EMC Cable gland Shield Cable shield blank In order to tare the read out put 24V on pin 4 It is to be secured against unintentional operation 4 1 Supply V...

Страница 6: ...01 1 S 01 2 S 01 3 S 01 4 range polarity of analogue output OFF OFF OFF X 10 OFF OFF ON X 20 OFF ON OFF X 30 OFF ON ON X 45 ON OFF OFF X 60 ON OFF ON X 90 ON ON OFF X 120 ON ON ON X 180 X X X ON range range 4 mA 20 mA X X X OFF range range 20 mA 4 mA X not involved Notice In order to prevent moisture from intruding it is recommended that after final setup the dip switch gets sealed with some silic...

Страница 7: ...Fig 1b Button for tare There are 3 internal LED s LED Color Action Description 1 yellow flashes measured values are present and are being outputted 2 red flashes chosen range has been exceeded 2 red lights up for approx 1 sec system is being zeroed tared after putting 24 Volts to clamp 4 pushing the button 3 green on Indicates internal supply voltage Notice In the case of a safety relevant applica...

Страница 8: ...sposed of separately Amplifiers and measurement units manufactured and sold by Althen Mess Sensortechnik GmbH serve B2B purposes only Therefore those old appliances must not be given to the communal disposer but must be given back to the seller or disposed of properly If you need any further information please contact your local authorities These measures serve to protect the environment and allow...

Страница 9: ...type Unitronic FD CP plus 3x2x0 25mm Housing EMC aluminum die cast Protection class IP66 Dimensions W x H x D 150x65x36 mm w o cable gland Weight ca 630 g incl 3 m Cable Electronics not encapsulated ca 1150 g incl 10 m Cable Electronics not encapsulated Storage temperature range 20 C 60 C Operating temperature range 20 C 60 C Order Designation NM1 ISU IP 3L 24 1 axis industrial inclination measure...

Страница 10: ...10 11 Component diagram ...

Страница 11: ...11 11 Housing dimensions Subject to modifications All information describes our products in general form ...

Отзывы: