background image

 

3 | 11

 

 



1 General Information 

To  ensure  reliable  and  safe  operation,  the  measuring  amplifier  must  be  operated  in  compliance  with 
the specifications according to this technical description only. These regulations must also be observed 
if accessories, which have been ordered from Althen Mess- & Sensortechnik GmbH together with the 
measuring amplifier, are being used. 

Notice:

 

Every person who is in charge for the start-up or service of this measuring amplifier must have 

read this technical manual and must have understood the safety instructions in particular. 



1.1 Safety Instructions 

When  using  the  amplifier,  the  legal-  and  safety  regulations  for  each  case  of  application  must  be 
observed. To avoid risks for the system or the operator the following points are to be considered. 

 

 

If any visual damage or malfunctions are noticed, the measuring system must be switched 
off and marked appropriately. 

 

Disconnect the supply voltage before opening the device.  

 

The  complete  measuring  unit  must  be  protected  against  contact  and  influence  of 
unauthorized persons.  

 

In case of a safety-relevant application, where a potential malfunction could cause damage 
to property or persons, it is imperative that an additional, independent monitor is provided. 

 

In combination with sensors, the maximum loads / pressures etc. must never be exceeded. 

 

If you have reasons to assume that a safe operation is no longer possible, immediately take the device 
out of operation and secure it against unintentional operation. 



1.2 Qualified Personnel  

This measuring system must be operated by qualified personnel and in compliance with the relevant 
technical  specifications  only.  Qualified  personnel  include  such  persons  who  are  conversant  with  the 
setting  up,  mounting  and  starting  up  of  the  measuring  system  and  who  have  qualifications  that  are 
appropriate for the tasks they're about to perform. 



1.3 Intended Use 

Amplifiers from Althen Mess- & Sensortechnik GmbH serve to measure the intended measurand and 
the evaluation thereof in combination with one or more sensors. Any other use over and above that is 
regarded as non-intended use. 

 

 

Содержание NM1-ISU-IP-3L-24 Series

Страница 1: ...l France Althen DB Innovation Tél 0033 0 4 67 78 61 66 info althensensors fr Sweden Althen Sensors Control AB Tel 46 0 8 7 95 24 90 info althensensors de USA Canada Altheris Inc Sensors Controls Inc Tel 1 858 633 3572 info althensensors com Other Countries please contact us by email at sales althensensors com www althen de V2 1 eng Single Axis Tilt Measuring System ...

Страница 2: ...r use of the measuring amplifier 4 3 Technical Description 5 4 Terminal Assignment 5 4 1 Supply Voltage 5 4 2 Measuring value output RS 232 5 4 2 1 Measuring value output 4 20 mA 5 5 Starting up 6 6 Maintenance 8 7 Old appliances disposal 8 Appendix 9 Datasheet 9 Order Designation 9 Component diagram 10 Housing dimensions 11 ...

Страница 3: ...ce The complete measuring unit must be protected against contact and influence of unauthorized persons In case of a safety relevant application where a potential malfunction could cause damage to property or persons it is imperative that an additional independent monitor is provided In combination with sensors the maximum loads pressures etc must never be exceeded If you have reasons to assume tha...

Страница 4: ...be connected to clean earth potential Please refer to the EMC Mounting Instructions in order to connect the sensor shields correctly To avoid possible potential equalization currents over the shield of the cable to the following evaluation unit this shield should be connected over a suitable capacitor 10 nF 200 V Overall the shield connections must be done properly to EMC standards as short as pos...

Страница 5: ...e is connected to the housing Clamp Description Color 1 Supply voltage white 2 GND Supply voltage brown 3 RS232 interface 9600 Baud 8N1 pink 4 External control signal for tare zero grey 5 GND Analogue output green 6 Analogue output 4 20 mA yellow EMC Cable gland Shield Cable shield blank In order to tare the read out put 24V on pin 4 It is to be secured against unintentional operation 4 1 Supply V...

Страница 6: ...01 1 S 01 2 S 01 3 S 01 4 range polarity of analogue output OFF OFF OFF X 10 OFF OFF ON X 20 OFF ON OFF X 30 OFF ON ON X 45 ON OFF OFF X 60 ON OFF ON X 90 ON ON OFF X 120 ON ON ON X 180 X X X ON range range 4 mA 20 mA X X X OFF range range 20 mA 4 mA X not involved Notice In order to prevent moisture from intruding it is recommended that after final setup the dip switch gets sealed with some silic...

Страница 7: ...Fig 1b Button for tare There are 3 internal LED s LED Color Action Description 1 yellow flashes measured values are present and are being outputted 2 red flashes chosen range has been exceeded 2 red lights up for approx 1 sec system is being zeroed tared after putting 24 Volts to clamp 4 pushing the button 3 green on Indicates internal supply voltage Notice In the case of a safety relevant applica...

Страница 8: ...sposed of separately Amplifiers and measurement units manufactured and sold by Althen Mess Sensortechnik GmbH serve B2B purposes only Therefore those old appliances must not be given to the communal disposer but must be given back to the seller or disposed of properly If you need any further information please contact your local authorities These measures serve to protect the environment and allow...

Страница 9: ...type Unitronic FD CP plus 3x2x0 25mm Housing EMC aluminum die cast Protection class IP66 Dimensions W x H x D 150x65x36 mm w o cable gland Weight ca 630 g incl 3 m Cable Electronics not encapsulated ca 1150 g incl 10 m Cable Electronics not encapsulated Storage temperature range 20 C 60 C Operating temperature range 20 C 60 C Order Designation NM1 ISU IP 3L 24 1 axis industrial inclination measure...

Страница 10: ...10 11 Component diagram ...

Страница 11: ...11 11 Housing dimensions Subject to modifications All information describes our products in general form ...

Отзывы: