6 Maintenance 

The flawless function and calibration of the whole measuring system is to be checked regularly. This 
inspection  is  also  necessary  after  every  repair  or  change  of  any  component  of  the  measurement 
system. 



7 Old appliances disposal 

 

According to european and german law, it is prohibited to dispose of old electronic 
devices into household waste, but must be collected and disposed of separately. 

 

Amplifiers  and  measurement  units  manufactured  and  sold  by  Althen  Mess-  &  Sensortechnik  GmbH 
serve B2B purposes only. Therefore, those old appliances must not be given to the communal disposer, 
but must be given back to the seller or disposed of properly. If you need any further information, please 
contact your local authorities. 

These  measures  serve  to  protect  the  environment  and  allow  recycling  and  recovery  of  valuable 
materials.  Furthermore,  do  electronic  devices  contain  substances  that  may  cause  damage  to  the 
environment if burned or dumped with normal household waste. 

 

 

 

Содержание NM1-IP-2L-420-B05

Страница 1: ...l France Althen DB Innovation Tél 0033 0 4 67 78 61 66 info althensensors fr Sweden Althen Sensors Control AB Tel 46 0 8 7 95 24 90 info althensensors de USA Canada Altheris Inc Sensors Controls Inc Tel 1 858 633 3572 info althensensors com Other Countries please contact us by email at sales althensensors com www althen de V2 1 eng Single Axis Tilt Measuring System ...

Страница 2: ...tion 5 4 Terminal Assignment 5 4 1 Supply Voltage 5 4 1 1 Load Impedance 5 5 Starting up 6 5 0 1 Description of measuring axis 6 5 1 Calibration of the tilt measuring system 7 5 1 1 Adjusting the zero point 7 5 1 2 Adjustment calibration of the amplifier 7 6 Maintenance 8 7 Old appliances disposal 8 Appendix 9 Datasheet 9 Order Designation 9 Housing Dimensions 10 EMC Mounting 11 ...

Страница 3: ...e The complete measuring unit must be protected against contact and influence of unauthorised persons In the case of a safety relevant application where a potential malfunction could cause damage to property or persons it is imperative that an additional independent monitor is provided In combination with sensors the maximum loads pressures etc must never be exceeded If you have reasons to assume ...

Страница 4: ...be connected to clean earth potential Please refer to the EMC Mounting Instructions in order to connect the sensor shields correctly To avoid possible potential equalization currents over the shield of the cable to the following evaluation unit this shield should be connected over a suitable capacitor 10 nF 200 V Overall the shield connections must be done properly to EMC standards as short as pos...

Страница 5: ...ctly suited for rough industrial environment Additionally the measuring system has been encapsulated to meet IP68 specifications and be better protected against vibrations 4 Terminal Assignment The electrical connection has been made via EMC cable glands and soldered inside The shield of the cable is connected to the housing Clamp Description Color 1 18 28 VDC red 2 Signal black 4 1 Supply Voltage...

Страница 6: ...signment The EMC mounting instructions are to be complied with System is to be powered up Allow the measuring system approx 15 minutes to warm up After levelling the system out 12 mA are to be adjusted If the range of adjustment should not be sufficient the mounting must be changed Both function and calibration are to be checked In order to ensure protection class IP68 the lid must be closed prope...

Страница 7: ...0 mA version 0 xx Notice The zero point adjustment range is approx 10 If this might not be sufficient the measuring object is to be re leveled 5 1 2 Adjustment calibration of the amplifier Before shipping the measuring system has been pre adjusted Using the potentiometer V should not be necessary Anyway if a re adjustment is necessary it is done as follows Level the measuring system with the help ...

Страница 8: ...sposed of separately Amplifiers and measurement units manufactured and sold by Althen Mess Sensortechnik GmbH serve B2B purposes only Therefore those old appliances must not be given to the communal disposer but must be given back to the seller or disposed of properly If you need any further information please contact your local authorities These measures serve to protect the environment and allow...

Страница 9: ...0 2 0 25 Electrical connections 3 m cable 2x0 25mm AWG20 other lengths on request Enclosure EMC aluminum die cast Protection class IP68 Dimensions W x H x D 98x38x63 mm w o cable gland Weight ca 550g incl 3m cable Storage temperature range 35 C 75 C Operating temperature range 20 C 60 C Order Designation NM1 IP 2L 24 420 1 axis measuring system Bxx Bidirectional xx inclination measuring range e g ...

Страница 10: ...10 12 Housing Dimensions ...

Страница 11: ...reen Use with cable screen Connect screen to ground with a ground clamp Amplifier Sensor Grounding case Case need to be mounted on a grounded surface 1st Step 2nd Step 3rd Step Skin cable Lay open the braid Lead cable through cap nut Establish cable in clamping put braid over clamping Braid have to overlap the o ring approx 2mm Put clamping application in Cable gland Tighten cap nut FINISHED ...

Страница 12: ...12 12 Subject to modifications All information describe our products in general form ...

Отзывы: