5 | 12
3 Technical Description
This single axis, industrial tilt measuring system, which consists of one none-contact sensor and an
electronic customized for said sensor, serves to measure accurate tilt angles in x-axis and it is intended
for side wall mounting. Depending on the version the tilt angle can be between ± 3 up to ± 60°, or
between 0 … 10° to 0 … 90°.
A standard analogue output of 4 … 20 mA is available for further evaluation.
The measuring system is contained a robust aluminium die cast enclosure which is perfectly suited for
rough industrial environment. Additionally, the measuring system has been encapsulated to meet IP68
specifications and be better protected against vibrations.
4 Terminal Assignment
The electrical connection has been made via EMC cable glands and soldered inside. The shield of the
cable is connected to the housing.
Clamp
Description
Color
1
18 … 28 VDC
red
2
Signal
black
4.1 Supply Voltage
The supply voltage can be 18 … 28 VDC.
It is to be noted, that the voltage determines the max load impedance. For instance: a voltage of 24
VDC allows a max. load impedance of 500 Ohms.
4.1.1 Load Impedance
The maximum load impedance depends on the supply voltage and is:
[18 VDC
=
200 Ohm]
24 VDC =
500 Ohm
[28 VDC
=