14 | 20
Appendix
Datasheet
Number of measuring axis:
1 (Version NM1)
2 (Version NM2)
Operating voltage:
10 … 18 VDC
18 … 30 VDC
Power consumption:
Max. 3 W (Version NM1)
Max. 4 W (Version NM2)
Analogue Output/Test Signal:
0 … 10 V / ±10 V
max 1 mA
4 … 20 mA
max 500 Ohms
Preferred measuring ranges:
± 3°, ±5°, ±10°, ± 15°, ±20°, ± 30°, ± 45°
Accuracy at 23°:
Up to ±15°:
±0,1°
Up to ±60°:
0,5% full scale
Up to ±65°:
on request
Electrical Connections:
M16x1,5 EMC-Cable screw connection on internal extension spring
Enclosure:
EMC aluminum-pressure enclosure (IP66)
Dimensions (W x H x D)
NM1: 175x80x57
NM2:160x160x91
Weight:
NM1: ca. 1000g
NM2: ca. 2300g
Storage temperature range:
-20°C … +60°C
Operating temperature range:
-20°C … +60°C
Order Designation
NM1-IP-4L…
NM2-IP-4L…
1-axis tilt measuring system
2-axis tilt measuring system
…-12E-…
…-24E-…
Operating voltage: 10 … 18 VDC
Operating voltage: 18 … 30 VDC
…-010-…
…-B10-…
…-020-…
…-420-…
Analogue output: 0 … 10 V; Zero-point at 5 V
Analogue output: ±10 V; Zero-point at 0 V
Analogue output: 0…20 mA; Zero-point at 10 mA
Analogue output 4…20 mA; Zero-point at 12 mA
…-V
Encapsulated Electronics and Sensor
Содержание NM1 4L Series
Страница 15: ...15 20 Housing Dimensions NM1 NM2 ...
Страница 17: ...17 20 Datasheet Accustar ...
Страница 18: ...18 20 ...
Страница 19: ...19 20 ...
Страница 20: ...20 20 Subject to modifications All information describe our products in general form ...