File: SM1150_r5eng - February 2007 - Technical note: SM1150
SM 1150
File: SM1150_r5eng - February 2007 - Technical note: SM 1150
page 15
of 29
SM 1150
[17]
ALARM
: entering this menu you get the name of the
last alarm occured
[18]
:
MAGN
Magnetron Overtemp.
Code 01
TEMP
Rack Overtemperature
Code 02
ARC
Arc Detector
Code 03
CURR
Overcurrent
Code 04
VOLT
Overvoltage
Code 05
AIR
Air Pressure Low
Code 06
H2O
Water Flow
Code 07
LOCK
Open Interlock
Code 08
LEAK
Current Leakage
Code 09
RACK
Rack Error
Code 10
MREV
Max Reverse Power
Code 11
POWD
Power Down
Code 12
The
Code number
is the number present on the 4 bits alarm
contacts (binary form).
Allarme
Codice
Descrizione
BIT 3 BIT 2 BIT 1 BIT 0
-------
0
No alarm
0
0
0
0
MAGN
01
Magnetron Overtemperature
0
0
0
1
TEMP
02
Rack Overtemperature
0
0
1
0
ARC
03
Arc Detection (on head)
0
0
1
1
CURR
04
Overcurrent
0
1
0
0
VOLT
05
Overvoltage
0
1
0
1
AIR
06
Air Pressure Low (on head)
0
1
1
0
H20
07
Water Flow Low (on head)
0
1
1
1
LOCK
08
Interlock
1
0
0
0
LEAK
09
Current Leakage on Ground
1
0
0
1
RACK
10
Rack Alarm
1
0
1
0
MREV
11
Max Reverse Power
1
0
1
1
POWD
12
Main Line Drop
1
1
0
0
RAM
13
RAM Memory Error
1
1
0
1
COM
14
Communication Interrupted
1
1
1
0
BIT ALARM TABLE
Содержание SM1150
Страница 19: ...page 18 of 29 File SM1150_r5eng February 2007 Technical note SM1150 SM 1150 ...
Страница 21: ...page 20 of 29 File SM1150_r5eng February 2007 Technical note SM1150 SM 1150 Pin out of conn 1 ...
Страница 22: ...File SM1150_r5eng February 2007 Technical note SM 1150 page 21 of 29 SM 1150 Pin out of conn 2 3 4 ...
Страница 23: ...page 22 of 29 File SM1150_r5eng February 2007 Technical note SM1150 SM 1150 Pin out of conn 5 ...
Страница 24: ...File SM1150_r5eng February 2007 Technical note SM 1150 page 23 of 29 SM 1150 Pin out of serials ...