Rip fence with DIGIT X
© ALTENDORF 2007
40
Basic settings of the display elektronics
Fig. 7-14: Display DIGIT X
The basic setting of the display electronics is re-
quired in order to adapt the measuring system tothe
individual machine situation. Check and, if ne-ces-
sary, re-enter the basic setting for each toolchange.
Knowing that the basic setting can only beper-
formed in conjunction with the tools actuallyused,
factory setting is not possible.
–
Push the rip fence to the left against mechani-
cal stop
–
Keep the F Key pressed while pressing RESET
–
Set the rip fence to 130 mm cutting width (flat
position)
–
Cut the trial piece and measure the workpiece
width using a sliding caliper
–
Press and keep the F key pressed, the right-
hand position of the display starts flashing after
3s
–
Use the + key to increase the value of the flas-
hing digit by 1 with each key actuation. When
exceeding the max. number value (9), the num-
bers start again with 0
–
The value of the flashing digit can be decreased
by 1 with each actuation of the - key.
–
Release the
F
key
–
The set dimensions is saved as a basic setting
value
Calibration the display elektronics
Calibration of the display electronics is required
when the fence position was change while the ma-
chine was switched off or when the saw blade was
changed.
–
Push the rip fence to the left against the mecha-
nical stop
–
Keep the F key pressed while briefly actuating
the RESET key. The basic setting value reap-
pears in the display
Switch dimension, mm and inch
–
Keep key + pressed for more than 3 s. The dis-
play will show inch (mm)
–
Release key +, the display electronics now
show the set dimension in inch (mm)