ALTECH Generation ALL IN ONE Type Heat Pump Water Heater Technical Manual
32
2.2.4.4 Mode Selection
a) The unit is enhanced with three operation modes, Economy Mode, Hybrid Mode and E-heater
Mode.
b) Economy Mode: The unit heats water only by compressor drive according to heat-pump principle.
Used when the ambient temp. is high.
c) Hybrid Mode: The unit heats water not only by compressor drive but also by electric heater. Used
when the ambient temp. is low or large amount of hot water is needed.
d) E-heater Mode: The unit heats water only by electric heater. Used when the ambient temp. is very
low.
e) By default, the unit operates in Hybrid Mode.
Change:
Press the MODE key, operation mode will
be shifted among the three modes in a
cycle,
meanwhile
the
corresponding
indicator on the display will light up.
2.2.4.5 Temperature Setting
Temp displayed is the water temp. in the upper part of the tank. Default is 55
℃
and the setting range is
38~60
℃
.
Method for set.
Press the"UP" and "DOWN" key, you
can increase and decrease the water
temp setting.
High Temp
When the setting temp is higher than 50
¡ æ
the Temp Operation Hign indicator will light
Содержание BT300i
Страница 13: ...V1 JUIN 2010 ALTECH Generation ALL IN ONE Type Heat Pump Water Heater Technical Manual 13 4 Dimensions ...
Страница 15: ...V1 JUIN 2010 ALTECH Generation ALL IN ONE Type Heat Pump Water Heater Technical Manual 15 7 Piping Diagrams ...
Страница 17: ...V1 JUIN 2010 ALTECH Generation ALL IN ONE Type Heat Pump Water Heater Technical Manual 17 9 Exploded View ...
Страница 43: ...V1 JUIN 2010 ALTECH Generation ALL IN ONE Type Heat Pump Water Heater Technical Manual 43 Wiring explanation ...