Technical Data

While temperature sensor connection breakdown 

VR

 is displayed, or while overrange 

SNB

 is displayed.

At this time, relay output are determined by 

PF1

 as shown in the parameter list.

6.5 Sensor Failure

WWW.ALTEC.CC

Sample rate

Measurement range

Resolution

Temperature sensor

Relay contact rating

Control algorithm

Power supply

Environmental

-50~150  °C

1  °C

NTC,  PVC  Wire,  2.0m

5(8)A/250VAC

125ms

ON/OFF

220V AC, 

2.0W

Temp:  -20~55  °C

,

Rel.  Humidity

:

85%

Dimensions

W78

H35

D78mm

×

×

Mnemonic

Parameter

Adjustable Range

Parameter

 

Description

SN

0~10

 

minutes

Compressor protection

6

RT1

Relay OUT2 min. off time

°C

1~25 

to limit 

KY1

's adjustable range

5

KYS

Hysteresis range

PF1

Indoor sensor
failure output

ON
0FF

OUT1 'ON' while sensor failure
OUT1 'OFF' while sensor failure

7

1

K,L

Indoor setpoint high limit

°C

20~50 

2

LOL

Indoor setpoint low limit

°C

0~20 

Operation parameter

Switch off the controller; press keys ▲ and ▼ and hold on, switch the controller on 

again. Parameter 

KYS

 appears on display. Parameter selection and the display of the 

value  is  obtained  by  pressing  key  S  repeatedly;  change  with  keys  ▲   and  ▼   and 

store with S.

6.4 Parameter List

6.3 Output Action

● 

When the indoor temperature T1  >  

K,L

, or T1 < 

LOL

, relay OUT2 will be ‘ON’ start 

the air conditioner to cool or heat.

●  

When the indoor temperature T1  >  

AL1

 and temperature difference(T1-T2) > 

DT

relay OUT1 will be ‘ON’ start the aeration fan to cool.

In order to avoid compressor switch off and on frequently, must set the minimum off 

time 

RT1

RT2 

between the switch OFF and switch ON, regardless of the input value.

PV

Out

ON

OFF

ON/OFF  Control  -  Cooling  mode

ON/OFF  Control  -  Heating  mode

K,L

KYS

PV

Out

ON

OFF

LOL

KYS

3

AL1

Aeration temperature

°C

0~50 

4

DT

Temp. difference setpoint

°C

1~25 

°C

-5~5

8

AD1

Indoor temperature 
sensor T1 adjustment

0~10

 

minutes

Compressor protection

9

RT2

Relay OUT1 min. off time

PF2

Outdoor sensor 
failure output

ON
0FF

OUT2 'ON' while sensor failure
OUT2 'OFF' while sensor failure

10

°C

-5~5

11

AD2

Outdoor temperature 
sensor T2 adjustment