background image

AL2094S Designers Guide

 

 

Doc. No. DG_2094E 

Altec Electronic AG  

Seite 12 / 30 

2.4 Modem-on-Hold 

The Modem-on-Hold (MOH) function (V.92 models only) enables the modem to place a data 
call to the Internet on hold while using the same line to accept an incoming or place an 
outgoing voice call. This feature is available only with a connection to a server supporting 
MOH. MOH can be executed through either of two methods: 

 

• 

One method is to enable MOH through the +PMH command. With Call Waiting 
Detection (+PCW command) enabled, an incoming call can be detected while online. 
Using a string of commands, the modem negotiates with the server to place the data 
connection on hold while the line is released so that it can be used to conduct a voice 
call. Once the voice call is completed, the modem can quickly renegotiate with the 
server back to the original data call. 

• 

An alternative method is to use communications software that makes use of the 
Conexant Modem-on-Hold drivers. Using this method, the software can detect an 
incoming call, place the data connection on hold, and switch back to a data connection. 

2.5 

Error Correction and Data Compression 

2.5.1  V.42 Error Correction 

V.42 supports two methods of error correction: LAPM and, as a fallback, MNP 4. The 
modem provides a detection and negotiation technique for determining and establishing the 
best method of error correction between two modems. 

2.5.2  MNP 2-4 Error Correction 

MNP 2-4 is a data link protocol that uses error correction algorithms to ensure data integrity. 
Supporting stream mode, the modem sends data frames in varying lengths depending on the 
amount of time between characters coming from the DTE. 

2.5.3  V.44 Data Compression 

V.44 data compression encodes pages and files associated with Web pages more efficiently 
than V.42 bis. These files include WEB pages, graphics and image files, and document files. 
V.44 can provide an effective data throughput rate up to DTE rate for a 56-kbps connection. 
The improved performance amount varies both with the actual format and with the content of 
individual pages and files. 

2.5.4  V.42 bis Data Compression 

V.42 bis data compression mode, enabled by the %Cn command or S46 register, operates 
when a LAPM or MNP 10 connection is established. The V.42 bis data compression employs 
a “string learning” algorithm in which a string of characters from the DTE is encoded as a 
fixed length codeword. Two 2-KB dictionaries are used to store the strings. These 
dictionaries are dynamically updated during normal operation. 

2.5.5  MNP 5 Data Compression 

MNP 5 data compression mode, enabled by the %Cn command, operates during an MNP 
connection. 
In MNP 5, the modem increases its throughput by compressing data into tokens before 
transmitting it to the remote modem, and by decompressing encoded received data before 
sending it to the DTE. 

2.6 

MNP 10 Data Throughput Enhancement 

MNP 10 protocol and MNP Extended Services enhance performance under adverse channel 
conditions such as those found in rural, long distance, or cellular environments. An MNP 10 
connection is established when an MNP 2-4 connection is negotiated with a remote modem 
supporting MNP 10. 

MNP Extended Services. 

The modem can quickly switch to MNP 10 operation when the 

remote modem supports MNP 10 and both modems are configured to operate in V.42. 

V.42 bis/MNP 5 Support. 

V.42 bis/MNP 10 can operate with V.42 bis or MNP 5 data 

compression. 

Содержание AL2094S Series

Страница 1: ...AL2094S Designers Guide Doc No DG_2094A Altec Electronic AG 1 30 Analog Socket Modem AL2094S Series Designer s Guide RELEASED 2 SEPTEMBER 2005...

Страница 2: ...or otherwise under any patent rights of Altec Electronic other than for circuitry embodied in Altec products Altec Electronic reserves the right to change circuitry at any time without notice This do...

Страница 3: ...Connection Speeds 10 2 2 9 Automode 10 2 3 Data Mode 11 2 3 1 Speed Buffering Normal Mode 11 2 3 2 Flow Control 11 2 3 3 Escape Sequence Detection 11 2 3 4 BREAK Detection 11 2 3 5 Telephone Line Moni...

Страница 4: ...y 27 6 2 1 Conditions for Maintaining Safety Compliance European Countries 27 6 2 2 Power Supply EN60950 1 2001 1 6 28 6 2 3 Clearances Creepage Distances and Distances through Insulation EN60950 1 20...

Страница 5: ...nd error correction V 42 MNP 2 4 modes are supported to maximize data throughput and data transfer integrity V 44 is a more efficient data compression than V 42 bis that significantly increases downst...

Страница 6: ...can be stored in internal SRAM Caller ID detect On hook Caller ID detection Off hook Call Waiting Caller ID detection during data mode in V 90 V 34 V 32bis and V 32 Distinctive ring detect Built in DT...

Страница 7: ...coming call is accepted by the user the user has a pre defined amount of time of holding the data connection for a brief conversation The data connection resumes upon incoming call termination The ser...

Страница 8: ...progress tone detection answer tone detection blacklisting caller ID and relay control are programmable SmartDAA technology allows a single PCB design and single BOM to be homologated worldwide Advan...

Страница 9: ...n V 17 fax mode the modem can sense speeds up to 115 2 kbps 2 2 Establishing Data Modem Connections 2 2 1 Telephone Number Directory The modem supports four telephone number entries in a directory tha...

Страница 10: ...be detected from a TTL compatible 15 3 Hz to 68 Hz square wave input 2 2 7 Billing Protection When the modem goes off hook to answer an incoming call both transmission and reception of data are preven...

Страница 11: ...ll Forward Fallback V 90 V 34 V 32 bis V 32 During initial handshake the modem will fallback to the optimal line connection within V 90 V 34 V 32 bis V 32 mode depending upon signal quality if automod...

Страница 12: ...n the amount of time between characters coming from the DTE 2 5 3 V 44 Data Compression V 44 data compression encodes pages and files associated with Web pages more efficiently than V 42 bis These fil...

Страница 13: ...ermination reasons remote phone line unplugged remote server modem shutdown For Voice applications this method can be used in addition to silence detection to determine when a remote caller has hung u...

Страница 14: ...abort dial attempt aborted by user Actions resulting from such failures can include specification of minimum inter call delay extended delay between calls and maximum numbers of retries before the nu...

Страница 15: ...d DTE interface signals are Serial Transmit Data input TXD Serial Receive Data output line RXD Clear to Send output CTS Received Line Signal Detector DCD Ring Indicator RI Data Terminal Ready control...

Страница 16: ...n No NAME Pin No NAME 1 GND 40 RXD 2 GND 39 TXD 3 VCC1 38 DTR 4 VCC2 37 DCD 5 EXTRESET 36 DSR DCD 6 NC 35 CTS 7 DSPKOUT 34 RTS 8 TDCLK 33 RI 9 RDCLK 32 NC 10 18 No pin 31 23 No pin 19 NC 22 NC 20 RING...

Страница 17: ...command mode RXD data represents the modem responses to the DTE CTS 35 O Ith Ot8 Clear To Send EIA CB ITU T CT106 CTS output ON low indicates that the modem is ready to accept data from the DTE In asy...

Страница 18: ...94S Modem I O Type Definitions I O Type Description It Ot2 Digital input 5V tolerant Digital output 2 mA ZINT 120 Itpu Ot2 Digital input 5V tolerant 75k pull up Digital output 2 mA ZINT 120 Ith Ot8 Di...

Страница 19: ...against damage due to high static voltages However it is advised that normal precautions be taken to avoid application of any voltage higher than maximum rated voltage An unterminated input can acquir...

Страница 20: ..._2094E Altec Electronic AG Seite 20 30 3 3 2 Interface and Timing Waveforms 3 3 2 1 Serial DTE Interface The serial DTE interface waveforms for 4800 and 9600 bps are illustrated in Figure 3 5 FIGURE 3...

Страница 21: ...recommended telco interface for U S Socket Modems is shown in Figure 3 3 The recommended telco interface for World Class Socket Modems is shown in Figure 3 4 TIP and RING signal traces are to be no cl...

Страница 22: ...ode Coke Epcos Microspire B82790 C0475 N265 ESC X1 M47 1S C1 C2 High Voltage Capacitor MLCC X2 Y3 Types Johansson Novacap Syfer 302R29W102KV3E LS1808N102K302 1808JA250102KCT F1 Fuse U S Models Europe...

Страница 23: ...s and component supplier application notes Seminars addressing noise suppression techniques are often offered by technical and professional associations as well as component suppliers 4 1 PC Board Lay...

Страница 24: ...itors Methods to decouple power lines are similar to decoupling telephone lines 7 Locate high frequency circuits in a separate area to minimize capacitive coupling to other circuits 8 Locate cables an...

Страница 25: ...cket to the host board and inserting the Socket Modem into the socket The second way is to solder the Socket Modem directly to the host board The most efficient way to do this is through a wave solder...

Страница 26: ...c Electronic AG Seite 26 30 5 5 P PA AC CK KA AG GE E D DI IM ME EN NS SI IO ON NS S Package Dimensions are shown in Figure 5 1 Figure 5 1 AL2094S Socket Modem Physical Dimensions 20 3 mm 3 5 mm 3 4mm...

Страница 27: ...signals Other components not intended for use with this design may affect the network access characteristics of the modem and may therefore invalidate the type approvals permits and or licences In bo...

Страница 28: ...rts of other assemblies inside the host b if applicable the PSTN connection traces TIP and RING routed through the host system motherboard and any other conductive area i e traces through holes SMD pa...

Страница 29: ...e host using or generating voltages greater than 300 V rms or dc advice from a competent telecommunications safety engineer must be obtained If these clearance and creepage distances cannot be provide...

Страница 30: ...EN 55024 1998 A1 2001 EN 61000 6 2 2001 industrial environment 6 3 2 Installation in Host Systems European Countries It is assumed that the Socket Modem will only assembled in host systems that comply...

Отзывы: