18. Service and  Certification

Service

Besides the repair of your instrument we offer the 

following additional services:

First diagnosis on the telephone or by e-mail

Call us or send us an e-mail and we will try to solve 

your problem. If this is not successful, please send 

us the instrument for repair.

Preventive maintenance, calibration, and 

recertification

For precautionary reasons we recommend 

regular preventive maintenance. We carry out 

this preventive maintenance automatically when 

you send us your instrument for maintenance 

and recertification. We clean the optics, check 

all functions, test and, if required, adjust the 

measured values by using reference standards. 

You will receive a certificate, which includes the 

retraceability to international standards.

Loaners

During the period of repair we furnish you with a 

loaner on request and availability.

Maintenance agreement

In case you want to make sure that the necessary 

maintenance is being done on a regular basis 

and on time, we recommend a maintenance 

agreement.

Extended warranty contracts

Furthermore, you can request an extended 

warranty contract for additional 12 months.

Ordering information:

SP-6801  Calibration service spectro-guide 45/0 

SP-6802  Calibration service spectro-guide 45/0 S 

SP-6834  Calibration service spectro-guide sphere 

SP-6836   Calibration service spectro-guide sphere S 

SE-6800  Extended warranty spectro-guide

Service and  Certification

Содержание BYK spectro-guide 45/0 gloss

Страница 1: ...Additives Instruments A member of Measure what you see spectro guide 45 0 gloss spectro guide sphere gloss Manual...

Страница 2: ...Geretsried Germany Tel 0 800 gardner 0 800 4273637 49 8171 3493 0 Fax 49 8171 3493 140 BYK Gardner USA 9104 Guilford Road Columbia MD 21046 USA Phone 800 343 7721 301 483 6500 Fax 800 394 8215 301 48...

Страница 3: ...erefore in addition to our products we offer many VALUE ADDED services Technical Sales Force Technical Application Support Application and Technical Seminars Repair Certification Service BYK Gardner i...

Страница 4: ...Calibrate 20 7 Measuring procedure 23 7 1 Measuring 23 7 2 Saving 24 7 3 Opening 26 8 Multiple readings 27 8 1 Storing the mean 29 8 2 Deleting the last reading 30 8 3 Number of readings 31 9 Display...

Страница 5: ...Beeper 51 10 6 8 Set time 52 10 6 9 Trigger adjustment 53 10 6 10 Language 54 10 7 Configuration 55 11 File 58 11 1 Open 58 11 2 Save 59 11 3 Delete 60 11 4 Mean 61 11 5 Print 61 12 Interface 62 13 S...

Страница 6: ...uipped with safety features Nevertheless read the safety warnings carefully and use the product only as described in these instructions to avoid accidental injury or damage No claims of product liabil...

Страница 7: ...danger of injury caused by electricity This sign points out additional information DANGER The term DANGER warns of possible severe injuries and danger to life WARNING The term WARNING warns of injuri...

Страница 8: ...under adverse conditions after harsh treatment during shipping Safety advices for batteries Do not crush or dismantle do not heat or incinerate do not immerse in any liquid This may cause explosion or...

Страница 9: ...pped bumped or shaken Avoid exposure to continuous humidity and con densation Avoid splashing with water chemicals or other liquids Please use only accessories that are available for the unit Only dev...

Страница 10: ...intend not to use the instrument for a longer period of time take out the batteries Additonal information on use You will find the technical data for all system components on the respective manufactur...

Страница 11: ...e observation angle is 0 With d 8 the sample is illuminated diffusely while the observation angle is 8 from the vertical Addi tionally 60 gloss is measured simultaneously Up to 1500 standards and 999...

Страница 12: ...alibration standard white calibration standard with certificate green checking reference high gloss standard sample area locator software easy link interface cable USB adapter batteries hand strap man...

Страница 13: ...for operation service The device runs on four AA 1 5 V alkaline or 1 2 V NiMH rechargeable battery Use only alkaline batteries or NiMH rechargeables AA LR6 Depending on the exact brand and the settin...

Страница 14: ...the used batteries Only alkaline cells of the type AA LR6should be used as new primary i e non rechargeable batteries If you prefer rechargeable batteries you can insert type AA NiMH batteries The si...

Страница 15: ...Battery Compartment 3 Measurement Aperture 4 Battery Compartment Release 5 Instrument Label with Serial Number 6 Operate Button 7 Cursor Buttons 8 Serial Interface Standard 9 Standard Box 10 Diaphrag...

Страница 16: ...the ideal place to store the accessories provided with the instrument The simplest way to operate the instrument is to grasp it from the side on which the battery compartment is located The thumb and...

Страница 17: ...selections You can use these buttons to move around in the main menu and open the desired sub menu The current position within a menu is indicated by a reverse display Options are selected from subme...

Страница 18: ...last measured standard appear on the right side At this point you can use the Operate button the large button to start the measurement of the sample As an alternative you can perform the measurement w...

Страница 19: ...Sample Sample Std Delete Last Smpl All Smpl One Std All Std Memory Mean On Off Del last Define N Print Standard Sample Online The framed menu options are not accessible in the basic version Display Sa...

Страница 20: ...Gloss on Gloss off Illum Obs A 2 A 10 C 2 C 10 D50 2 D50 10 D55 2 D55 10 D65 2 D65 10 D75 2 D75 10 Optionen lllum Obs F2 2 F2 10 F6 2 F6 10 F7 2 F7 10 F8 2 F8 10 F10 2 F10 10 F11 2 F11 10 U30 2 U30 10...

Страница 21: ...n the direction of the open lid and the front edge of the instrument is parallel to the edge of the lid This ensures that you will always perform the calibration under the same conditions The measurem...

Страница 22: ...ng instrument so that the display points in the direction of the open lid and the front edge of the instrument is parallel to the edge of the lid Press the Operate button You will then be instructed t...

Страница 23: ...standard and press the Operate button A beep will indicate that the measure ment has been completed Now place the instrument on the white standard and press the Operate button For gloss calibration pl...

Страница 24: ...s to the last measured standard As an alternative to the Operate button you can use the automatic trigger to perform the measurement To do this hold the instrument as shown in the accompanying illustr...

Страница 25: ...etter Enter any desired sequence of up to seven alphanumeric characters The last three positions are reserved for use as a combination of digits They are automatically incremented each time the measur...

Страница 26: ...rent ways to store a reading If you started the measurement with the button you can store it as a new standard with the Save Standard function If you started the measurement with the Operate button yo...

Страница 27: ...buttons to move the cursor to Sample Press the Operate button again The sample selection menu will appear Use the buttons to select the desired sample and press the Operate button The instrument retur...

Страница 28: ...ss the Operate button The submenu will open Choose on and press the Operate button to switch on the calculation of the mean In the default setting the mean is calculated based on three readings The di...

Страница 29: ...the Sample Mode option from the Display menu To do this use the buttons to place the cursor on the Display menu Then use the button to open the submenu Sample Mode is preselected Press the Operate but...

Страница 30: ...he sample name appears You can select the appropriate letter at the position indicated by the arrow by using the buttons Use the buttons to move the arrow to the next letter Enter a name After perform...

Страница 31: ...hen you press the Operate button Use the button to move the cursor to Del last and press the Operate button A prompt is asking whether you really want to delete the last reading If this is not the cas...

Страница 32: ...the Operate button The input menu for the number of readings appears The preset value is 3 You can use the buttons to select the appropriate digit at the position indicated by the arrow Use the butto...

Страница 33: ...rom the Display menu use the button to move the cursor to the Sample Mode option Press the Operate button and the display changes to Sample Mode The absolute values of the last reading are displayed i...

Страница 34: ...to Difference mode The data is displayed in accordance with the selected display setting The Smpl Dif setting is preset The following display options are also possible Std Dif Smpl Std To switch use...

Страница 35: ...Fail the tolerance Additionally a beep indicates when the result is Fail If the setting of individual components is selected in the configuration e g E L a b the expanded input screen appears You can...

Страница 36: ...If you like to change the tolerances for a standard you must open this standard and then store it again under the same name The input screen for the tolerances will then appear and you can change the...

Страница 37: ...en you press the Operate button the metamerism index for the individual illuminants appears on the display The display is determined by the selected illumination observer combination If D65 A or F2 ar...

Страница 38: ...he button to move the curser to the Illumin option When pressing the Operate button the instrument switches to the next illuminant which is displayed in the lower left corner Repeat this as many times...

Страница 39: ...s to browse through the menu and confirm the desired color system by pressing the Operate button The instrument returns to the previous measuring mode and the chosen color system is shown on the displ...

Страница 40: ...ons and confirm the required index with the Operate button The instrument returns to the previous measuring mode The selected index appears on the display Use the buttons to exit the submenu without c...

Страница 41: ...black background Then use the Operate button to measure the sample over the white background After measuring with the Std button the opacity is zero The L a and b values for the sample over the black...

Страница 42: ...d After measurement has been perfor med with the Operate button the color strength is displayed The display also shows the differences between the standard and the sample after theoretical color stren...

Страница 43: ...either save the measured value as Standard or as Sample See Chapter 7 2 When entering the tolerances you will also be prompted to enter a gloss range Enter the respective values and confirm your choic...

Страница 44: ...n you press the Operate button The illuminants which will appear on the display are indicated by check marks You can toggle illuminants on or off by moving the cursor to the illuminant and pressing th...

Страница 45: ...n the instrument so that the display points in the direction of the open lid and the front edge of the instrument is parallel to the edge of the lid Press the Operate button At this point you will be...

Страница 46: ...mber and name can be changed even when AutoStore is activated From the Option menu use the button to move the cursor to the Setup option The submenu will open when you press the Operate button AutoSto...

Страница 47: ...e and Pass Fail modes From the Options menu use the button to move the cursor to the Setup option In the submenu place the cursor on Auto Std and press the Operate button The toggled status is shown o...

Страница 48: ...tons to change the underlined digit Use the button to move the underline to the next digit End the input operation by pressing the Operate button The instrument returns to the measuring mode To end th...

Страница 49: ...ppears Use the buttons to change the underlined digit Use the button to move the underline to the next digit End the input operation by pressing the Operate button Having done this you are prompted to...

Страница 50: ...menu for the E94 ratio appears Use the buttons to change the underlined digit Use the button to move the underline to the next digit End the input operation by pressing the Operate button The instrume...

Страница 51: ...Setup option The submenu opens when you press the Operate button Move the cursor to the Disp Time option and press the Operate button The settings mask for the switch off time appears Use the buttons...

Страница 52: ...measurement is completed From the Options menu use the button to move the cursor to the Setup option The submenu opens when you press the Operate button Move the cursor to the Beeper option and press...

Страница 53: ...When you press the Operate button the input screen for the date and time appears Use the buttons to change the underlined digit Use the button to move the underline to the next digit The selection of...

Страница 54: ...the trigger appears When following the prompts the menu for adjusting the sensitivity of the measuring cone appears Use the buttons to move the bar When the bar is moved toward Lighter the trigger wil...

Страница 55: ...opens when you press the Operate button Move the cursor to the Language option and press the Operate button The language selection menu appears Use the buttons to select a language Confirm your select...

Страница 56: ...e functions of the basic and advanced version It is also possible to define two custom menus and store them The definition and selection of these menus are secured against improper access by means of...

Страница 57: ...o do this move the cursor to the Exit option This option appears in the Options menu in place of Configure Press the Operate button and the modified menu is stored The new instrument settings are take...

Страница 58: ...57 Setting Custom1 Setting Custom2 Options...

Страница 59: ...ds appear Use the buttons to select the desired standard then press the Operate button The cursor is always positioned on the standard which was selected most recently After the standard has been sele...

Страница 60: ...to select the appropriate letter at the position of the arrow Use the button to move the arrow to the next letter When you are finished with the input press the Operate button The menu for entering th...

Страница 61: ...or the standard name appears You can use the buttons to select the standard you wish to delete When you press the Operate button a prompt asks you to confirm that you want to delete the selected stand...

Страница 62: ...tandards are printed in the format Name Date Time Illuminant Observer Absolute Measured Values Tolerances Samples All stored samples are printed in the format Name Date Time Illuminant Observer Absolu...

Страница 63: ...easurement data can be transfered from the instrument s memory or directly after each reading to Windows applications The easy link program is included in the standard package for this purpose It cont...

Страница 64: ...erences of surface colours according to the CIELAB formula ISO 7724 Paints and varnishes Colorimetry ASTM D 2244 Standard Test Method for Calculation of Color Differences From Instrumentally Measured...

Страница 65: ...nd plastics ISO 2813 Paints and varnishes Determination of specular gloss of non metallic paint films at 20 60 and 85 ISO 7668 Anodized aluminium and aluminium alloys Measurement of specular reflectan...

Страница 66: ...tiles Color systems CIELab CIELCh Lab h CIELab99 XYZ Yxy Rx RyRz Color differences E E h EFMC2 E94 ECMC E99 E2000 Component differences Indices Yellowness YI E313 YI D1925 Whiteness WI E313 CIE Berge...

Страница 67: ...lian Spanish Japanese Chinese Display size 60 x 30 mm 2 4 x 1 2 in LCD 128 x 64 Pixel Display Absolute values differences Pass Fail Metamerism Power supply 4 AA batteries Alkaline NiCd or NiMH approx...

Страница 68: ...ed Delete standards which are no longer needed or transfer to the PC Sample Memory full The maximum number of samples 999 is already stored Delete samples which are no longer needed or transfer to the...

Страница 69: ...ult settings Standard memory and sample memory are not deleted To do the Instrument Reset press the buttons together until the message Reset Instrument appears Use the Operate button to confirm Instru...

Страница 70: ...sing dirty or damaged standards Since the surfaces of the standards are highly sensitive cleaning must be undertaken with great care To clean standards use a new lint free cloth dust free lens paper o...

Страница 71: ...uired adjust the measured values by using reference standards You will receive a certificate which includes the retraceability to international standards Loaners During the period of repair we furnish...

Страница 72: ...ardner USA 9104 Guilford Road Columbia MD 21046 USA Phone 1 301 483 6500 Fax 1 301 483 6555 China BYK Gardner Shanghai Office 3 F Building 22 No 140 Tian Lin Road Xuhui District Shanghai 200233 P R Ch...

Страница 73: ...sult of adapting the device to new information and improvements Copyright 2011 BYK Gardner GmbH All rights reserved No portion of the software documentation or other accompanying materials may be tran...

Страница 74: ...250 020 858 E 1105...

Отзывы: