background image

 

  

5

 

 

MT

X-

4

16

 -

P

R

O

G

R

AMMAB

LE

 4

x1

6

 IN

TE

R

C

O

M

 MAT

R

IX

RE

AR PANE

 

 

 

 

 

 

 

 

  

MAIN

S CON

N

ECT

OR AN

D F

U

SEH

O

LD

ER. 

U

SB

 CON

N

ECT

OR F

O

R COMPU

TER CON

TROL

  

 

 

 

PHOENIX

TM

 CON

N

ECT

ORS T

O

 CON

N

ECT

 

CON

ECT

ORES F

CC-68 DE EN

CADEN

A

MIEN

TO

 

THE

 IN

TE

RC

O

M

 LI

NE

S (

L1

 — L1

6

). 

DE

 UNI

D

A

D

ES

 

 

ID

C

 C

O

NNE

C

TO

R

 FO

R LI

NE

 E

X

PANS

IO

ID

C

 C

O

NNE

C

TO

R

 FO

R C

H

ANNE

L E

X

PANS

IO

N  

IN

 LI

NKE

D

 UNI

TS

IN

 LI

NKE

D

 UNI

TS

 

 

 

 

PHOENIX

TM

 CON

N

ECT

ORS T

O

 CON

N

ECT

 

 

THE INTERCOM CHANNELS (CH1 — CH4

). 

Содержание MTX-416

Страница 1: ...UDIOELECTRONICSDESIGN AUDIOELECTRONICSDESIGN AUDIOELECTRONICSDESIGN AUDIOELECTRONICSDESIGN EQUIPOS EUROPEOS ELECTR NICOS S A L Avda de la Industria 50 28760 TRES CANTOS MADRID SPAIN 34 91 761 65 80 34...

Страница 2: ...ERCOM AUDIO LINES CONNECTION 8 SYSTEM EXPANSION 9 COMPUTER CONNECTION 13 5 OPERATION 13 DISPLAY 14 DIRECT MEMORY RECALL SWITCHES M1 M5 14 MEMORY STORE SWITCH 15 MEMORY PREVIEW SWITCH 15 MEMORY CLEAR S...

Страница 3: ...ted lines The design incorporates input and output link connectors for easy X and Y expansion of number of channels and or lines An 8 channels to 32 lines matrix system can be done with 4 units The us...

Страница 4: ...and connectors that you can find in your ALTAIR matrix The description and explanation of each one will be found in the corresponding section FRONT PANEL DISPLAY NAVIGATION SWITCHES UP DOWN LEFT RIGHT...

Страница 5: ...TOR FOR COMPUTER CONTROL PHOENIX TM CONNECTORS TO CONNECT CONECTORES FCC 68 DE ENCADENAMIENTO THE INTERCOM LINES L1 L16 DE UNIDADES IDC CONNECTOR FOR LINE EXPANSION IDC CONNECTOR FOR CHANNEL EXPANSION...

Страница 6: ...lified service technician Do not place the unit close to heat sources 4 INSTALLATION UNPACKING Before leaving the factory each intercom matrix has been carefully inspected and tested Unpack and inspec...

Страница 7: ...supply male connector placed at the rear panel Insert the male connector of the tripolar cable into the mains plug Turn on the unit power switch In that moment all the leds of the unit will light sli...

Страница 8: ...1 CH4 REVERSE MODE 16 IN 4 OUT INTERCOM AUDIO LINES CONNECTION If the ALTAIR MTX 416 unit is used like intercom matrix we will connect the intercom lines L1 L16 to a unit with intercom passive channel...

Страница 9: ...all the intermediate situations Altogether we can link four units if we want to increase the line number we will link the units by means of the EXPANSION Y connector and if we want to increase the num...

Страница 10: ...10 MTX 416 PROGRAMMABLE 4x16 INTERCOM MATRIX 12x16 MATRIX 16x16 MATRIX...

Страница 11: ...11 MTX 416 PROGRAMMABLE 4x16 INTERCOM MATRIX 4x32 MATRIX 4x48 MATRIX...

Страница 12: ...12 MTX 416 PROGRAMMABLE 4x16 INTERCOM MATRIX 4x64 MATRIX 8x32 MATRIX...

Страница 13: ...rtical and exclusive mode so any intercom equipment connected to line 1 for example can be addressed exclusively to one of the 4 channels Power to the lines is taken from the 4 intercom channels and d...

Страница 14: ...we will select each channel to that line we want to connect it If we waited for a time without doing anything the edition mode will be reset and the LED will let blink If we pressed a switch that is n...

Страница 15: ...indicate M1 5 blinking the five leds of the direct memory recall switches will begin to blink as well as the LED corresponding to the STORE switch being indicated that we are in recording mode The un...

Страница 16: ...cted to one of the sixteen lines IN When pressing the REVERSE switch the display will indicate YES blinking as well as the LED corresponding to the REVERSE switch indicating that we are in reverse mod...

Страница 17: ...JP5 for the channel 3 and JP6 for the channel 4 placed at the left part of the main PCB near the rear panel looking at the unit from the front panel With the jumper placed the terminal impedance will...

Страница 18: ...18 MTX 416 PROGRAMMABLE 4x16 INTERCOM MATRIX 8 BLOCK DIAGRAM...

Страница 19: ...ns of the ALTAIR MTX 416 matrix reason why we have an open and flexible system being able to control remotely by means of matrix MTX 416 the configuration of the intercom lines in real time If we adde...

Страница 20: ...RECOMMENDED WIRE TYPE Shielded mic cable 2 x 0 30 mm2 CONNECTIONS 1 NO 1 NC circuit JACK RELAYS CONTACTS 0 5 Amp 125 VAC 1 Amp 30 VDC MAINS VOLTAGE 90 264 VAC 50 60 Hz POWER SUPPLY 12 VDC nominal 1 8...

Страница 21: ...nty expressed or implicit Any faulty unit must be sent to the dealer or the manufacturer The serial number of the unit must be included for any request to the technical service Equipos Europeos Electr...

Страница 22: ...nicos RAEE El logotipo de la Directiva RAEE se refiere a los programas y procedimientos espec ficos de reciclaje para aparatos electr nicos de pa ses de la Uni n Europea Recomendamos el reciclaje de...

Отзывы: