background image

 

 

 

16

 

 

DUAL/STEREO COMPRESSOR/NOISE GATE  CN-220

CAUTION:

 In Band Compressor mode, the headroom is more limited for what it is not advisable 

overcome the 16 dB of output level when we operate with negative adjustment of the output 
level control. 

 

STEREO SWITCH 

 

The stereo switch, allow us to select the unit working mode. With this switch 

depressed, the unit operation mode is DUAL, this permit us the treatment of two 
independent signals, adjusting each noise gates and compressor of independent 
mode. Upon pressing the switch, the channel 2 will be slave of the channel 1, for what the 
controls of the channel 2 will be disabled (except for the cases specified with the STEREO note: 
TEST MONITOR SWITCH, ACTIVITY LED’s, HP AND LP KEY FILTER CONTROLS and BAND 
COMPRESSOR SWITCH AND CONTROL, explained each one in their corresponding section).  

 

NOTE:

 In STEREO mode the signal that arrives to the noise gate and compressor detectors, is an 

average of the two input signals.  

 

SIDE CHAIN CONNECTOR 

 

In the noise gate and compressor normal operation, the input signal is 

used for the noise gate and compressor detector in order to carry out the noise 
gate triggers and compress the same input signal. This ¼” stereo JACK 
connector allow to use another signal (or the same input signal processed) in 
order to trigger the noise gate and compress the input signal according to the adjusted 
parameters.  

In order to introduce a signal different from the input signal, we will use a ¼” mono JACK , 

with the signal in the tip. 

If we want to process (equalise, expand, level change, etc.) the input signal, we will 

connect a ¼” stereo JACK , and we will obtain the input signal the ring, and we will return to the 
unit for the tip. 

The external control JACK connector input and output are unbalanced. 
The input impedance is 10 K

, and the output impedance is 220 

. The input and output 

SIDE CHAIN nominal level is - 3 dB. 

 

NOTE:

 In the Band Compressor mode, the external control is disabled. 

 

6. OPTIONS

 

 

In this section will explain the different available options for the unit. 

 
SECURITY COVER (TP-1) 

 

In some installation, it could be necessary to tamper proof the front panel controls avoiding 

unwanted or accidental manipulations. For this purpose, it is available as an option, a transparent 
plastic security cover. The installation is very easy, by means of two screws provided. 

 

KEY LOCKED SECURITY COVER (TS-1)  

 

In some installations it is necessary isolate the compressor/noise gate controls more 

securely than with the plastic security cover. For this extra protection, it is available an all-metallic 
and lockable security cover. This option cover fits into the four rack holes of the unit and includes 
rear nut-bars allowing the installation as a stand-alone unit.  

Содержание CN-220

Страница 1: ...220 COMPRESSOR NOISE GATE OWNERS MANUAL EQUIPOS EUROPEOS ELECTR NICOS S A L Avda de la Industria 50 28760 TRES CANTOS MADRID SPAIN 34 1 804 32 65 34 1 804 43 58 altair altairaudio com www altairaudio...

Страница 2: ...COMPRESSOR CONTROL AND SWITCH 14 THRESHOLD CONTROL 14 COMPRESSION RATIO CONTROL 15 GAIN REDUCTION VUMETER 15 BYPASS SWITCH 15 COMMON 15 OUTPUT LEVEL CONTROL 15 OUTPUT LEVEL VU METER 15 STEREO SWITCH...

Страница 3: ...trument control and mixing operation Special attention has been taken to provide the professionals with a general purpose device Specs such as 24 dBu max Input Output level operation and extremely low...

Страница 4: ...of them you will find in the corresponding section FRONT PANEL TEST MONITOR SWITCH BAND COMPRESSOR CONTROL AND SWITCH ACTIVITY LED s HP AND LP KEY FILTER CONTROLS THRESHOLD CONTROL BYPASS SWITCH THRES...

Страница 5: ...MPRESSOR NOISE GATE CN 220 REAR PANEL MAINS CONNECTOR FUSE HOLDER AND VOLTAGE SELECTOR EARTH LINK SWITCH OUTPUT SIGNAL CONNECTORS XLR 3 32 AND JACK SIDE CHAIN CONNECTOR JACK INPUT SIGNAL CONNECTORS XL...

Страница 6: ...shipment If any damage is found doesn t connect the unit to the mains notify the salesperson immediately because a qualified service technician must inspect the unit Save the original packing you cou...

Страница 7: ...position turned off Insert the female I E C connector of the tripolar cable into the unit power supply male connector placed at the rear panel Insert the male connector of the tripolar cable into the...

Страница 8: ...ion relying on the type of input signal balanced or unbalanced and according to the ground configuration of the equipment floating or ground referenced In the next diagrams we use the following symbol...

Страница 9: ...9 DUAL STEREO COMPRESSOR NOISE GATE CN 220 2 Using single conductor shielded cable BALANCED INPUT OUTPUT CONNECTION...

Страница 10: ...of the sound destination unit floating or ground referenced The next pictures shows some of the different possibilities of connection relying on the type of output signal balanced or unbalanced and ac...

Страница 11: ...2 Using single conductor shielded cable BALANCED INPUT GROUND LINK In some installations it might be necessary to isolate the compressor noise gate electric ground from the system mains earth in orde...

Страница 12: ...the audio equipment is limited by the levels of the internal operating voltages If the signal exceeded the internal operating voltages audible signal distortion is the result In practice this limitat...

Страница 13: ...through the noise gate STEREO In stereo mode the channel 2 activity LED s won t indicate the channel 2 noise gate operation The channel 1 activity LED s will indicate the operation of both noise gates...

Страница 14: ...ss this noise gate bypass switch the noise gate will be disabled and the controls and switched won t be operative The activity LED s continue working indicating our set up but the program signal will...

Страница 15: ...REDUCTION VUMETER The gain reduction produced by the input signal compression it is indicated in this vumeter allowing us in all moment the visualisation of the compressor action This vumeter is compo...

Страница 16: ...ut signal processed in order to trigger the noise gate and compress the input signal according to the adjusted parameters In order to introduce a signal different from the input signal we will use a m...

Страница 17: ...nt the signal split to the compressor and to the BAND COMPRESSOR controlled by their corresponding detectors The compressor and the BAND COMPRESSOR act on the GAIN REDUCTION vu meter in order to indic...

Страница 18: ...it breaks again check the overvoltage protections placed on the voltage selector If broken substitute them by an equivalent part 130 volts VARISTOR If the power supply fails it is necessary to check t...

Страница 19: ...errupted natural drum sounds With this application we will be used the two channels of the noise gate and two channels of the mixer console For key mic routing and patched gated signal Step 1 Set up t...

Страница 20: ...es place This effect could be reduced with the compressor limiter Adjust the compression ratio between 2 1 and 4 1 and immediately adjust the compression threshold until a good result is reached If ne...

Страница 21: ...UND PRESSURE LEVEL CONTROL The compressor limiter has a wide range of application in sound pressure level control of discos and pubs in order to warrant the maximum level authorised by the local autho...

Страница 22: ...the hall This procedure extensible to any frequency band can be a great resort for problems in the transmission of structures without having to reduce excessively the global level of the room because...

Страница 23: ...z unweighted Gate section in By pass Better than 98 dBu 20 Hz 20 KHz unweighted Gate section in SHUT state OUTPUT GAIN Variable from 15 dB to 15 dB Detent position at 0 dB FILTERS HPF 30 Hz 4 KHz LPF...

Страница 24: ...covered by this warranty There is no other warranty expressed or implicit Any faulty unit must be sent to the dealer or the manufacturer The serial number of the unit must be included with any reques...

Страница 25: ...nicos RAEE El logotipo de la Directiva RAEE se refiere a los programas y procedimientos espec ficos de reciclaje para aparatos electr nicos de pa ses de la Uni n Europea Recomendamos el reciclaje de n...

Отзывы: