background image

Please remove back plate carefully. Don‘t remove end caps.

Please fi x cable as required.

Make sure each wire is fi xed securely. 

For mounting please remove black and red wire. To remove it please press on 

top of cable gland of each wire and pull on each carefully.

Please fi x red wire on 

+

 and black wire on - with LED driver. Push cable gland 

top (red and black) with small screw driver and fi x cables accordingly.

Pull on each cable to make sure those are fi xed securely. 

Please place mounting plate on right position, mark fi xing holes.  

Use spacer washer between wall and mounting plate and screw 

fi xing plate to wall. ATTENTION! Fitting cannot be fi xed to uneven 

surface. Please make sure that plate is fi xed securely to wall. Clip 

in front part of fi tting. Front part has to be secured with safty wire. 

Safty wire cannot be removed and has to be fi xed all time.

(07) Front part has to be fl ush mounted. Push it hard to mounting plate till 

you can hear the „Click“. Please check that front part is fi xed securely. 

(08) 

Terminal with DALI and mains connection

Power supply: L= 1+N 230V AC

DALI: DA/L=2 / DA/N=3 

spacer  -

mounting example

02

03

04

05

01

07

08

Protective ground wire

Отзывы: