Alpine X-A70F Скачать руководство пользователя страница 9

8

-EN

 CONNECTION CHECK LIST

Please check your head unit for the conditions 
listed below: 

Remote Turn-On Lead

a.  The head unit does not have a remote turn-on 

or power antenna lead.

b.  The head unit’s power antenna lead is activated 

only when the radio is on (turns off in the tape 
or CD Mode).

c.  The head unit’s power antenna lead is logic level 

output (+) 5V, negative trigger (grounding type), 
or cannot sustain (+) 12V when connected to 
other equipment in addition to the vehicle’s 
power antenna. 

If any of the above conditions exist, the remote 
turn-on lead of your X-A90M/X-A70F/X-A90V 
must be connected to a switched power source 
(ignition) in the vehicle. Be sure to use a 3A fuse 
as close as possible to this ignition tap. Using 
this connection method, the 
X-A90M/X-A70F/X-A90V will turn on and stay on 
as long as the ignition switch is on.

If this is objectionable, a SPST (Single Pole, 
Single Throw) switch, in addition to the 3A fuse 
mentioned above, may be installed in-line on 
the X-A90M/X-A70F/X-A90V turn-on lead. This 
switch will then be used to turn on (and off ) the 
X-A90M/X-A70F/X-A90V. Therefore, the switch 
should be mounted so that is accessible by the 
driver. Make sure the switch is turned off when 
the vehicle is not running. Otherwise, the 
amplifier will remain on and drain the battery.

 Blue/White
 Power Antenna
 Remote Turn-On Lead
  To other Alpine component’s Remote Turn-On 

Leads

  SPST Switch (optional)
 Fuse (3A)
  As close as possible to the vehicle’s ignition tap
 Ignition Source

Amplifier

Содержание X-A70F

Страница 1: ...7 1200 ALPINE ELECTRONICS GmbH Wilhelm Wagenfeld Str 1 3 80807 M nchen Germany Phone 089 32 42 640 ALPINE ELECTRONICS OF U K LTD Alpine House Fletchamstead Highway Coventry CV4 9TW U K www alpine co u...

Страница 2: ...esult in an accident fire or electric shock USE THIS PRODUCT FOR MOBILE 12V APPLICATIONS Use for other than its designed application may result in fire electric shock or other injury USE THE CORRECT A...

Страница 3: ...moving parts like the seat rails or sharp or pointed edges This will prevent crimping and damage to the wiring If wiring passes through a hole in metal use a rubber grommet to prevent the wire s insul...

Страница 4: ...jects behind the surface that may become damaged during drilling 3 Drill the screw holes 4 Position the X A90M X A70F X A90V over the screw holes and secure with four self tapping screws Self Tapping...

Страница 5: ...er 2 Attach the Terminal Cover F based on the guide hole of the amplifier Push in until the hook is securely engaged Terminal Cover L Terminal Cover R Terminal Cover F Guide Hole e g X A90V 3 Peel the...

Страница 6: ...e fuse capacity of this machine see Battery Lead page 6 3 Connect all equipment to the same ground point while keeping wire length as short as possible 4 To securely connect the ground lead use an alr...

Страница 7: ...X A90M X A90V 90 amp fuse X A70F 70 amp fuse For details on the wires size to be used refer to the supplied Cautions on Power Supply Wires Connection and Cautions on Power Supply Wires page 19 and the...

Страница 8: ...on Power Supply Wires Connection and Cautions on Power Supply Wires page 19 and then use the wire of the specified size If the wire gauge used is unknown ask your dealer 2 Remove the insulation from...

Страница 9: ...e Be sure to use a 3A fuse as close as possible to this ignition tap Using this connection method the X A90M X A70F X A90V will turn on and stay on as long as the ignition switch is on If this is obje...

Страница 10: ...ut signal before being amplified This is desirable for several reasons To protect speakers too small or not capable of reproducing ultra low frequencies To minimize power wasted from reproducing inaud...

Страница 11: ...Knob X A70F X A90V only Use this control to adjust the crossover frequency between 50 and 400 Hz Input Channel Selector Switch CHANNEL 3 4 X A70F X A90V only a This switch setting is for selecting eit...

Страница 12: ...ier circuit is abnormal An electrical short has occurred or supply current is too high Turn off the power supply and eliminate the cause Then turn on the unit and verify that the indicator color has c...

Страница 13: ...ers Rear Speaker Subwoofer Dual Voice Coil Subwoofer RCA Extension Cable Sold Separately Speaker RCA Conversion Cable Sold Separately Y Adapter Sold Separately Subwoofer System 1 Subwoofer System 2 Su...

Страница 14: ...ase of using a series connection the lead wire of the Dual Voice Coil Subwoofer can be connected to either the terminal of the Speaker Connector Multiple Mono Amplifier System Connection example with...

Страница 15: ...old Separately For X A70F change the Input Channel Selector Switch setting according to the number of channels of the speaker input 4 Channel Input 2 Channel Input 3 4 1 2 4 Speaker System LO If the c...

Страница 16: ...15 EN 2 Speaker 1 Subwoofer System Bridged Connections Refer to 4 Speaker System page 14 2 Speaker System Bridged Connections Refer to 4 Speaker System page 14...

Страница 17: ...ut Channel Selector Switch setting according to the number of channels of the speaker input 5 Channel Input 4 Channel Input 2 Channel Input 3 4 1 2 SUB 1 2 3 4 4 Speaker Subwoofer System 1 Subwoofer S...

Страница 18: ...6 Parallel connection Series connection In the case of using a series connection the lead wire of the Dual Voice Coil Subwoofer can be connected to either the terminal of the Speaker Connector 2 Speak...

Страница 19: ...H2 Rear Speaker output L R to CH3 CH4 For the Speaker Input Level System setting connecting the Remote Turn On Lead is not required due to the REMOTE SENSING function of this product However the REMOT...

Страница 20: ...ernal Fuse Vehicle s chassis Vehicle s battery Amplifier Connection example when installing two amplifiers with a fuse capacity of 90 A and one amplifier with 70 A When the wire length from each ampli...

Страница 21: ...ef 10 W into 4 at 100 Hz 1 500 Control Input Sensitivity RCA Input Ref Rated Power into 4 Hi 0 4 10 V Lo 0 1 4 0 V Crossover Variable HPF LPF LPF 50 Hz 400 Hz 24 dB oct Variable Subsonic 8 Hz 40 Hz 24...

Страница 22: ...at 100 Hz 500 Control Input Select Selectable Input Signal Configuration 2ch 4ch Input CH 3 4 CH 1 2 or CH 3 4 Input Sensitivity RCA Input Ref Rated Power into 4 Hi 0 5 10 V Lo 0 2 4 0 V Crossover Var...

Страница 23: ...table Input Signal Configuration 2ch 4ch 6ch Input CH 3 4 CH 1 2 or CH 3 4 CH 1 2 3 4 or SUBWOOFER Input Sensitivity RCA Input Ref Rated Power into 4 Hi 0 5 10 V Lo 0 2 4 0 V Hi 0 4 10 V Lo 0 1 4 0 V...

Страница 24: ......

Страница 25: ......

Страница 26: ......

Страница 27: ......

Страница 28: ......

Отзывы: