![Alpine DVE-5207 Скачать руководство пользователя страница 31](http://html1.mh-extra.com/html/alpine/dve-5207/dve-5207_service-manual_2907654031.webp)
DVE-5207
NO.
VOLTAGE
NOTE
NO.
VOLTAGE
NOTE
1
6.73
1
0.01
2
3.01
2
4.91
3
0
3
4.94
4
0.01
4
3.39
5
0.01
5
0
6
0
NO.
VOLTAGE
NOTE
NO.
VOLTAGE
NOTE
1
0.01
1
8.04/0.01
2
4.94
2
0/8.03
3
4.97
3
8.04/8.04
4
4.87
4
0/3.35
5
0
5
0
NO.
VOLTAGE
NOTE
B
0/pulse
C
14.3/pulse
E
0
NO.
VOLTAGE
NOTE
B
12.53
C
14.38
E
11.9
NO.
VOLTAGE
NOTE
1
0.02
2
14.28
3
14.32
4
3.12
5
0
NO.
VOLTAGE
NOTE
1
0.01
2
4.91
3
4.97
4
4.91
5
0
[Measuring Conditions]
1. Power Supply Voltage
: DC14.4V
2. Measuring Meter
: Digital Multimeter
3. Measuring Point Reference : Between GND
4. Measuring Condition
: See each data
BZ off/on
POWER ON
POWER ON
ACC ON
Q860
Q859
Q858
Q857
Q806
Q805
Q861
Q862
ACC ON
BATT ON
POWER ON
Usually /
VMUTE2 ON
- 32 -