background image

 

SPECIFICATIONS 

 

Models: 

AT-304 PowerCode    868Mhz (art. code. 007045) 
AT-304 PG2/ PowerG 868Mhz (art. code. 007047) 
 

Suitable for: 

Visonic PowerCode   1-way 868MHz transmitters and detectors 
Visonic PowerG (PG2) 2-way 868Mhz transmitters and detectors 

 

 

RF MODULE 

 

Module:  

 

superhetrodyne RF-receiver 

Frequency: 

868,95MHz (broadband) 

 

 

DATA PROCESSING 

 

ID codes:  

 

More than 16 million possible combinations 

Length of transmission: 

36 bits 

 
MEMORY 
 
INPUT 
 
OUTPUT 
Relay: 
 
Open collector    

 
up to 16 wireless transmitters / detectors 
 
ARM input for status alarm system (ARMED/DISARMED) 
 
 
1 piece, max. 30VDC/1A 
 
3 pieces, max. 100mA 

 

 

ELECTRICAL 

 

Power supply: 

10-24VDC 

Consumption: 

Approx. 32mA 

 

 

ENVIROMENTAL 

 

Working temperature: 

0º C to 50º C 

Dimensions (L x W x H): 

108 x 165 x 38 mm 

 

 

 

INTRODUCTION 

The AT-304 is a universal 1-channel wireless receiver designed for receiving Visonic wireless (1-way) PowerCode 
868MHz devices or Visonic wireless (2-way) PowerG 868MHz devices. The devices can be panic buttons, keyfobs or 
various wireless detectors. A total of 16 wireless devices can be enrolled into the AT-304 receiver. 
 
The AT-304 receiver is equipped with 1 potential-free relay output and 3 open collector status outputs. The 
enrolled devices all activate the same relay output when the devices transmits a wireless signal to the AT-304 
receiver. The AT-304 PowerG (PG2) model also has an 'ARM' input which is used to indicate the status (ARMED / 
DISARMED) of a connected intrusion panel, this function ensures that connected PG2 motion sensors do not send a 
signal to the AT-304 receiver when the intrusion panel is disarmed and thus extending the lifetime of the battery. 
 
The AT-304 has a universal design and can be used with a wide range of Visonic wireless PowerCode or PowerG 
868Mhz devices. Due to this universal design the AT-304 is suitable for a variety of applications for example, the 
receiver can be linked to a nurse call system to activate a help call or linked to hard-wired inputs on an alarm 
system or alarm dialler to activate an alarm or transmit an alarm message to an ARC. By connecting various 
wireless devices, the AT-304 can be used for panic alarm, hold-up situations, burglary detection, fire detection, gas 
detection. The applications are endless. 
 
 

Содержание AT-304

Страница 1: ...Installation manual AT 304 1 channel wireless receiver 868MHz ...

Страница 2: ...CONTENTS SPECIFICATIONS 3 INTRODUCTION 3 ENROLLING TRANSMITTERS KEYFOBS AND DETECTORS 5 ERASING ALL TRANSMITTERS KEYFOBS AND DETECTORS 6 DIPSWITCHES AND LED s 8 ...

Страница 3: ... wireless devices can be enrolled into the AT 304 receiver The AT 304 receiver is equipped with 1 potential free relay output and 3 open collector status outputs The enrolled devices all activate the same relay output when the devices transmits a wireless signal to the AT 304 receiver The AT 304 PowerG PG2 model also has an ARM input which is used to indicate the status ARMED DISARMED of a connect...

Страница 4: ...sed buttons on the device The other buttons have no function If the AT 304 is used with a Visonic 1 button panic button MCT 101 MCT 201WP MCT 241 MCT 211 MCT 211RL MCT 220 PB 101 the relay output will be activated when the user presses the button Depending on the setting of dipswitch 2 the relay output will pulse for approximately 2 seconds or toggle If the AT 304 is used with a Visonic PowerCode ...

Страница 5: ...P12 LED will start to flash slowly 4 Now press the switch S1 the LEARN OP12 LED will now flash rapidly 5 PowerCode Press the button on the transmitter the keyfob or the tamper switch on a detector The device enrolls and the LEARN LED starts flashing slowly again PowerG Follow the steps in the manual of the PowerG device for the correct enrolment procedure For detectors in most cases an Enroll butt...

Страница 6: ...vice itself In order to enrol the PowerG device the ID code must first be deleted from the memory in the deivce For most PowerG detectors this is done by pressing and holding the Enroll button on the PowerG device until the enrolment LED on the device flashes RED once and then extinguishes Immediately after the red LED of the enrol LED flashes release the Enroll button The ID code of the PowerG de...

Страница 7: ...r This limits the amount of alarm transmission and extends the lifetime of the battery in the PowerG motion sensor The AT 304 receiver with pcb revision 1 3 and higher the pcb is equipped with an extra Arm input this input can be connected to an output of an intrusion panel that indicates the status ARMED DISARMED of the connected system When using the AT 304 PG2 the ARM input must be connected ot...

Страница 8: ...DIP switch 1 8 are set to OFF the LEARN LED will illuminate when an enrolled wireless component is received by the AT 308 receiver this way it can be visually checked whether a wireless component is being received WEEE declaration This Alphatronics product is manufactured with the most modern technology and consists of high quality devices Most of the devices used can be recycled The symbol means ...

Отзывы: