Parameter Value
Description
Default
36
dd
Time between 2 impulses [sec]
05
dd
– duration of delay between 2 impulses of relay [2 digits 00-99]
Combination 00 means time 0,5sec
5.3 Basic parameters
Parameter Value
Description
Default
41
p
Connection keyboard with
SlimDoorPhone
0
p
– connection SlimDoorPhone with keyboard,
p=0
disconnected,
p=1
connected
Rem: make a difference only in suppression and evaluate commands for
SlimDoorPhone
Parameter Value
Description
Default
42
o
Exit button control relay in
SlimDoorPhone
0
o
– select the relay, which has control from Exit button
o=0
control relay in keyboard,
o=1
control relay in SlimDoorPhone
Parameter Value
Description
Default
43
bb
Time of hold Exit button
00
bb
– min. time of hold necessary for exit button [2 místa 00-20]
step of the parameter is 0,5sec, its meaning, that
time in [sec] = Value of parameter / 2
for example. time of hold =
0 sec
enter value
bb=00
time of hold =
1
enter value
bb=02
time of hold
= 5,5 sec
enter value
bb=11
Parameter Value
Description
Default
44
z
Exit button reacts to disconnection
(switch off button)
0
z
– way of evaluation press Exit button
z=
0 switch on button (reacts to closure
)
z
=1 switch off button (reacts to open)