5.2 Relay
Parameter Value
Description
Default
31
m
Relay working in mode
m
1
m
– mode of relay [1 - 3]
m=1
mode
switch
- switch on by command or by password to adjusted time
(using for electric lock, open gate ...)
m=2
mode
two impulses
- switch on by command or by password on
adjusted time, past adjusted time is switch off and again switch on to
adjusted time (using electric movable gates - mode wicket)
m=3
mode
on- off
one command e.g . switch on, and next switch off, every
command negate previous state without time limitation
Rem after power failure is always switch off (like TV and etc.)
Parameter Value
Description
Default
32
rr
Relay closing time
rr
[sec] - command evoked
from keyboard
05
33
ss
Relay closing time
ss
[sec] - command
evoked from Exit button
05
34
tt
Relay closing time
tt
[sec] - command evoked
from SlimDoorPhone
05
rr / ss / tt
– duration of relay closing [2 digits 00-99]
Combination 00 means time 0,5sec
Parameter Value
Description
Default
35
vv
Time
vv
[sec] before closure relay - command
evoked from SlimDoorPhone
0
vv
–
Time
vv
before closure relay
[2 digits 00-99]
Combination 00 means time 0,5sec
Control relay from SlimDoorPhone consist of time before closure relay
vv
and from time closure of relay tt. This way is enabled set function gradual
opening door. In doorphone SlimDoorPhone set code for closure relay equal
code for closure relay in keyboard. After choice hereof code switch on relay in
SlimDoorPhone, time before closure relay
vv
in keyboard set delay before
closure relay in keyboard, after this time switch on relay in keyboard (second
door).