IPDP - installation and operating instructions
36
2. password for relay closing from buttons or keyboard [2 to 6 digits]. Total 6
passwords, they are controlled by Day/Night; the combination is entered
either by DoorPhone buttons (first 1/2 buttons) or from attached keyboard
(after pressing of key symbol). The relay closing influences the set switch
mode
and
Day/Night
switchover. By setting of choice mode of
2 number
groups
the DoorPhone is permanently in
DAY
mode.
By password choice some rules have to be observed:
Select passwords in way not to find its combination out from
wear of certain buttons by frequent use.
Select the first password button from frequentless button for
direct dialing (-extends choice time)(-not valid for keyboard).
Pay attention to congruity of password numbers when one
password includes other one, e.g. relay 1 has 1212 and relay 2
has 12121. Then after second pressing button 2 the only relay
1 is called, but password choice 212 for relay 2 can call both
relays after secon pressing button 2.
3. Command from phone after relay closing [2 digits]. The same command
can be set for both relays, then they are activated at the same time. The
advantage is to set the same command both for relay closing and
command to DoorPhone hanging up (page 33).
Single digit command is entered as the first character to replace with
"star" *. For example, 2-digit code to shorten it to 55 single-typing * 5 The
command is then evaluated with only one pressing 5 on the phone.
4. Duration of relay closing in second [2 digits 01-99]
5. To prohibit the control during incoming call is important e.g. when using
relay 2 in mode 1 for control of garage gate opening, when the electronics
opens the gate and the gate is closed by car passage. Then the control
from phone could undesirably cause the permanent gate opening (not
closed – no car passage).
6. time in second between close relays 1 and 2 by mode setting of relay 2 is
5
(gradual opening) [2 digits 01-99]
7. Default value – presetings to the firm settings. After making changes use
the save changes button.
Содержание Slim IPDP - 01
Страница 2: ......
Страница 9: ...IPDP installation and operating instructions 9 Picture 2 Connect Slim IPDP...
Страница 31: ...IPDP installation and operating instructions 31 3 1 11 Restart...
Страница 41: ......
Страница 43: ......
Страница 44: ......
Страница 45: ...JR 2008 11 version V6 1 VIII 11...