IP VarioBell
- installation and operating instructions
31
2.2 Connection of switches
Examples of switches wiring
can be found on the following page, they are
not covering all possible options for connecting the switches but give you
instructions on how to connect individual circuits (red rings with numbers =
numbers of the examples ).
1.
Basic wiring - 2 electric locks and the possibility of controlling two doors
independently (mode of switches 1 and 2 is monostable) - this scheme also
applies to the gradual opening of the door. This connection is the most
common, one common power source powers the IP-VarioBell and two
electric locks. The current load of the power supply depends particularly on
the type of electric locks used. The standard electric lock has a current
consumption of 0.6A - 1.0A, and it is also necessary to consider whether it
is probable that both switches of the electric locks will switch on
simultaneously. If not, the source of 1A is enough if you use low
consumption electic locks. In other cases please choose a power supply
source of 2A instead. If you use low consumption electric locks, the 1A
source is fully compliant.
2.
Two sources - the possibility to use independently two power supplies, one
for the IP-VarioBell and the other for electric locks. The electric lock 2 is
inversely connected (fire escape door).
3.
Combination of doors with electric lock and sliding gate in the fence.
4.
Extending the previous example to two doors with a gradual opening (this
function is set in the TimeRelay
– an external module)
5.
Combination of electric lock and auxiliary bell. The auxiliary bell switch can
be in the call switching mode (responding to all call buttons) or switching
the switch from the selected call button, then the switch responds to only
one selected call button.
6.
Switching lighting (e.g. way to the building) by the 1st switch (setting the
switch based on the call). The 2nd switch - control of weekly plan of e.g.
heating - the time profiles table synchronizes the selected switch. Attention!
A contactor must be used (the IP-VarioBell
must not
switch 230V!).
Examples shown on the figures below are just basic principles.
Содержание IP-VarioBell IPVB-00
Страница 2: ...Installation and operating instructions ...
Страница 3: ...IP VarioBell User instructions 3 ...
Страница 17: ...IP VarioBell installation and operating instructions 17 ...
Страница 24: ...IP VarioBell installation and operating instructions 24 ...
Страница 28: ...IP VarioBell installation and operating instructions 28 2 Installation 2 1 Assembly ...
Страница 30: ...IP VarioBell installation and operating instructions 30 Placing the IP VarioBell doorphone on the wall ...
Страница 32: ...IP VarioBell installation and operating instructions 32 ...
Страница 89: ......
Страница 91: ... Alphatech Technologies s r o 2014 2016 version V3 5 ...