Heatmaster 2

 

17 

hardare to allow the Mainboard to recognize this as a switching contact. Normally the pre-set 8 seconds 
should be plenty. The setting should only be changes if there are problems with the Mainboard. 
 

Display configuration 

 
Important note in advance: 
To use this feature a display must be connected to the data 
cable. The display must also allow brightness adjustments. 
Multiple displays will be able soon, for more information go to 

www.Alphacool.com

 

 
Brightness during operation: 
Here the brightness of the display lighting during operation can 
be set.  
 

Brightness in sleep mode 

Here the display brightness in sleep mode can be set 
(recommended setting: 0%)  
 

Brightness of stand-by lighting  

If no activity is detected, the display can be switched to stand-
by mode. We recommend reducing the brightness ion stand-by 
mode. 
 

Standby time

 

Here the period of time of inactivity after which the display will 
go into stand-by mode can be set. 
 

Fan configuration 

Here the fan channel for which the settings will be made can be  

 

Name 

It is possible to name every fan channel individually. The name 
may contain up to 255 characters made up of letters and 
numbers. 
 

Status 

Sets the mode of the fan between: Inactive, not connected and 
active  
 

Speed monitoring 

Here it can be set if the fan is equipped with a speed monitoring 
feature. This is usually only the case i fit is equipped with a rpm 
lead.  
 

Fan switch-off in case of failure 

If the fan is controlled by the Heatmaster to a target speed or 
voltage, but does not send a signal back, this feature will prevent 
the Heatmaster from trying to spin up the fan until the next 
system start-up. 
 

Action in case of fan failure 

here different alarm levels can be set. If the fan is a system-

critical fan it is often useful to set an alarm or even system shut-down here.  
 

Determine Min. / Max. speed 

We recommend determining the minimum and maximum speed once per each fan to allow the Heatmaster 2 
to determine the relevant data. If fluctuating values for maximum and minimum speed are to be expected, a 
check after every start-up can also be set. 
 

Содержание Heatmaster 2

Страница 1: ...Alphacool International GmbH Heatmaster 2 Operating Manual...

Страница 2: ...ation reserved Analog and digital reproduction of any kind except a copy of the end user customer requires the written permission of the Alphacool International Gmbh This manual is written according t...

Страница 3: ..._________________________________________________________ 9 PC shut down ________________________________________________________________________ 9 NTC 1 6 temperature sensors ________________________...

Страница 4: ...___ 18 Settings____________________________________________________________________________ 18 Temperature values __________________________________________________________________ 19 Pump flow rate s...

Страница 5: ..._______________________________________________23 TECHNICAL DATA _____________________________________________________23 DISPOSAL ____________________________________________________________23 APPENDI...

Страница 6: ...correctness of this data Regarding the type and extent of the order only the information provided with the order and order confirmation are determining 1 If a defect covered by the warranty occurs yo...

Страница 7: ...alled solidly in a free space in the enclosure Please make sure that the USB connector is connected with the correct polarity If the USB cable is connected with wrong polarity both the Mainboard as we...

Страница 8: ...age www Alphacool com Socket assignment Overview Power supply The Alphacool Heatmaster 2 is connected to the power supply via a 4 Pin Molex plug just like a HDD or optical drive Both voltage 12V and 5...

Страница 9: ...nels for pumps flow sensors aren t necessarily compatible with the according components This means that in some cases it is e g necessary to connect a 3 Pin plug to the pump flow sensor Please check i...

Страница 10: ...2 detects these after a reset The setting can also be made manually Water level To this input an analogue coolant level sensor can be connected With this sensor the Heatmaster is able to give a warnin...

Страница 11: ...rity may lead to destruction of the Mainboard and or the Alphacool Heatmaster 2 Now connect the power cable 4 Pin plug Be very careful not to damage the other components on the board Now connect the c...

Страница 12: ...d with the installation Choose the target folder for the installation Click on Install to proceed Setup_USB will copy the required files For the connection between PC and Alphacool Heatmaster 2 a spec...

Страница 13: ...ditions to proceed with the installation Click on Next to proceed Choose the target folder for the installation of the USB driver Click on Next to proceed Click on Install to proceed with the installa...

Страница 14: ...ck on Install to implement the hardware The setup will search for connected devices Confirm by clicking OK to complete the installation The driver installation is now complete Click on Finish to close...

Страница 15: ...s been installed the software can be installed To start the software setup open the file Setup_HM2 Choose the desired language The installation assistant will start Click on Next to proceed Accept the...

Страница 16: ...r 2 software Click on Next to proceed Choose a start menu folder Click on Install to proceed The Heatmaster 2 software is now being installed All settings are now made and the Heatmaster 2 software ha...

Страница 17: ...atmaster 2 This is especially important if multiple devices are connected e g in a server or network Temperature unit The temperature can be displayed in C or K The setting made here will be automatic...

Страница 18: ...et Fan configuration Here the fan channel for which the settings will be made can be Name It is possible to name every fan channel individually The name may contain up to 255 characters made up of let...

Страница 19: ...ible for the Alphacool Heatmaster 2 to maintain the set target temperature This is not an error or reason for reclamation but rather caused by the many possible settings of the Heatmaster 2 as well as...

Страница 20: ...to Off not connected or On Type Here the channel can be set to pump or flow rate sensor mode Factor This factor represents how many signals the pump flow rate sensor sends per revolution Normal flow...

Страница 21: ...determine the conversion factor for the water level in percent Online button relay configuration The online relay and button control allows highly complex adjustments to be made whilst the system is r...

Страница 22: ...stem The only requirement is an active stand by power supply as well as buttons and relays which will be available as accessories soon Please note that we have refrained from disabling settings which...

Страница 23: ...nteed that your system will always be protected Especially the automatic reboot feature on some Mainboards may lead to complications with the relay button configuration This greatly depends on the Mai...

Страница 24: ...m x 145mm Current draw max 6 3A Fan channel output power max 18W 38w aktiv cooled per channel Overall maximum output power max 75W overall Maximum relay channel power consumption max 5W per relay Disp...

Страница 25: ...tion in the world Expansion for analogue adaptor For special fans e g in the laboratory sector it is possible to connect an analogue expansion strip parallel to the existing fan channels This expansio...

Отзывы: