Disconnect from the main power supply before servicing the unit.

DO NOT pull out the power cord when the power is ON. This may cause serious 

electrical shocks which may result in fire hazards.

STOP using the ceiling fan when any abnormality or failure occurs.

Immediately stop using the ceiling fan and switch off the power supply. Please contact 

you authorized dealer for repairing and maintenance work

CAUTION

Please take note of the following important points when installing.

Safety cord should not be longer than the earthing conductor. 

Should failure of the suspension system occur, the supporting of the fan must not rely on 

the earthing conductor. The earthing terminal in the fan assembly should be such that 

should any part of the suspension system fall off, the body of the fan assembly shall 

effectively earthed.

Ensure that the unit’s panel is closed after service or installation.

Unsecured panels will cause the unit to operate noisily.

Sharp edges and coil surfaces are potential locations which may cause injury 

hazards. Avoid from being in contact with these places.

Before turning off the power supply set the remote controller’s ON/OFF switch to 

the “OFF” position.

If this is not done, the unit’s fans will start turning automatically when power resumes, 

posing a hazard to service personnel or the user.

Do not operate any heating apparatus too close to the ceiling fan unit or use in room 

where mineral oil, oil vapour or oil steam exist, this may cause plastic part to melt or 

deform as a result of excessive heat or chemical reaction.

Ensure the colour of wires of the outdoor unit and the terminal markings are same to the 

indoors respectively.

Don’t use joined and twisted wires for incoming power supply.

Do not place any object in the path of the blades. Avoid raising objects or your arms near 

the ceiling fan.

The installation instruction shall include the recommendation that the fan suspension 

system and blade screw tightening shall be examined yearly. This recommendation shall 

be written on the fan and on the regulator or permanently attached to the fan and to the 

regulator and be visible to user. The writing shall be legible and permanent.

Safety Precaution

2

Содержание Vannus VC 1

Страница 1: ...VC 1 INSTRUCTION MANUAL ...

Страница 2: ...river Blades that are detached from the unit during operation will cause serious injuries and property damages This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Chi...

Страница 3: ...locations which may cause injury hazards Avoid from being in contact with these places Before turning off the power supply set the remote controller s ON OFF switch to the OFF position If this is not done the unit s fans will start turning automatically when power resumes posing a hazard to service personnel or the user Do not operate any heating apparatus too close to the ceiling fan unit or use ...

Страница 4: ... Downrod Coupling Cover Motor Assembly Blade Transmitter Kit Transmitter Holder x 1 AAA AAA Battery x 2 Blade Screw Washer x 7 3 3 Assembly Kit 3 FAN ON FAN OFF 1 2 3 4 5 6 LIGHT ON F R LIGHT OFF 1H 2H 4H 8H ...

Страница 5: ...anopy Cover and Coupling Cover through the Downrod Step 2 Fix the Rubber assemble to the Downrod with Bolt Washer Nut and tighten them firmly then insert the Clevis Pin IMPORTANT Clevis pin MUST be insert to prevent nut from loosening Canopy Coupling Cover Bolt Washer Nut Clevis Pin ...

Страница 6: ...om the Downrod Place the Rubber Pulley onto the ceiling hook and fix back the Bolt Clevis Nut and Washer Tie the Safety Wire across the hook as shown and firmly screw the Safety Wire onto the Downrod Rubber Pulley Clevis Pin Nut Washer Bolt Safety Wire Safety Wire ...

Страница 7: ...n Yellow Green Yellow E Step 7 Connect the Connectors from Fan and Receiver Connect the wires from the receiver to House s Supply Wire Tighten Earth Wire back to Downrod and connect to House Supply Earth Terminal Step 8 Install the Blades on Motor with Screw Washer Install Switch Housing onto fan by twisting in Switch Housing ...

Страница 8: ...7 Below shows a complete installation diagram ...

Страница 9: ...8 ANT1 W N Pink Red Grey Neutral Blue Power Supply Live Brown Earth Green Yellow Earth Green Yellow Blue Brown Green Yellow MAIN PCB L E V U 220V 240V 50Hz 220V 240V 50Hz DC Motor ...

Страница 10: ...d into transmitter b Turn on the power supply wall switch to the fan c Within 30 sec press and hold the FAN ON button for 3 sec Once the receiver has detected the frequency transmitter will Beep Beep twice Programming process is completed and fan is ready to use If the fan is not responding to the transmitter repeat Step 1b Press and hold for 3 sec Transmitter Learning Process FAN ON FAN OFF 1 2 3...

Страница 11: ... fan fan will operate as the last setting Function of Forward Reverse Fan must be turned on and rotating Press F R button and fan will slow down and then change direction approx 15 sec When the fan is slowing down to change direction the Fan Speed function is disabled until direction has been changed Forward Fan rotates anti clockwise blowing the air downwards creating the wind chill effect Suitab...

Страница 12: ...VC 1 Max 185 Max 35W Motor Wattage Fan Width No of Blades 52 3 220V 240V 50Hz 11 ...

Страница 13: ...lan Molek 3 10 Taman Molek 81100 Johor Bahru Tel 07 353 4833 4933 Fax 07 355 4233 Melaka 19 19 1 19 2 Jalan KSB 11 Taman Kota Syahbandar 75200 Melaka Tel 06 292 6292 6293 Fax 06 292 6296 Perak 16 Jalan Tasek Timur Taman Tasek Indra 31400 Ipoh Perak Tel 05 545 2282 547 2282 Fax 05 547 6282 Penang 28 Jalan Icon City Icon City 14000 Bukit Mentajam Penang Tel 04 506 2366 2066 2566 Fax 04 506 2966 Paha...