Fig. 5.10
A
B
C
RESET
Fig. 5.9
A
B
C
RESET
DHW exclusion (
) -
With the boiler set up for DHW heating, press button
'C' momentarily to exclude the DHW heating mode operation. To return to the
DHW heating mode, press button 'C' again as shown in Fig. 5.9.
Fault records -
Press and hold button 'C' in to access the records of the last
8 faults that have affected the boiler (list from H i 0 to H i 7, where H i 0 is
the most recent fault). When you are in the menu, the screen will display, in
order, number 'bu 0', the number and code for the anomaly.
To scroll through the list, press the + and - buttons (as shown in Fig. 5.10).
To exit the menu, press and hold button 'C' in again.
Note:
Faults with the “FE” code are not saved in the fault records.
A
B
C
RESET
Information menu -
Press and hold in 'B' to access the information menu
containing all of the various information relative to the boiler operation.
Once you are inside the menu, you will momentarily see the parameter
number followed by the value.
To scroll through the various parameters, press the + and - buttons (as
shown in Fig. 5.11).
To exit the menu, press and hold 'B' in again.
While the parameter value is being displayed it is possible to momentarily
see the relative code again by pressing button 'A'. The viewable parameters
are listed in the following table.
Fig. 5.11
Alpha Pro Tec - Commissioning
Menu item
P01
P02
P03
P04
P05
P06
P07
P08
P09
P10
P11
P12
P13
P14
P15
P16
P17
Unit of measurement
µA
°C / °F
°C / °F
°C / °F
l / minute
%
RPM / 50
RPM / 50
°C / °F
-
°C / °F
-
°C / °F
°C / °F
-
-
-
Description
Flame current
Flow sensor temperature reading
Return sensor temperature reading
DHW sensor temperature reading (if installed)
System water flow (boiler circuit)
Operating power (burner modulation)
Fan speed requested by system
Current fan speed
Flue sensor temperature reading
Not used
External sensor temperature reading (if installed)
Not used
Flow temperature requested by system in heating
Flow temperature requested by system in DHW
Not used
Not used
Not used
Table of viewable parameters