Alpha MED-A64HE1 Скачать руководство пользователя страница 4

2

Safety Precautions

Before using this unit please read these operating instructions carefully. Take special care to follow the warnings 
indicated on the unit itself as well as the safety suggestions listed below. Keep these precautions at hand for 
future reference. 

Placement

- Avoid placing the unit in areas of:

•  direct sunlight. 
•  high temperature.
•  high humidity.
•  excessive vibration.
•  uneven surfaces. (Place the unit on a flat level surface.)

Such conditions might damage the cabinet and/or other component parts and thereby shorten the unit's service 
life.

Stacking

- Never place heavy items on top of the unit, the DC power supply unit, or AC power cord.

Voltage

-  Avoid the use of a “high voltage” AC power source. It is an extremely dangerous fire hazard.
-  A DC power source cannot be used. Be sure to check the power source carefully.
-  The working input voltage range is 90-264V AC.

Power Cord Protection

- Avoid using AC power cords with cuts, scratches, or poor connectors, as this may result in fire or electric shock. 

Excessive bending, pulling or slicing of the cord should also be avoided.

- Do not pull on the cord when you are disconnecting the power. This could cause an electric shock. Grasp the 

plug firmly when you disconnect the power supply.

- Never touch the plug with wet hands as a serious electric shock could result.

Foreign Materials

- Ensure that no foreign objects (e.g. - needles, coins, screwdrivers), accidentally fall into the unit. Otherwise, a 

serious electric shock, short circuit, or other malfunction could occur.

- Be extremely careful about spilling water or liquid on or into the unit, as a fire, short circuit, or electric shock 

can also occur. Disconnect the power plug and contact your dealer immediately if this occurs. 

- Avoid spraying volatile chemicals (e.g.- insecticides, alcohol, paint thinner) on or into the unit. They contain 

flammable gases which can be ignited.

- Insecticides, alcohol, paint thinner and similar chemicals should never be used to clean the unit. They can 

cause flaking or cloudiness to the cabinet finish.

Содержание MED-A64HE1

Страница 1: ...Product Manual MED64 Head Amplifier 64 CHANNEL HEAD AMPLIFIER P N MED A64HE1 A low noise multi electrode array system for in vitro electrophysiology...

Страница 2: ...mages resulting from the use of information contained in this document or from the use of programs and source code that may accompany it In no event shall the publisher and the author be liable for an...

Страница 3: ...e MED64 Main Amplifier to other Components 6 Signal Acquisition with the MED64 system 7 Amplifier Input Impedance Requirements for avoiding Signal Attenuation 7 Stimulation Using Planar Microelectrode...

Страница 4: ...ower cords with cuts scratches or poor connectors as this may result in fire or electric shock Excessive bending pulling or slicing of the cord should also be avoided Do not pull on the cord when you...

Страница 5: ...symbols used on equipment and documentation Environmental Conditions Indoor use Altitude up to 2000 m Temperature 5 40 C Maximum relative humidity 80 for temperatures up to 31 C decreasing linearly to...

Страница 6: ...livered via any of the 64 electrodes using the built in stimulator in the MED64 Head Amplifier Components and their functions Front panel 1 POWER Turns amplifier ON and OFF 2 STIMULUS CURRENT Selectio...

Страница 7: ...2 STIMULUS OUTPUT on the 64 CHANNEL MAIN AMPLIFIER MED A64MD1 5 CONTROL INPUT Input for control of stimulus channels Connects to the CONTROL OUTPUT on the 64 CHANNEL MAIN AMPLIFIER MED A64MD1 6 SIGNAL...

Страница 8: ...idified incubator It is connected with a cable as long as 2m without noise or signal attenuation The MED64 system does NOT usually require a Faraday cage or vibration isolation table necessary for con...

Страница 9: ...have very low impedances at 1kHz 10 k for 50 m electrodes 40 k for 20 m electrodes The impedances are small even at low frequencies as seen in Fig 2 Thus the input impedance of 100 M for the MED64 Hea...

Страница 10: ...field potentials Vf change according to the output current Is as seen on the right in the Fig 4 Stimulus Artifacts and Biphasic Stimulation During stimulation signals stimulus pulses are recorded at...

Страница 11: ...ositive components as seen in Fig 5 When biphasic stimulation is applied the electrode is charged and discharged quickly However when mono phasic stimulation is applied the electrodes need longer time...

Страница 12: ...s 50 000 pF for 50 x 50 m electrodes 22 000 pF for 20 x 20 m electrodes allowing stimulation with current amplitudes up to 200 A for 0 2 msec duration for each phase is 0 1 msec DO NOT use stimulus cu...

Страница 13: ...n maladjustment of user controls improper maintenance modifications or service by anyone other than AMS or damage attributable to acts of God Specifications Amplifier Stimulator General Power supply u...

Страница 14: ...ntific Inc Saito Bio Incubator 209 7 7 15 Saito asagi Ibaraki Osaka 567 0085 Japan Phone 81 72 648 7973 FAX 81 72 648 7974 http www med64 com support med64 com Manufactured by Alpha MED Scientific Inc...

Отзывы: