DOOR RELEASE DIAGRAMS - continued 

 

Set jumpers as shown in the chart below.  This configuration is used when a magnetic door lock has its own 
dedicated power supply. The PK407A only provides a dry contact which in this Normally Closed mode, allows 
voltage to flow to a magnetic lock through the B & A terminals. When the inside station 

DOOR

 Button is 

pressed, the relay opens the circuit, disconnecting the power and releases the door. Insure that proper polarity 
between the magnetic lock and its power supply is observed. 
The length of door release time is determined by the dipswitch settings (approx. 2, 10, or 25 seconds). 

 

 

 
 

   

 

 

USING THE 

PK407A 

ISOLATION 

RELAY  

for a 

MAG LOCK 

To use the PK407A as an isolation relay for a door strike with a separate power supply, the wiring and 
jumper settings are the same as above, except the wire going to the B terminal (Normally Closed) would go 
to the A terminal (Normally Open) instead. This way power from the IA543 would close the connection to 
apply power to the door strike and release the door. 

 

 

USING THE 

PK407A 

ISOLATION 

RELAY  

for a 

DOOR 

STRIKE 

Содержание IA543

Страница 1: ...operations integration into access control systems and Postal locks INSTALLATION PROCEDURE Read this manual to insure proper wiring component placement and installation methods WIRING REQUIREMENTS De...

Страница 2: ...a heavier gauge wire to reduce voltage drop ENTRY PANEL S Mount all entry panels in a suitable location protected from harsh weather and water Although many panels are weather resistant the more prot...

Страница 3: ...door strike when the inside station DOOR Button is pressed while also supplying 16VAC for system power Pay special attention to the transformer wiring and terminal markings The length of activation ti...

Страница 4: ...hat proper polarity between the magnetic lock and its power supply is observed The length of door release time is determined by the dipswitch settings approx 2 10 or 25 seconds USING THE PK407A ISOLAT...

Страница 5: ...allow the Postal Lock to release the door for 25 seconds independent of the 1 2 setting works only with 4 wire stations Dipswitch 6 when OFF will only allow the door to release for the time determine...

Страница 6: ...or Voice Volume and Tone Volume located through two access holes on the front cover Use a small screwdriver and do not use excessive force Carefully turn clockwise to increase the volume High volume s...

Страница 7: ...7...

Страница 8: ...ive visual indication notification enabling efficient operation of a busy office Wall or desk mounted master stations available in White Titanium or Brown Can be used to indicate room status emergency...

Отзывы: