COMPONENT INFORMATION 

 

APARTMENT STATIONS 

 

Locate stations in a convenient location. Recommended height is 60” A.F.F. for most applications. If inside    
stations are flush mount style, install proper back box or housing. Run appropriate wires with sufficient extra 
length for ease of service and installation. Avoid mounting near kitchen areas where cooking grime may build 
up. Avoid mounting near other electrical equipment that may cause electrical interference and static noise. 
 

 

AMPLIFIER 

 

Mount amplifier in a clean, dry area away from electrical equipment that could cause noise and interference on 
the system. Entry panel back boxes may be used to house the amplifier in some installations providing they 
will offer suitable protection from heat, dirt and moisture. Do not mount the power transformer within 3 feet of 
the amplifier. Check all wiring for shorts and grounds before applying system power. 
 
 

TRANSFORMER 

 

The transformer must be mounted in a clean, dry area, and in accordance with all applicable codes, at a 
distance of 3 to 80 feet (1 to 25 meters) from the amplifier using #18AWG wire. In cases where this distance 
must be exceeded, use a heavier gauge wire to reduce voltage drop. 
 
 

ENTRY PANEL(S) 

 

Mount all entry panels in a suitable location protected from harsh weather and water. Although many panels 
are weather resistant, the more protection you can provide, the longer the life expectancy will be. When 
mounting flush style panels, always use protective back boxes or appropriate housings. 
 
In the case of multiple entry systems, additional equipment, such as the IA502 or PK502B multi-entrance 
adapter, may be required. 
 
 

DOOR RELEASE 

 

The IA543 easily allows several door release configurations. Always use a minimum of #18AWG  2 conductor 
wire up to a maximum distance of 50 ft. (15 meters). In cases where this distance must be exceeded, use a 
heavier gauge wire to reduce voltage drop. 
 
Always run these wires separately from the entry speaker cable to prevent interference and noise. 
 
Special applications may require additional hardware such as the PK407A isolation relay, or RY502A Dual Door 
Timed Switcher Relay. 
 
Some applications may require a separate power supply for the door release device. Please refer to the next 
page for specific wiring and jumper positions. 
 

 

 

When running any audio wiring please make sure not to run too close to any source of electrical interference, such as 
fluorescent lights, ballasts, dimmers, other electrical wiring, electromagnetic interference (EMI), etc.

 

Содержание IA543

Страница 1: ...operations integration into access control systems and Postal locks INSTALLATION PROCEDURE Read this manual to insure proper wiring component placement and installation methods WIRING REQUIREMENTS De...

Страница 2: ...a heavier gauge wire to reduce voltage drop ENTRY PANEL S Mount all entry panels in a suitable location protected from harsh weather and water Although many panels are weather resistant the more prot...

Страница 3: ...door strike when the inside station DOOR Button is pressed while also supplying 16VAC for system power Pay special attention to the transformer wiring and terminal markings The length of activation ti...

Страница 4: ...hat proper polarity between the magnetic lock and its power supply is observed The length of door release time is determined by the dipswitch settings approx 2 10 or 25 seconds USING THE PK407A ISOLAT...

Страница 5: ...allow the Postal Lock to release the door for 25 seconds independent of the 1 2 setting works only with 4 wire stations Dipswitch 6 when OFF will only allow the door to release for the time determine...

Страница 6: ...or Voice Volume and Tone Volume located through two access holes on the front cover Use a small screwdriver and do not use excessive force Carefully turn clockwise to increase the volume High volume s...

Страница 7: ...7...

Страница 8: ...ive visual indication notification enabling efficient operation of a busy office Wall or desk mounted master stations available in White Titanium or Brown Can be used to indicate room status emergency...

Отзывы: