Alpha Dickson KT8P0 Скачать руководство пользователя страница 1

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Phone: 1-800-757-3747 or 1-630-543-3747 | Fax: 1-630-543-0498 | Email: [email protected] | Website:DicksonDate.com 

KT8P0, KT8P2, KT8P3 

8

” (203mm) Temperature Chart Recorder 

 

Quick Start 

 

1.

 

Remove the protective pen caps. 
 

2.

 

Connect Probes: Make sure the KTC probe is connected firmly to the Replaceable Sensor and that the Replaceable 
Sensor is plugged in firmly to the chart recorder. 
 

3.

 

Insert batteries and if applicable. 
• KT8P0: Four (4) AA batteries required 
• KT8P2/3: Four (4) AA batteries as back-up power only.  The unit will power on. 
 

4.

 

The instrument will move pen(s) to the appropriate readings.  
 

5.

 

Install the chart that matches the Dip Switch settings you have selected. 

a.

 Press the PEN HOME key to move the pens to the outside of the chart. The pen is automatically raised off the chart.  

b. 

Remove the old chart, place the new chart on the Chart Hub being certain that the edge of the chart slides under the 

Chart Guide Clip located at the outside of the chart.  
 

6.

 

Set the appropriate time. There are two ways to adjust the chart and set the appropriate time: 

 

a.

 Set the chart time manually by inserting a coin into the groove in the chart hub and turning clockwise until the correct 

hour (and day if applicable) on the chart is referenced to the timing arrow (just to the right of the pen tip on the dial). Press 
Pen Home to move the pen(s) back onto the chart. 
 

The following feature should be used for fine adjustments only:

 

b.

 To adjust the chart time, press and hold Adjust-Up and Adjust-Down buttons located on the back of the unit next to the 

dip switch.  
      The green LED will blink rapidly for about five seconds, then the LED will remain solid green. While in this state the 
Adjust-Up button will move the chart backward (counter clockwise) and the Adjust-Down button will move the chart forward 
(clockwise).  
      Rotate the chart until the correct hour (and day if applicable) on the chart is referenced to the timing arrow. Once you 
have set your chart, press the Pen Home button to exit Chart Adjust Mode. The unit will take one minute to exit the Chart 
Adjust Mode once Pen Home is pressed. Press Pen Home to move the pen(s) back onto the chart.

 

 

 

7.

 

Place the KT8 recorder on a flat vibration-free surface. Be sure it is in a vertical position and level. For best performance 
and longevity, the location should be a clean environment, free from dust and corrosive fumes. Do not exceed temperature 
specifications. Wall Mount: Keyhole slots are provided on the KT8 recorder for wall mounting.

 

 