background image

 

 

- 5 – 

Version 2.0 November 2008 

 

2

 

Important safety instructions 

 

2.1

 

Essentials 

 

For your own safety, and to prevent unnecessary damage to your equipment, 
observe the following safety instructions: 
 

 

2.2

 

General safety instructions 

 

The FALCON

®

 SPER

B

ER

®

 mini DMX 2000W is suitable exclusively for 

outdoor use*. 
 

*Its domestic use is not permitted. 

 
Incorrect handling may result in danger to life and limb resulting from heat, light, 
radiation, explosion, current, and falling objects. To avoid accidents, the generally 
applicable safety regulations must be known and followed. 
 

Before installing and using for the first time, read carefully through these 
instructions for use and follow the safety instructions given. 

 
 

2.3

 

Instructions relating to safety and use 

 

The safety instructions in these instructions for use are indicated with a hazard 
symbol. In addition, the gravity of the danger is indicated with a keyword. 
You must follow the measures described for hazard prevention. 
 

CATEGORY 1 SAFETY INSTRUCTION 

 
The keyword "Warning" indicates dangers which can lead to personal injuries up 
to and including death. 
 

 
DANGER TO LIFE DUE TO ELECTRIC CURRENT 

 
This symbol indicates the danger of an electric shock. 
 
 
 
 

CATEGORY 2 SAFETY INSTRUCTION 

 

The keyword "Caution" indicates dangers which can lead to material damage. 
 

Содержание FALCON SPERBER mini DMX 2000W

Страница 1: ...Instructions for use FALCON SPERBER mini DMX 2000W ...

Страница 2: ... 2 Version 2 0 November 2008 ...

Страница 3: ...UPPLY 9 3 2 FIXTURE CONTROL 10 3 3 ILLUMINANT 10 3 4 OPERATING CONDITIONS 11 3 5 INSTALLATION XENON ILLUMINANT 12 3 6 INSTRUCTION OF BEAM ADJUSTING 14 3 7 UNFOCUSSED BEAMS 15 3 8 FOCUSSED BEAM 15 3 9 CLEANING 16 3 10 TROUBLE SHOOTING 16 4 SYSTEM DESCRIPTION 17 4 1 TECHNICAL DATA 17 4 2 DMX 18 4 3 PHOTOMETRIC DATA 21 5 COMPANY AND MANUFACTURER DETAILS 22 5 1 CONTACT DETAILS 22 Before installing and...

Страница 4: ...pecial effects and lighting of events The searchlight which was developed particularly for these requirements is exceptionally versatile in the area of special light applications The illumination of buildings people living creatures or objects made of any type of flammable material is not permitted because of the very high intensity of radiation infrared heat and ultraviolet 1 2 Items supplied The...

Страница 5: ...n and followed Before installing and using for the first time read carefully through these instructions for use and follow the safety instructions given 2 3 Instructions relating to safety and use The safety instructions in these instructions for use are indicated with a hazard symbol In addition the gravity of the danger is indicated with a keyword You must follow the measures described for hazar...

Страница 6: ... not remove the lid of the casing under any circumstances Have your searchlight repaired and serviced only by specialists qualified and authorised by Alpha One GmbH Improper interference with the equipment can negatively affect the equipment s electrical safety Danger from burns and fire Every piece of equipment develops heat However the degree to which the equipment heats up is not dangerous Beca...

Страница 7: ...diately by a qualified technician The abovementioned faults increase the danger of an illuminant explosion Danger from falling objects For the correct use as a permanent installation it should be ensured that a solid sub construction is available at the point of use this should correspond to the requirements in the specification for the searchlight in terms of size weight and safety clearances to ...

Страница 8: ...ings in the equipment which are needed to allow heat to escape Never lean any objects against the equipment Maintain a clearance of at least 1 0 m around the equipment so that the heat which it creates can escape without hindrance Supply voltage Operate the searchlight only at the mains voltage shown on the manufacturer s plate Use only voltage supplies which correspond to the local and general sa...

Страница 9: ... first time the plug provided should be fitted only by a qualified person and in accordance with the applicable regulations The FALCON SPERBER mini DMX 1000W has an internal electronic power supply Models are available in various output classes and have connection requirements which correspond to the output classes FALCON SPERBER mini DMX 1000W Operating voltage Operating current Power requirement...

Страница 10: ...will also damage the internal electronics and the illuminant Replacement of the mains cable should be carried out only by trained and qualified specialist personnel 3 2 Fixture control F Page 18 of this manual 3 3 Illuminant O BER with the prescribed illuminant O can damage the fixture Exceeding the average operating times given by the manufacturer increases the risk of an illuminant explosion ATT...

Страница 11: ...ocking or covering the ventilation slits is not permitted and would inevitably result in the destruction of the illuminant and damage to the equipment Installation For the correct use in a permanent installation it should be ensured that a solid sub construction is available at the point of use this should correspond to the requirements in the specification for the searchlight in terms of size wei...

Страница 12: ... The illuminant can now be unscrewed from the illuminant socket by an anticlockwise turning motion After the illuminant has been placed safely in the protective packaging provided for this purpose the threaded brass socket must be removed from the cathode connection of the illuminant The socket is held in place by two M3 grub screws with Allen key heads When installing a new illuminant the brass s...

Страница 13: ...crew Head cover screw Head cover screw Head cover screw 2 Connect Anode adapter and Cathode adapter to the lamp Allen key needed Anode Adapter 3 Check if the reflector is clean Reflector 4 The installation of the new illuminant is made into the lower illuminant holder by means of a clockwise turning motion ...

Страница 14: ...he beam 3 6 Instruction of beam adjusting 1 Switch on the fixture 2 Use a 17mm wrench tool to adjust all three axis Use each screw several times to find the optimal focus point The adjustment will take maximum 2 minutes Beam Adjustment screw Attention The focus is pre adjusted so it is only necessary to turn the 17mm wrench tool only in small degrees steps without much energy to find the optimum f...

Страница 15: ... 15 Version 2 0 November 2008 3 7 Unfocussed beams Incorrect beam attitudes 3 8 Focussed beam On all axles optimized beam attitude ...

Страница 16: ...ains cable connected to the electrical supply Is the mains switch switched on Equipment is dead Circuit breaker is switched off Switch on the circuit breaker behind the inspection flap Circuit breaker trips Short circuit in the equipment Repair must be carried out only by qualified personnel Defective illuminant Repair must be carried out only by qualified personnel Ignition occurs but illuminant ...

Страница 17: ...of condensing Housing Material Aluminium Stainless steel service friendly design Colour Grey Silver RAL9006 Protection class IP 54 Illuminant Types OSRAM Xstage 2000W Average service life 1 000 h Colour temperature 6 000 K Reflector Material Stainless steel with high precision nickel rhodium dichroic coating Diameter 200 mm 7 87 inches Functions Lamp on off ignitable when hot strobe dimmer rotatio...

Страница 18: ...ntrolled over an external DMX512 signal The fixture must be connected to an external DMX512 control desk Before using the DMX start address must be selected with the external wired program unit the Control 1 DMX out DMX in Plug for program unit DMX program unit ...

Страница 19: ... alpha one logo appears in the display After pressing the M button the actual DMX start address appears in the display After pressing the M button the main menu appears in the display After pressing the down button the displays show inverted DMX SetUp appears in the display ...

Страница 20: ...lay After pressing the Enter button the display shows the actual DMX address in the display DMX start address can be changed by pressing the up or the down buttons After pressing the E button the new DMX start address will be saved After pressing the M button two times the main menu will be back in the display ...

Страница 21: ... 21 Version 2 0 November 2008 4 3 Photometric data ...

Страница 22: ...de mail info alphaone gmbh de The publisher retains all rights in this document The document may not be copied or reproduced in part or in full without the express written permission of the publisher All illustrations drawings and other incorporated media which have been used are subject to the law of copyright Copyright alpha one GmbH 2008 We reserve the right to technical modifications ...

Страница 23: ... 23 Version 2 0 November 2008 ...

Страница 24: ...Attachment 3 Handling OSRAM XBO 24 Version 2 0 November 2008 ...

Страница 25: ... 25 Version 2 0 November 2008 ...

Страница 26: ... 26 Version 2 0 November 2008 ...

Отзывы: