Page 6
Eagle 250 Service Manual
Rev. 01
AM-138 Board Jumpers
Jumper
Number
Jumper Name
Default
Setting
Notes
JP1
RR-EN
out
When IN, enables remote reset through serial
port 0 (this is not supported through AM-90
card); when out, allows remote reset cable
attachment at P8. See page 8.
JP2
Level7 Select
UPS
3-pin jumper; set to two pins at UPS side. When
set to FP, front panel Turbo switch enables
Level7 diagnostic. Not user configurable.
JP3
20
16
IN
out
Ethernet bus clock select. Not user configurable.
JP5
TERMPWR
EN
SCSI bus termination voltage,
EN = Enabled, DS = Disabled. User may change.
JP6
DISC
IN
Not user configurable
JP7
Memory Size
Select
See Table 4.
Memory size configuration. Installer must
configure.
JP8
32
16
25
20
33
out
out
out
out
IN
Not user configurable.
JP9
33
50
66
SP
out
out
IN
out
Not user configurable.
Table 1: Jumper Configuration for the AM-138 Board