background image

21

Product name.

ALPHA 3060

ex

Master

#Last

#1

#2

#3

Extra Function 

– Sleep Mode / Master / RDM / Dimming Speed

-  Remove 'DMX in' cable.
-  Set ‘

Master 

Enable

-  Set the same 

channel mode.

-  Operation After setting.

-  Connecting 

'DMX in & out' cable.

-  Set ‘

Master 

Disable

-  Set the same 

channel mode.

-  No operation 

after setting.

Master Setup

  

The master slave function allows to synchronize and control all connected lighting 

fixtures through the DMX signal without a console connection.

  

If a problem occurs in the console or communication line, it is possible to control 

the brightness and CCT and color with only the lighting fixture. 

  

Main screen

 

 

Setting

 

 Touch MASTER SETUP, the function turns on.

 (2 Touch)

  

Functions available with one setting of the first lighting fixture.

 Main Screen 

 Fixture ID Screen 

Touch!

Touch!

DMX cable connect

Содержание 3045

Страница 1: ...A L P H A 3 0 6 0 A L P H A 3 0 6 0 A L P H A S E V E N C O L O R ALPHA LITE ALPHA LITE USER MANUAL USER MANUAL BOOK BOOK ...

Страница 2: ...safety chain on the product when installing and moving Please install the signs below for people to bypass when install the product on high truss The work should be done under the direction of approved specialist who is trained in safety and mechanical installations The brightness and color temperature before and after aging may be different 2 3 4 5 6 1 Precautions Product name ALPHA 3060 ...

Страница 3: ... 17 18 19 LCD Screen Instruction Safety Information 1 Sleep Mode Function RDM Function Dimming Speed Setup Master Function Fixture ID Number Setup Fixture Label Setup 20 21 22 Extra Function Temperature Sensor Network Connection 23 Error Information Cross Fader Color Macro 24 Extra Information DMX Protocols RDM Protocols 25 28 Protocols Fixture Information Fixture Exterior View Dimensions Accessor...

Страница 4: ...neration of LED lighting with a new light source optical solution for lighting control and an innovative operation interface It is a package lighting composed of LED spot LED panel with 6 Color 2 White ultra high capacity LED engine and ALPHA LITE s unique α Algorithm Overcome the limits of the color expression gamut and color temperature range that existing White lighting and RGB lighting it beca...

Страница 5: ...4 ALPHA LITE USER MANUAL BOOK Fixture Exterior View Fixed Knob Yoke Smart Touch LCD Screen Handle Connector Panel ...

Страница 6: ...5 Product name ALPHA 3060 Dimensions ...

Страница 7: ...6 ALPHA LITE USER MANUAL BOOK Accessory Options Pole operation yoke Pan Tilt Soft box Detachable Honeycomb Detachable ...

Страница 8: ...tocol DMX512 RDM Optional Supported Protocol DMX512 Wireless RDM Wireless Remote Device Management Supported Channel Function Dimming CCT Tint RGBALC Cross Fader Color Macro Strobe Power Input Voltage AC 100 240V 50 60Hz Power Consumption W 450 Ambient Temperature Operation C 20 45 Spigot Mounting mm 16 28 Tilt Angle 90 Body Dimensions mm inch WHD 708 x 390 x 192 27 9 x 15 4 x 7 6 Full Dimensions ...

Страница 9: ... 7m 9m Front side Micro Lens 115 1153 450 245 163 Flip Side Micro Lens 85 1537 560 291 178 5600K 5600K Lens System ALPHA 3045 ex Photometry Data Multi Array Lens Micro Beam Shaping Film Micro Diffuser Distance m Illuminance lux Illuminance lux ...

Страница 10: ...sert the bottom of the Barndoor into the top groove of the body 1 3 2 4 Fit the bolt at the top of the Barndoor to the groove Lower the Barndoor down along the groove Turn the bolt clockwise to fix the Barn door Barndoor Assembly ...

Страница 11: ...en replacing the diffuser lens insert the soft side facing inward The rough side is the front Pull the latch toward the back of the body Take out the diffuser lens on the left Replace the diffuser lens by pushing it sideways 3 2 1 When replacing the diffuser lens insert the soft side facing inward The rough side is the front ALPHA 3060 Image example Diffuser Lens Change ...

Страница 12: ...TOR ONLY Do not connect USB without administrator s permission 1 Observe the proper voltage rang 2 If power is supplied outside the range noise may be generated from the SMPS 3 If the operating voltage is out of the proper voltage range SMPS function may be degraded or damaged WARNING IN OUT IN OUT IN OUT IN OUT IN OUT Connect 01 Start connection Connect 02 Connect 03 Max Connect 8 Connect 07 Reco...

Страница 13: ...X chain User must use an adapter cable for connect the DMX controller to other XLR output Shield Signal Signal Not Connected Not Connected Shield Signal Signal Not Connected Not Connected DMX INPUT XLR Mounting plugs DMX OUTPUT XLR Mounting sockets 1 Connect the DMX output of the first lighitng fixture in DMX chain to the DMX input of the next fixture 2 Connect one output to the input of the next ...

Страница 14: ...n the fixture is turned on the Smart Touch screen automatically locked To unlock the touch screen touch the finger icon three times If you do not touch for 30 seconds the lock is reset Main Screen Locked Fixture ID Screen Locked A A A x 3 x 3 ...

Страница 15: ...Adjust the selected function among Intensity Color Temperature and Tint In DMX MODE Current channel mode Display current channel mode Only display on DMX MODE 08 Home Return to the main screen 09 DMX512 Mode Address Setup Set channel mode and DMX512 address 10 User Mode Setup Set Intensity CCT and Tint manually 11 Color Mode Setup Set RGB lighting color Saturation and Intensity 12 Setting Setting ...

Страница 16: ...information DMX address input Color temperature setup Saturation setup Master function setup Information Tint setup White setup RDM mode setup DMX channel value Description of each function Individual RGB setup and Preset RGBW value Description of each function Description of fixture ID Information Full screen Dimming speed setup Information Information Fixture ID number input Information Home Mai...

Страница 17: ... bottom the current lighting value and fixture temperature are displayed and some lighting value can be adjusted on the main screen by touching the value DMX MODE USER MODE COLOR MODE HOME DMX MODE USER MODE COLOR MODE INFO Product model name firmware version UID number current temperature of equipment usage time of equipment LED usage time website manual download link etc by clicking the INFO but...

Страница 18: ...3 3 Ch Mode Dimming CCT 5 5 Ch Mode Dimming CCT Tint Cross Fader Color Macro 12 12 Ch Mode Dimming CCT Tint Cross Fader Red Green Blue Amber Lime Cyan Color Macro Strobe Support channels and features vary by product information DMX Mode Channel Change Address Setup DMX MODE It is used to adjust value by DMX512 signal In DMX512 MODE screen user can select DMX channel mode on top tap Input DMX512 ad...

Страница 19: ...nt OR In DMX mode even if you press the current value on the main screen the bottom bar is not active Activate control bar and adjust value directly according to selected function To return to the previous screen press the INFO button again Intensity The number indicates the current brightness value of the fixture and is displayed from 0 to 100 CCT The number indicates the current color temperatur...

Страница 20: ...and is displayed from 0 to 100 White The number indicates the current White LED brightness value of the fixture and is displayed from 0 to 100 information COLOR MODE COLOR MODE It is used when the user directly manipulates the equipment COLOR MODE screen Touch the function you want to change Active in Orange Adjust the value with touch or drag Individual RGB value adjustment and saving preset 1 9 ...

Страница 21: ...Sleep mode setup Default Off The function to automatically turn off the screen when there is no operation for 30 seconds If OFF it is always on the screen while power is on Master setup Default Off The function to synchronize and user control all connected fixtures without a console connection If OFF the DMX signal will follow RDM setup Default On The function to enable two way wireless communicat...

Страница 22: ...r Setup The master slave function allows to synchronize and control all connected lighting fixtures through the DMX signal without a console connection If a problem occurs in the console or communication line it is possible to control the brightness and CCT and color with only the lighting fixture Main screen Setting Touch MASTER SETUP the function turns on 2 Touch Functions available with one set...

Страница 23: ...tered contents are displayed in the upper left corner Move to fixture management number setting screen FIXTURE ID HOME Move to input screen that can change the number Input the desired number 001 to 9999 and press Enter Move to the FIXTURE ID screen that displays the large size entered value Touch HOME icon to go back to the main screen The fixture ID is displayed in 3 or 4 digits from automatical...

Страница 24: ...ease Check Device will be displayed The error messages are only displayed on the main screen and the fixture ID screen Even if the temperature falls to the normal range It does not disappear In this case normalize the temperature of the equipment and restart it Detects the temperature of the current fixture LED source housing and displays it on the Smart Touch LCD screen When the DMX512 network co...

Страница 25: ...e the last set color among Ch 5 10 Individual color settings and Ch 11 Color Macro is applied and distributed As the DMX value of Ch 4 increase the brightness of Ch 2 decrease and the brightness of the color set by Ch 5 or Ch 5 11 increase at the same time The DMX value of Ch 4 adjusts the CCT and color brightness and density ratio relative to each other Cross Fader Color Macro 100 0 0 255 Cross F...

Страница 26: ...100 Cyan 11 0 255 See DMX Protocols 4 Color Macro 12 0 255 Strobe Mode Channel DMX Value Function 5 1 0 255 0 100 Dimmer 2 0 255 See DMX Protocols 2 Color Temperature CCT 3 0 119 120 255 See DMX Protocols 3 Tint 4 0 255 0 100 Cross Fader 5 0 255 See DMX Protocols 4 Color Macro Mode Channel DMX Value Function 3 1 0 255 0 100 Dimmer 2 0 255 See DMX Protocols 2 Color Temperature CCT 3 0 119 120 255 S...

Страница 27: ...6 5900 117 118 5950 119 120 6000 121 6050 122 123 6100 124 125 6150 126 6200 127 128 6250 129 130 6300 131 132 6350 133 6400 134 135 6450 136 137 6500 138 6600 139 140 6700 141 142 6800 143 6900 144 145 7000 146 147 7100 148 7200 149 150 7300 DMX Value Function 151 152 7400 153 7500 154 155 7600 156 157 7700 158 7800 159 160 7900 161 162 8000 163 164 8100 165 8200 166 167 8300 168 169 8400 170 850...

Страница 28: ...9 102 103 106 107 110 111 114 115 118 119 122 123 126 127 130 DMX Value Color Value Color Macro 131 134 135 138 139 142 143 146 147 150 151 154 155 158 159 162 163 166 167 170 171 174 175 178 179 182 183 186 187 190 191 194 195 198 199 202 203 206 207 210 211 214 215 218 219 222 223 226 227 230 231 234 235 238 239 242 243 246 247 250 251 255 DMX Protocols 3 4 3 5 12 Channel Mode Color Macro ...

Страница 29: ...rotocols 1 3 Parameter ID Discovery command SET command GET command DISC_UNIQUE_BRANCH YES DISC_MUTE YES DISC_UN_MUTE YES DEVICE_INFO YES SUPPORTED_PARAMETERS YES SOFTWARE_VERSION_LABEL YES DMX_START_ADDRESS YES YES IDENTIFY_DEVICE YES YES DEVICE_MODEL_DESCRIPTION YES MANUFACTURER_LABEL YES DEVICE_LABEL YES YES SENSOR_DEFINITION YES SENSOR_VALUE YES DMX_PERSONALITY YES YES DMX_PERSONALITY_DESCRIPT...

Страница 30: ...f there is no number the default is 001 4 Software Version Label M0E v1 10 v5 27 180928 Software version Disable 5 DMX Personality 1 Ch Mode DMX channel mode and color temperature setting Enable See Table 1 6 DMX Start Address 1 DMX address Enable 1 512 Range 7 Device Hours N A N A Display only no actual response 8 Lamp Hours N A N A Display only no actual response 9 Lamp State N A N A Display onl...

Страница 31: ... Color Temperature RGBALC 1 Ch Mode 1 Ch Mode 3 Ch Mode 3 Ch Mode 5 Ch Mode 5 Ch Mode 12 Ch Mode 12 Ch Mode 1 Ch 2000K 1 Ch Mode 2000K Color Temperature 1 Ch 2500K 1 Ch Mode 2500K Color Temperature 1 Ch 2900K 1 Ch Mode 2900K Color Temperature 1 Ch 3200K 1 Ch Mode 3200K Color Temperature 1 Ch 4000K 1 Ch Mode 4000K Color Temperature 1 Ch 5000K 1 Ch Mode 5000K Color Temperature 1 Ch 5600K 1 Ch Mode 5...

Страница 32: ... Tel 82 2 6317 0464 Fax 82 2 2039 0464 E mail hello alpha lite net Web www alpha lite net 2 4 Floor 5 8 Gyeongin ro 88 gil Yeongdeungpo gu Seoul Republic of Korea 07363 ALPHA LITE USER MANUAL BOOK ...

Отзывы: