Package 4:
●
Documents (manuals, ERP data and label)
●
Installation instructions
●
2 x name plates
Package 5:
●
1 tube lubricant
●
1 protective cover for plug
●
4 EPP screws
● 3 flat seals 5/4"
● 4 flat seals for connection line
In façade package:
●
2 screws M5x16, black for the front wall
●
15 screws for façade mounting
●
1 plastic louvre grille
●
1 heat pump blind cover
●
1 EPP switch box cover
●
Blind cover for front wall
5.2 Storage
►
Where possible do not unpack the unit until
directly before installation.
►
Store unit protected against:
●
Moisture/damp
●
Frost
●
Dust and dirt
5.3 Unpacking and transport
Notes on safe transport
The unit is heavy (
“Technical data / Scope of
supply”, page 23). There is a risk of injuries or
damage to property if the unit falls or overturns.
There is a risk of cutting your hands on sharp edges
of the unit.
►
Wear cut resistant protective gloves.
The hydraulic connections are not designed for
mechanical loads.
►
Do not lift or transport the unit by the hydraulic
connections.
►
Transport the unit preferably with a pallet truck, al-
ternatively with a handcart or by carrying
►
Do not tilt the heat pump module by more than 45°.
WARNING
Do not transport heat pumps and compact
modules on top of one another in unpacked
condition - risk of toppling!
►
It is only permitted to use the lashing straps on the
heat pump module when carrying by hand.
Transport with a pallet truck
►
Transport the unit to the place of installation
packaged and secured on a wooden pallet.
Unpacking:
1.
Remove plastic films. Ensure that you do not
damage the unit.
2. Dispose of the transport and packaging material
in an environmentally friendly way and in
accordance with local regulations.
3.
Remove the film from the plastic element of the
front panel in the place of installation.
Lift the housing walls off the pallet and set
down
The heat pump comprises the heat pump module and
the compact module. These are placed on top of one
another on the pallet.
If the unit is not transported by a pallet truck: Do not lift
off the pallet until after unpacking and setting down the
housing panels.
●
The façade front is located in front of the device,
along with the accessory package.
●
The single-part and two-part side wall are located
on the rear side
Optional disconnection of the fan module
NOTE
If required (tight accessways), the fan module
can be removed.
1. Disconnect the plug-in connection of the load and
bus cable at the top left on the refrigerant circuit
switch box.
2. Remove the 4 screws.
3. Remove the fan module and set it down safely.